Five macros are provided for locking pages into a working set.
These macros reside in SYS$LIBRARY:LIB.MLB. For a description
of how to use these macros, see the HP OpenVMS MACRO Compiler
Porting and User's Guide.
Three macros are used for image initialization-time lockdown, and
two macros are used for on-the-fly lockdown.
NOTE
If the code is being locked because the IPL will be raised
above 2, where page faults cannot occur, make sure that
the delimited code does not call run-time library or other
procedures. The VAX MACRO compiler generates calls to
routines to emulate certain VAX instructions. An image that
uses these macros must link against the system base image so
that references to these routines are resolved by code in a
nonpageable executive image.
Additional Information:
explode
extract