This example shows how to start the OCLAs on the system. The following commands load the OCLA Execlet, enable the OCLAs on each CPU in the system, and start each OCLA. At this point, the EV7 OCLAs are collecting data for each PC instruction executed by the active CPUs in the system. In the unlikely event of a system failure, PC values recorded by the OCLAs are stored in the system dump file and can later be retrieved by using the System Dump Analyzer (SDA). SDA> OCLA LOAD OCLA$PCTRACE load status = 00000001 SDA> OCLA ENABLE/RESET OCLA PC tracing enabled for 8 CPUs SDA> OCLA START OCLA PC tracing started for 8 CPUs