ALTERNATE SPEED
Default: 0
Alternate low speed, in bits per second, to operate the line. You can
modify this characteristic only when the entity is disabled. This
characteristic is supported only when the characteristic communications
mode is asynchronous, the characteristic modem control is full,
the characteristic modem options includes rateselect, the
characteristic clock is internal, and when the alternate line speed
is needed.
CALL ACCEPT TIMER
Default: 0
Minimum time, in milliseconds, between the assertion of data set ready
and accepting a call by asserting request to send. This attribute is
maintained only if the characteristic modem control is set to none.
CARRIER LOSS TIMER
Default: 15000
Maximum time, in milliseconds, that the carrier detect signal can be
absent before the loss of carrier event is generated. This attribute
is not supported if the characteristic modem control is set to none.
CLOCK
Source of the transmit and receive clocks.
EXTERNAL - The modem provides the clock.
INTERNAL - The communications device provides the clock.
REFLECTED - The DTE transmit clock is a reflection of the DCE
transmit clock. This minimizes the clock to data skew that
the DCE encounters when high line speeds are used.
The default value depends on the setting of the characteristic
communications mode. If communications mode is asynchronous, the default
value of this characteristic is internal. Otherwise, the default value
is external.
The value of this attribute has no effect when the communications line is
in loopback mode. In this case, the type of loopback determines the type
of clock. This characteristic can only be modified when the entity is
disabled.
COMMUNICATIONS MODE
Default: Synchronous Value: Asynchronous or synchronous
Communications method to be used on the line. The value of this
characteristic is a copy of the communications mode argument specified
when the entity is created. You cannot modify this characteristic.
COMMUNICATIONS PORT
Default: None
Name of the communications port. The value of this characteristic is a
copy of the communications port argument specified when the entity is
created.
DUPLEX
Default: Full Value: Full or half
Indicates whether the line is full- or half-duplex. The value of
this characteristic is a copy of the duplex argument specified when the
entity is created.
ENCODING
Default: Normal Value: Normal or nrzi
Encoding technique used on the line. This characteristic can only be
modified when the entity is disabled.
MAXIMUM DISABLE TRANSMIT TIMER
Default: 500 Value: 0--60000
Maximum time, in milliseconds, that clear to send can remain asserted
before the line is disconnected after request to send is deasserted.
This attribute is not supported if the characteristic modem control is
set to none.
MAXIMUM DSR DEASSERTION TIMER
Default: 5000 Value: 0--60000
Maximum time, in milliseconds, the entity will wait for data set ready
to be deasserted after it has deasserted data terminal ready. If this
timer expires, the entity assumes it can assert data terminal ready once
again. This attribute is not supported if the characteristic modem
control is set to none.
MAXIMUM ENABLE TRANSMIT TIMER
Default: 2000 Value: 1--5000
Maximum time, in milliseconds, between the assertion of the request to
send signal and receiving the assertion of the clear to send signal. This
attribute is not supported if the characteristic modem control is set to
none.
MINIMUM DTR DEASSERTION TIMER
Default: 1000 Value: 0--60000
Minimum time, in milliseconds, that the DTE will deassert data terminal
ready during a disconnection. This attribute is not supported if the
characteristic modem control is set to none.
MODEM CONTROL
Default: Full Value: Full or none
Indicates whether the interchange circuits are to be monitored and used.
The value none means that only the data leads are monitored.
The value full must be used when the value of the characteristic
duplex is half. This characteristic is supported only if the
characteristic connection type is switched.
MODEM OPTIONS
Default: No options Value: Set of options
Set of values that determine the capabilities of the modem.
RATE SELECT - The modem is capable of data rate selection.
PROFILE
Default: None
Name of the local profile to be used with the line. This profile is used
to restrict the range of various line attributes, and to change the
defaults for those attributes. The value of this characteristic is a
copy of the profile argument specified when the entity is created.
RATE SELECT
Default: High Value: High or low
Specifies which of the line rates is to be used if none is specified
when a call is set up.
HIGH - The value of the speed characteristic is used.
LOW - The value of the alternate speed characteristic is used.
This characteristic is supported only if the characteristic modem
control is full, and if the characteristic modem options includes
rateselect.
SPEED
Default: 0
High speed, in bits per second, to be used on the line. This value is
always used on asynchronous links. It is used on synchronous links only
in the following circumstances:
When the value of the clock characteristic is internal.
When a null modem cable is detected.
When using a loopback mode that uses internal clocking.
SUCCESSFUL CALL INDICATION TIMER
Default: 30
Maximum time, in seconds, that the entity will wait for indication of a
successful call before disconnecting the line. This attribute is not
supported if the characteristic modem control is set to none.
SUPPRESS TEST INDICATOR
Default: False Value: True or false
Specifies whether the test mode signal is to be monitored. If the value
is false, a change in the circuit will be monitored and will cause a
Test Indication event to be generated.
You should set this characteristic to true in cases where the
transitions of this signal are not produced by entering test mode, so
that this signal should be ignored.
TRANSMIT HOLDOFF TIMER
Default: 0
Necessary delay, in milliseconds, between the transmitter being disabled
and then reenabled. The value 0 means that the request to send signal
can be asserted as soon as the client requests it.
This attribute is not supported if the characteristic modem control is
set to none.