o catch all filter
Default: Pass Value: Block or pass
Action to take if neither the specific filter nor the global
filter contains an entry that matches an event.
block Discard the event.
pass Report the event.
o connect retry timer
Default: 120 Value: 0-65535
Number of seconds to wait after a disconnect or connection reject
before reattempting a connection. Connection attempts continue
until a connection is made or until the connect timer enabled
attribute is set to false or the outbound stream is disabled.
If the outbound stream is already connected to the sink when
the timer expires, no connection is attempted at that time. The
timer resets and connection attempts continue whenever the timer
expires.
o connect timer enabled
Default: True Value: True or false
Specifies whether the connect timer is operational (see connect
retry timer).
o disconnect timer
Default: 0; see Value: 0-4294967295
following description
Number of seconds to wait before disconnecting an idle
connection. Zero indicates that there is no disconnect timer
and connections are never automatically disconnected.
o global filter
Current global filter as it has been constructed by block,
ignore, and pass commands for this stream. By default, the
global filter is set to block all events for the following
entities: event dispatcher, event dispatcher sink, and event
dispatcher sink inbound stream and to pass all events for the
event dispatcher outbound stream entity.
o sink address
Default: No address Value: Sink address tower set
Sink address tower for this stream. Modifying this characteristic
affects only subsequent connect requests; existing connections
are unaffected.
o sink end user
Default: Number = 82 Value: End-user specification
Sink session control end user specification for this stream.
o sink node
Default: Local node Value: Full-name
Full DNS node name of the sink for this stream. Modifying this
characteristic affects only subsequent connect requests; existing
connections are unaffected. This fullname is used in combination
with the sink end user characteristic to establish the sink
connection.
o sink object
Default: No sink object Value: Full-name
Full DNS object name of the sink for this stream. Modifying this
characteristic affects only subsequent connect requests; existing
connections are unaffected. This fullname should match the object
name characteristic of the target sink.
o specific filter
Default: No specific filter
Current specific filter for this stream.
o template (Tru64 UNIX)
Default: No template Value: Simple name
Transport template (see osi transport template) for this stream's
connections.