MSA_UTIL_HELP.HLB  —  SET  UNIT  Qualifiers  /MIGRATE
             Migrates the fault tolerance (RAID) level or Stripe size or both
             of an existing logical unit. When migrating a unit with other units
             present on the same set of drives, some units may undergo volume
             expansion.

             Format:
                     SET UNIT <Unit_n>/MIGRATE [/RAID_LEVEL=R] [/STRIPE_SIZE=S]

                     where Unit_n = (0-31)
                           R=(0,1,5)
                           S=(8,16,32,64,128,256)

             Note:
                   - /ADG or /JBOD can also be used instead of /RAID_LEVEL

                   - Only RAID level and Stripe size can be modified using
                     the /MIGRATE qualifier

                   - Cannot migrate any RAID units (RAID 1, RAID 5 and so on)
                     that have spare disks to RAID 0 or JBOD units.
Close Help