The optional Format argument is an octet (00-FF) which specifies
the value of each byte in the test data. The default results in
alternating 0 and 1 bits (55).
test [node node-id] mop client client-name -
format octet [,optional arguments...]
If an Address and Circuit are not supplied by the MOP client
database, then that information must be provided in the command:
test [node node-id] mop client client-name -
circuit circuit-name, -
address lan-address, -
format octet [,optional arguments...]
Examples:
test mop client lamchp - ! Client gives Address and Circuit
format FF
test mop client lamchp, - ! Client gives default Circuit
address aa-00-04-00-34-56, format 00