o known clients only
Default: False Value: True or False
Specifies whether MOP attempts to service load requests from
remote systems which do not have a corresponding client entity.
Some network servers are designed to request specific software
by name, and in such a case there is no need for a client entity
to exist. By default, MOP tries to process requests for named
software from unknown clients. Set this attribute to true if you
wish MOP to ignore such requests.
o link name
Default: No name Value: Data Link entity name
Name of a station entity in the Data Link layer module indicated
by the type characteristic. This name is passed to the Data Link
layer module when MOP opens a portal for the circuit.
o retransmit timer
Default: 4 Value: 1-30
Time (in seconds) to wait for a response before retransmitting a
MOP protocol message.
o type
Specifies the circuit type. This characteristic is set when the
circuit is created (see the create command). The possible types
are CSMA-CD, FDDI, HDLC (Tru64 UNIX loop only), DDCMP (OpenVMS VAX
only), and LAPB (OpenVMS only). You cannot modify this
characteristic.