NET$MGMT_HELP.HLB  —  actions  Load  MOP  Client
    Initiates a downline load from the node you are managing to
    a target client system.

    The required arguments for this load operation are:

     o  Address

        The LAN address of the target node on circuit named in the circuit
        argument.

     o  Circuit

        The MOP circuit over which the load operation is to occur.

     The optional arguments for this load operation are:

     o  Management Image

        A file containing initialization data for the node; data is
        encoded in a product-specific format. (Also see the script file
        argument.) This argument may be required by the target system.

     o  Script File

        A file containing initialization data for the node; data is
        encoded as a sequence of network management commands in CMIP
        form. (Also see the management image argument.) This argument may
        be required by the target system.

     o  Secondary Loader

        Specifies the name of a second file containing the software to
        be downline loaded. This argument may be required by the target
        system.

     o  System Image

        Specifies the file containing the system image to be downline
        loaded. This argument is required for LAN circuits. If you do not
        supply this information as an argument for this command, you must
        specify a client set of parameters to provide this data. See the
        client argument.

     o  Tertiary Loader

        Specifies the name of a third file containing the software to
        be downline loaded. This argument may be required by the target
        system.

     o  Verification

        Is a hex string that must match a verification code at the receiving
        system in order to trigger the bootstrap mechanism so that the
        downline load can be performed.  The default is '0000000000000000'H,
        or %x00-00-00-00-00-00-00-00.

    Pressing the OK button will cause the load command to be executed and
    will return control back to the main window.

    Pressing the RESET button will cause all the arguments to be reset back
    to the state they were in when you first entered this display.

    Pressing the CANCEL button will return you to the main window.  No load
    command will be issued.
Close Help