Invokes the MACRO-64 Assembler for OpenVMS Alpha Systems. MACRO-64
is an assembly language for programming Alpha computers.
Source programs written in MACRO-64 are translated into object
(or binary) code by the MACRO-64 Assembler, which produces an
object module and, optionally, a listing file.
NOTE
The MACRO-64 product does not ship with the OpenVMS
operating system. (Only this help file and the DCL
command are included in the base system.) You must
install MACRO-64 from the Freeware CD-ROM.
To invoke MACRO-64, enter the MACRO command and the /ALPHA
command-line qualifier, using the following syntax:
MACRO/ALPHA file-spec[, . . . ]
You must specify the /ALPHA command-line qualifier
before any other command-line parameters, qualifiers, or file
specifications.
If you do not specify a file type for an input file, the
assembler uses the default file type of .M64.
You can specify one or more source files to be assembled. To
assemble files individually, separate the file specifications
with commas. To concatenate and assemble the files as a single
input file, separate the file specifications with plus signs
(+).
Command-line qualifiers control special assembler options.
Assembler options can apply to the entire MACRO/ALPHA
command-line, or to the individual file being assembled. When
the qualifier follows the MACRO/ALPHA command, it applies
to all files listed. For more information on qualifiers, see the
Qualifiers on-line help section.
1 – Qualifiers
1.1 /ALIGNMENT=option
The full command-line option is /[NO]ALIGNMENT=option.
Controls the alignment of code and data. Valid options are:
Option Function
CODE Alignment of certain branch target labels.
DATA Natural alignment of data items.
If you omit the qualifier from the command line, the default
options are /NOALIGNMENT=(CODE, DATA). If more than one option
is specified, the options must be enclosed in parentheses and
separated by a comma.
1.2 /ARCHITECTURE=option
Determines which instructions are legal.
Option Function
GENERIC All instructions are allowed; equivalent to EV4.
HOST Instruction set is that of the host processor.
EV4 Instruction set is that of the EV4 base design processors
(21064, 20164A, 21066, and 21068 chips).
EV5 Instruction set is that of the EV5 processor
(some 21164 chips).
EV56 Instruction set is that of the EV56 processors
(some 21164 chips). Includes BWX extensions.
PCA56 Instruction set is that of the PCA56 processor
(21164PC chips). Includes BWX and MAX extensions.
EV6 Instruction set is that of the EV6 processor
(21264 chips). Includes BWX and MAX extensions and
SQRT instructions.
1.3 /DEBUG[=(options)]
The full command-line option is /[NO]DEBUG[=(options)].
Specifies DEBUG support. Valid options are:
Option Function
SYMBOL Generates debug symbol information.
TRACEBACKGenerates traceback information.
ALL Generates all previous debug information.
NONE Generates no debug information.
The default qualifier is /NODEBUG. When you specify /DEBUG with
no options, the default option is /DEBUG=ALL.
1.4 /DEFINE=(symbol_[=[=]value],...)
The full command-line option is /[NO]DEFINE=(symbol [=
[=]value],...).
Performs the same function as direct symbol assignment in your
source program. That is, the /DEFINE qualifier defines a numeric
symbol.
The Digital Command Language (DCL) converts all input to
uppercase unless you enclose it within quotation marks.
Use a single equal sign between the symbol and the value to
define a local symbol. Use two equal signs between the symbol and
the value to define a global symbol. The final value of a global
symbol is output to the object module and is available during
the linking process. A local symbol is only available during the
assembly process.
You cannot define a lexical string symbol with /DEFINE. The value
you specify for a symbol must be an integer literal. You can
specify this value using a binary, octal, decimal, or hexadecimal
radix. The default radix is decimal. If you specify an alternate
radix, you must use MACRO-64 radix syntax, not DCL radix syntax.
If you do not specify a value for the symbol, it defaults to 1.
The simplest form of a /DEFINE definition is as follows:
/DEFINE=TRUE
This definition is equivalent to the following definition:
TRUE=1
You can also specify more than one symbol definition as with the
following command:
/DEFINE=(CHIP==21064,UNROLL=4)
This definition is equivalent to the following definitions:
CHIP==21064
UNROLL=4
When more than one /DEFINE qualifier is present on the MACRO
command line or in a single assembly unit, the assembler uses
only the last one.
The default qualifier is /NODEFINE.
1.5 /DIAGNOSTIC[=file-spec]
The full command-line option is /[NO]DIAGNOSTIC[=file-spec].
Controls whether diagnostics are created and stored in the
specified optional file. If a file specification is not supplied,
the assembler creates a diagnostic file using the same name
as the source file. For example, if you use a source file
named XXX.M64, the assembler creates a diagnostic file named
XXX.DIA. You can use the diagnostic file with other Digital
layered products including, but not limited to, the DEC Language-
Sensitive Editor (LSE).
The default qualifier is /NODIAGNOSTIC.
1.6 /ENVIRONMENT=[NO]FLOAT
The full command-line option is /ENVIRONMENT=[NO]FLOAT.
Controls whether the assembler generates floating-point
instructions when optimizing code and performing code-label
alignment.
Currently, the only floating-point instruction generated by
the assembler during optimization and alignment processing
is FNOP, the floating-point no-operation instruction. If you
specify /ENVIRONMENT=NOFLOAT, the assembler does not generate any
floating-point instructions as part of optimization and alignment
processing. Floating-point instructions that you specify in your
source program are unaffected.
1.7 /LIBRARY
The full command-line option is /LIBRARY[=file-spec].
Searches macro libraries in the following order:
1. The library designated by the /LIBRARY qualifier.
2. The .LIBRARY directives.
3. The MACRO64.MLB library. The assembler searches for the
MACRO64.MLB macro library in the following locations:
MACRO64$LIBRARY, ALPHA$LIBRARY, and finally SYS$LIBRARY.
4. The STARLET.MLB library. The assembler searches for the
STARLET.MLB macro library in the following locations:
MACRO64$LIBRARY, ALPHA$LIBRARY, and finally SYS$LIBRARY.
In addition, you can place the macro library definitions in the
listing file by using the command-line qualifier /SHOW=LIBRARY.
1.8 /LIST[=file-spec]
The full command-line option is /[NO]LIST[=file-spec].
Controls whether a listing is created and optionally provides
an output file specification for the listing file. Do not use
wildcard characters in this file specification.
If you enter the MACRO/ALPHA command interactively, the
default qualifier is /NOLIST. The assembler sends output to
the current output device rather than to a listing file. If you
execute the MACRO/ALPHA command in a batch job, the default
qualifier is /LIST.
If you do not specify a file specification, the assembler creates
a listing file using the same name as the source file. For
example, if you use a source file named XXX.M64, the assembler
creates a listing file named XXX.LIS.
1.9 /MACHINE_CODE
The full command-line option is /[NO]MACHINE_CODE.
Produces a binary machine code listing after the source text if a
listing file is requested. The default qualifier is /NOMACHINE_
CODE.
1.10 /NAMES=case_option
The full command-line option is /NAMES=case_option.
Specifies the alphabetic casing of identifiers in source code
statements. Valid options are:
Option Function
UPPER_ Converts all identifiers to upper alphabetic case.
CASE
LOWER_ Converts all identifiers to lower alphabetic case.
CASE
AS_IS Causes all identifiers to remain in the case used in
source statements.
If you use the /NAMES qualifier in a command line, you must
supply a case_option. If you omit the qualifier from the command
line, the default option is /NAMES=UPPER_CASE.
1.11 /OBJECT[=file-spec]
The full command-line option is /[NO]OBJECT[=file-spec].
Controls whether an object file is created and optionally
provides a file specification. Do not use wildcard characters
in this file specification.
If you do not specify a file specification, the assembler creates
an object file using the same name as the source file. For
example, if you use a source file named XXX.M64, the assembler
creates an object file named XXX.OBJ.
The default qualifier is /OBJECT.
1.12 /OPTIMIZE[=(option-list)]
The full command-line option is /[NO]OPTIMIZE[=(option-list)].
Specifies optional assembler optimizations. Valid items in the
option-list are:
Option Function
SCHEDULE Specifies instruction scheduling.
PEEPHOLE Specifies peepholing.
Specifying /OPTIMIZE with no options is the same as specifying
/OPTIMIZE=(PEEPHOLE,SCHEDULE).
The default qualifier is /NOOPTIMIZE.
1.13 /PREPROCESSOR_ONLY_[=filespec]
\BK_ADDED_27)
The full command-line option is /PREPROCESSOR_ONLY [=filespec]).
Causes the assembler to output a source file that is the result
of the input source file after preprocessing. Suppresses
diagnostic messages and does not produce diagnostic (.ANA) or
object (.OBJ) files.
The default option, /NOPREPROCESSOR_ONLY-MACRO-64, assembles your
source files normally.
If you specify /PREPROCESSOR_ONLY without a file specification
argument, the output file name defaults to the name of the
primary source input file. The output file type defaults to .ASM.
The following MACRO-64 directives are executed by the
preprocessor and screened from the preprocessor output file:
.DISABLE PREPROCESSOR_OUTPUT
.ENABLE PREPROCESSOR_OUTPUT
.IF
.ELSE
.ENDC
.IIF
.IF_FALSE
.IF_TRUE
.IF_TRUE_FALSE
.INCLUDE
.LIBRARY
.IRP
.IRPC
.REPEAT
.ENDR
.MACRO
.ENDM
.MCALL
.MDELETE
.MEXIT
.NARG
.NCHR
Include files are inserted in place of the .INCLUDE directive
into the preprocessor output file.
Macro definitions and repeat block definitions are screened from
the preprocessor output file.
Macro expansion lines and repeat block expansion lines are
inserted in place of the macro invocation line or repeat block,
respectively, into the preprocessor output file.
Lexical string-symbol assignment statements are screened from the
preprocessor output file.
Lines containing lexical operators are replaced with their
equivalents after lexical operator processing.
Lexical line continuations are processed into a single,
uncontinued line.
All other language elements, including directives not previously
listed, label definitions, direct numeric-symbol assignments, and
so forth are passed through unchanged to the preprocessor output
file.
1.14 /SHOW=(item,...)
The full command-line option is /[NO]SHOW=(item,...).
Modifies the output listing file. This qualifier is meaningful
only when /LIST is specified. Valid items are:
Option Function
BINARY Lists macro expansions that generate binary code.
BINARY is a subset of EXPANSIONS.
CONDITIONALS Shows sections of code conditionally skipped.
EXPANSIONS Shows macro expansions.
INCLUDE Shows all .INCLUDE files.
LIBRARY Shows macro library modules.
The default option is /SHOW=CONDITIONALS.
1.15 /WARNINGS=(option-list)
The full command-line option is /[NO]WARNINGS=(option-list).
Controls the severity level of messages and diagnostics. Valid
options are:
Option Function
WARNINGS Display/suppress warnings.
INFORMATIONALS Display/suppress informationals.
ALL Display/suppress warnings and informationals.
NONE Display/suppress nothing.
The default options are /WARNINGS=(WARNINGS,INFORMATIONALS). If
more than one option is specified, options must be enclosed in
parentheses separated by a comma.
2 – Source Statement Format
MACRO-64 source statements can have a maximum of four fields, as
follows:
o Label field-Symbolically defines a location in a program.
o Operator field-Specifies the action to be performed by the
statement; this can be an instruction, an assembler directive,
or a macro call.
o Operand field-Contains the instruction operands or the
assembler directive arguments or the macro arguments.
o Comment field-Contains a comment that explains the meaning of
the statement; this does not affect program execution.
You can separate statement fields by either a space or a tab
stop, but Digital recommends that you format statements with the
Tab key to ensure consistency and clarity.
Table 1 Using Tab Stops in Statement Fields
Column
in
Which
Field
Field Begins Tab Stops to Reach Column
Label 1 0
Operator 9 1
Operand 17 2
Comment 41 5
The following example shows a typical source statement:
EXP: .BLKL 50 ; Table stores expected values
Rules for Coding Source Statements
The following rules apply for coding source statements:
o You can continue a single statement on several lines by
using a hyphen (-) as the last nonblank character before
the comment field, or at the end of line (when there is no
comment).
o In most cases, you can continue a statement at any point. If a
symbol name is continued and the first character on the second
line is a tab or a blank, the symbol name is terminated at
that character.
o Blank lines are legal, but they have no significance in the
source program except that they terminate a continued line.
The following sections describe each of the statement fields in
detail.
2.1 – Label Field
A label is a user-defined symbol that identifies a location in
the program. The symbol is assigned a value equal to the location
counter where the label occurs. The following rules apply when
coding source statements with labels:
o If a statement contains a label, the label must be in the
first field on the line.
o The user-defined symbol name can be up to 31 characters long
and can contain any alphanumeric character, as well as the
underscore (_), dollar sign ($), and period (.) characters.
o If a label extends past column 7, Digital recommends you place
it on a line by itself so that the following operator field
can start in column 9 of the next line.
o A label is terminated by a colon (:) or a double colon (::).
In the following source statement, EXP: is the label field:
EXP: .BLKL 50 ; Table stores expected values
There are three types of labels:
o Global labels-Can be referenced by other object modules and
are defined using a double colon (::).
o Local labels-Can be referenced only within the current module
and are defined using a single colon (:).
o Temporary labels-Can be referenced only within the bounds
of either two local labels, two global labels, two psects
(program sections), or within the bounds of a temporary
label scope, as defined by .ENABLE LOCAL_BLOCK and
.DISABLE LOCAL_BLOCK. Temporary labels are defined using one
to five digits followed by a dollar sign and a single colon
($:).
The following example shows how these labels appear in use:
EXP: .BLKL 50 ; EXP is a local label used to
; identify a 50-word block of storage
DATA:: .BLKW 25 ; DATA is a global label used to
; identify a 25-word block of storage
10$: .BLKW 5 ; 10$ is a temporary label used to
; identify a five word block of
; storage.
2.2 – Operator Field
The operator field specifies the action to be performed by the
statement. This field can contain an instruction, an assembler
directive, or a macro call. If the operator is:
o An instruction, MACRO-64 generates the binary code for that
instruction in the object module.
o A directive, MACRO-64 performs certain control actions or
processing operations during source program assembly.
o A macro call, MACRO-64 expands the macro.
Use either a space or a tab stop to terminate the operator
field; however, Digital recommends that you use the tab stop
to terminate the operator field.
In the following source statement, .BLKL is the operator field:
EXP: .BLKL 50 ; Table stores expected values
2.3 – Operand Field
The operand field can contain operands for instructions or
arguments for either assembler directives or macro calls.
Operands for instructions identify the memory locations or the
registers that are used by the machine operation. The operand
field for a specific instruction must contain the correct number
and type of operands required by that instruction.
Arguments for a directive must meet the format requirements of
that directive.
Operands for a macro must meet the requirements specified in the
macro definition.
Use a comma (,) to separate operands for instructions and
directives.
The semicolon that starts the comment field terminates the
operand field. If a line does not have a comment field, the
operand field is terminated by the end of the line.
In the following source statement example, 50 is the operand
field supplied to the operator field, .BLKL:
EXP: .BLKL 50 ; Table stores expected values
2.4 – Comment Field
The comment field contains text that explains the function of the
statement. You can use comments to describe algorithms, reasons
for selecting particular methods, and parameters passed to
routines. Comments do not affect assembly processing or program
execution.
The comment field must be preceded by a semicolon (;) and can
contain any printable ASCII character. It is terminated by the
end of the line.
A comment can appear on a line by itself. If a comment does
not fit on one line, it can be continued on the next, but the
continuation must be preceded by another semicolon.
In the following source statement example, "Table stores expected
values" is the comment field. Note that the comment field begins
with a semicolon.
EXP: .BLKL 50 ; Table stores expected values
3 – Character Set
When coding source statements, you need to be aware of what
characters are acceptable to the assembler, and how the assembler
interprets them. The following numbers and characters are
accepted by the assembler:
o The letters of the alphabet, A to Z, uppercase and lowercase.
By default, the assembler converts all lowercase letters
to uppercase. This means it considers lowercase letters
equivalent to uppercase letters.
The assembler can operate in a case-sensitive mode. In case-
sensitive mode, the assembler does not convert lowercase
letters to uppercase letters. On OpenVMS and OpenVMS Alpha
systems, you can select case-sensitive mode from the command
line with the /NAMES=AS_IS qualifier.
o The digits 0 to 9.
o The special characters listed in the Special Characters Table
which follows.
Table 2 Special Characters Used in MACRO-64 Statements
Character
CharactName Function
_ Underscore Character in symbol names.
$ Dollar Character in symbol names.
sign
. Period Character in symbol names, current location
counter, and decimal point.
: Colon Local label terminator.
:: Double Global label terminator.
colon
sign keyword argument terminator.
equal
sign
# Number Literal value indicator.
sign
@ At sign Arithmetic shift operator.
; Semicolon Comment field indicator.
+ Plus Unary plus operator and arithmetic addition
sign operator.
- Minus Unary minus operator, arithmetic subtraction
sign or operator, and line continuation indicator.
hyphen
* Asterisk Arithmetic multiplication operator.
/ Slash Arithmetic division operator.
& Ampersand Logical AND operator.
! ExclamationLogical inclusive OR operator.
point
\ Backslash Logical exclusive OR and numeric conversion
indicator in macro arguments.
^ Circumflex Unary operators and macro argument
delimiter.
( ) ParenthesesDisplacement and register field delimiter in
an instruction operand. Argument delimiter
to a lexical operator.
<> Angle Argument or expression grouping delimiters.
brackets
? Question Created local label indicator in macro
mark arguments.
' Apostrophe Macro argument concatenation indicator.
" Double Quoted literal delimiter.
quote
% Percent Delimits the beginning of a lexical
sign operator.
(space)Space or Separates source statement fields. Spaces
tab within expressions are otherwise ignored.
(tab)
, Comma Separates symbolic arguments within the
operand field. Multiple expressions in the
operand field must be separated by commas.
4 – Numbers
Numbers can be integers or floating-point numbers. The following
sections describe these types of numbers.
4.1 – Integers
You can use integers in any expression, including expressions in
operands and in direct assignment statements.
FORMAT
snn
s
An optional sign: plus sign (+) for positive numbers (the
default), or minus sign (-) for negative numbers.
nn
A string of numeric characters that is legal for the specified
radix.
MACRO-64 interprets all integers in the source program as decimal
unless the number is preceded by a radix control operator.
Integers must be in the range of -263 to +263 -1 for signed data
or in the range of 0 to 264 -1 for unsigned data.
Negative numbers must be preceded by a minus sign; MACRO-64
translates such numbers into two's complement form. In positive
numbers, the plus sign is optional.
4.2 – Floating Point Number
You can use a floating-point number in the .DOUBLE, .FLOAT,
.F_FLOATING, .D_FLOATING, .G_FLOATING, .S_FLOATING, and
.T_FLOATING directives. You cannot use a floating-point number
in an expression or with a unary or binary operator except the
unary plus and unary minus.
You can specify a floating-point number with or without an
exponent.
FORMAT
Floating-point number without exponent:
snn
snn.nn
snn.
Floating-point number with exponent (E):
snnEsnn
snn.nnEsnn
snn.Esnn
s
An optional sign.
nn
A string of decimal digits in the range of 0 to 9.
The decimal point can appear anywhere to the right of the first
digit. A floating-point number cannot start with a decimal point
because MACRO-64 treats the number as a user-defined symbol.
5 – Quoted Literals
A quoted literal is a string of characters enclosed in double
quotes (" "). Use the following guidelines when specifying
characters in a quoted literal:
o Any character except null, carriage return, and form feed can
appear within the string.
o To include a double quote or backslash in a string, you must
precede it with a backslash (\).
o To specify an arbitrary character, you can specify "\xhh",
where each h represents a single hexadecimal digit. For
example:
"AB\\CD\"EF\x47"
This string contains the following characters:
AB\CD"EFG
Also note that the assembler does not convert the case of
alphabetic characters within a quoted literal.
Quoted literals can be continued over several lines. Use the
hyphen (-) as the line continuation character and delimit the
string with double quotes. For example:
.ASCII "Strings are delimited with double quotes."
.ASCII "The backslash is an escape character."
.ASCII "Strings can be continued onto multiple lines -
just as any other line."
.ASCII "Use two backslashes (\\) to represent -
the back-slash itself."
.ASCII "Hexidecimal escape sequences use -
lower or upper X: \x00 or \X00"
.ASCII "Precede a double quote with a backslash (\") -
to embed the quote."
6 – Symbols
You use symbols in MACRO-64 source statements to represent an
instruction, directive, register name, or value. You can use four
types of symbols in MACRO-64 source programs: permanent symbols,
predefined symbols, user-defined symbols, and macro names.
6.1 – Permanent Symbols
Permanent symbols consist of MACRO-64 directives and instruction
mnemonics. You need not define directives before you use them in
the operator field of a MACRO-64 source statement. It is also not
necessary to define instruction mnemonics before using them in
the instruction statements.
6.2 – Predefined Symbols
Predefined symbols are MACRO-64 register symbols that are not
permanently reserved. You can delete the definition of any of
these predefined register symbols. You can also define your own
register symbols.
You can express the 32 general registers and the 32 floating-
point registers of the Alpha processor in a source program as
follows:
Register
Name Description
R0 General register 0.
R1 General register 1.
. .
. .
. .
R29 General register 29 or frame pointer. If you use R29 as a
or FP frame pointer, Digital recommends you use the name FP. If
you use R29 as a general register, Digital recommends you
use the name R29.
R30 General register 30 or stack pointer. If you use R30 as a
or stack pointer, the name SP is recommended; if you use R30
SP as a general register, the name R30 is recommended.
R31 General register 31.
F0 Floating-point register 0.
. .
. .
. .
F31 Floating-point register 31.
NOTE
When MACRO-64 operates in /NAMES=AS_IS mode, all of the
previous register symbols are defined in all uppercase and
all lowercase.
To define your own register symbols, use either the .DEFINE_
FREG or .DEFINE_IREG directive for floating-point or integer
registers, respectively. For more information about the .DEFINE_
FREG or .DEFINE_IREG directives, see .DEFINE_FREG and .DEFINE_
IREG, respectively.
You can delete a register symbol definition with the .UNDEFINE_
REG directive. For more information about the .UNDEFINE_REG
directive, see .UNDEFINE_REG.
While an identifier is defined as a register symbol, it can only
be used in those contexts that allow a register.
6.3 – User-Defined Symbols and Macro Names
You can use symbols to define labels, or you can equate them to a
specific value by a direct assignment statement. You can also use
these symbols in expressions.
Use the following rules to create user-defined symbols:
o Use alphanumeric characters, underscores (_), dollar signs
($), and periods (.). Any other character terminates the
symbol.
o The first character of a symbol cannot be a number.
o The symbol must be no more than 31 characters long and must be
unique.
o The symbol must not be a register name.
o The symbol cannot be one of the following conditional or macro
directives:
.ELSE .ENDC .ENDM
.ENDR .IF .IF_FALSE (.IFF)
.IF_TRUE .IF_TRUE_ .IIF
(.IFT) FALSE
(.IFTF)
.INCLUDE .IRP .IRPC
.LIBRARY .MACRO .MCALL
.MDELETE .MEXIT .NARG
.NCHAR .REPEAT
In addition, by Digital convention:
o The dollar sign ($) is reserved for names defined by Digital.
This convention ensures that a user-defined name (that does
not have a dollar sign) will not conflict with a Digital-
defined name (that does have a dollar sign).
o Do not use the period (.) in any global symbol name because
many languages, such as Fortran, do not allow periods in
symbol names.
Macro names follow the same rules and conventions as user-defined
symbols. User-defined symbols and macro names do not conflict;
that is, you can use the same name for a user-defined symbol and
a macro.
6.4 – Determining Symbol Values
The value of a symbol depends on its use in the program. MACRO-64
uses a different method to determine the values of symbols in the
operator field than it uses to determine the values of symbols in
the operand field.
6.5 – Using Symbols in the Operator Field
A symbol in the operator field can be either a permanent symbol
or a macro name. MACRO-64 searches for a symbol definition in the
following order:
1. Macro and conditional directives:
.ELSE .ENDC .ENDM
.ENDR .IF .IF_FALSE (.IFF)
.IF_TRUE .IF_TRUE_ .IIF
(.IFT) FALSE (.IFTF)
.INCLUDE .IRP .IRPC
.LIBRARY .MACRO .MCALL
.MDELETE .MEXIT .NARG
.NCHAR .REPEAT
2. Previously defined macro names
3. Permanent symbols (instructions and other directives)
This search order allows most permanent symbols, except
conditional directives and macro directives, to be redefined
as macro names. If a symbol in the operator field is not defined
as a macro or a permanent symbol, the assembler displays an error
message.
6.6 – Using Symbols in the Operand Field
A symbol in the operand field must be either a user-defined
numeric symbol, a label, or a register name.
User-defined numeric symbols and labels can be either local
(internal) symbols or global (external) symbols. Whether numeric
symbols and labels are local or global depends on their use in
the source program.
You can reference a local numeric symbol or label only in the
module in which it is defined. If local numeric symbols or labels
with the same names are defined in different modules, the symbols
and labels are completely independent. The definition of a global
numeric symbol or label, however, can be referenced from any
module in the program.
MACRO-64 treats all user-defined numeric symbols and labels as
local unless you explicitly declare them to be global by doing
one of the following:
o Use the double colon (::) in defining a label.
o Use the double equal sign (==) in a direct assignment
statement.
o Use the .WEAK directive.
You can only use user-defined lexical string symbols with the
lexical string operators. You can define a macro using the same
name as a previously defined local numeric symbol, global numeric
symbol, or a lexical string symbol. However, you cannot define a
lexical string symbol and a numeric symbol using the same name.
In addition, you cannot use the same name for both a local and
global numeric symbol. You cannot use the same symbol name for
both a numeric symbol (local or global) and a label (local or
global).
7 – Temporary Labels Within Source Code
Use temporary labels to identify addresses within a block of
source code.
Format
nnnnn$:
nnnnn
A decimal integer in the range of 1 to 65,535.
In most cases, you can use temporary labels in the same way
you use other labels that you define; however, there are some
differences:
o Temporary labels cannot be referenced outside the temporary
label block in which they are declared.
o Temporary labels can be redeclared in another block of source
code.
o Temporary labels that occur within a psect with the MIX or
NOMIX attribute do not appear in the debugger symbol table;
thus, they cannot be accessed by the symbolic debugger.
o Temporary labels cannot be used in the .END or
.PROCEDURE_DESCRIPTOR directives.
By convention, temporary labels are positioned like statement
labels: left-justified in the source text. Although temporary
labels can appear in the program in any order, by convention,
the temporary labels in any block of source code should be in
increasing numeric order.
Temporary labels are useful as branch addresses when you use
the address only within the block. You can use temporary labels
to distinguish between addresses that are referenced only in a
small block of code and addresses that are referenced elsewhere
in the module. A disadvantage of temporary labels is that their
numeric names do not provide any indication of their purpose.
Consequently, you should not use temporary labels to label
sequences of statements that are logically unrelated; you should
use user-defined symbols instead.
Digital recommends that users create temporary labels only in
the range of 0$ to 29999$ because the assembler automatically
creates temporary labels in the range of 30000$ to 65535$ for use
in macros.
The temporary label block in which a temporary label is valid is
delimited by the following statements:
o A user-defined label: global or local.
o A .PSECT directive.
An example showing the correct and incorrect use of temporary
labels follows:
A: ADDQ R1, R2, R3
BEQ R3, 2$ ; correct use
MULQ R2, R3, R4
2$: ADDQ R1, R4, R5 ; definition of temporary label
B: BNE R5, 2$ ; illegal
C: SUBQ R2, R4, R6
In this example, 2$ is a temporary label defined in the
block between A: and B:. The forward reference in the second
instruction is properly resolved. The line labeled B: also
references 2$, but the label B has already closed the range.
The temporary label 2$ can be used later in the program, but
its definition must appear within the same block as the label.
o The .ENABLE and .DISABLE directives, which can extend a local
label block beyond user-defined labels and .PSECT directives.
A temporary label block is usually delimited by two user-defined
labels. However, the .ENABLE LOCAL_BLOCK directive starts a local
block that is terminated by one of the following:
o A second .ENABLE LOCAL_BLOCK directive
o A .DISABLE LOCAL_BLOCK directive followed by a user-defined
label or a .PSECT directive
Temporary labels can be preserved with the context of the program
section in which they are defined for future reference. See the
descriptions of the .SAVE_PSECT [LOCAL_BLOCK] directive and the
.RESTORE_PSECT directive.
8 – Label Addresses
In the absence of optimization and automatic data alignment,
label addresses are defined to be the psect and offset of the
current location counter at the point where the label is defined.
When either optimization or automatic data alignment are enabled,
the following additional considerations apply.
8.1 – Label Addresses, Optimization, and Code Alignment
Optimization and code alignment can affect the addresses
assigned to labels defined in psects that have the EXE and NOMIX
attributes. Optimization and code alignment are disabled by
default, and can be enabled with the /OPTIMIZE and /ALIGNMENT
command-line qualifiers and the .ENABLE directive In general, the
assembler assigns the psect and offset of the current location
counter before optimization or alignment of code labels. However,
the assembler adjusts references to labels in branch instructions
to the address of the label after optimization and code alignment
processing. The assembler does not adjust references to labels
where the label reference occurs in an expression with more than
one term. The following example shows this:
.PSECT CODE, EXE, NOMIX
BSR R0, 10$ ; R0 -> 10$ (postoptimization)
10$: LDA R1, 20$-10$(R0) ; R1 -> 20$ (preoptimization)
JMP (R1)
[...]
20$:
In the previous example, the assembler adjusts the target
address of the BSR instruction to be the location of 10$ after
optimization and code alignment have taken place. Thus, the
branch to 10$ functions as expected. However, when processing the
LDA instruction, the assembler computes the offset between 20$
and 10$ before optimization and code alignment. Thus, the address
of 20$ that is stored in R1 is the address prior to optimization
and code alignment. Depending on the sequence of instructions
between 10$ and 20$, the address before optimization and code
alignment may differ from the address after optimization and code
alignment and the JMP instruction may not transfer control to the
expected address.
Note also that the assembler only performs postoptimization
adjustment of label addresses when the label is the only term
in the expression. For example:
.PSECT CODE, EXE, NOMIX
.BASE R27,LINKAGE
LDQ R26, ROUTINE1_ADDR
JSR R26, (R26)
LDQ R26, ROUTINE2_ADDR
JSR R26, (R26)
RET R28
NOP
NOP
ROUTINE1:
RET (R26)
ROUTINE2:
RET (R26)
.PSECT LINKAGE, NOEXE
LINKAGE:
ROUTINE1_ADDR:
.ADDRESS ROUTINE1
ROUTINE2_ADDR:
.ADDRESS ROUTINE2+0
In the previous example, the assembler adjusts the address stored
with the .ADDRESS ROUTINE1 directive to the address of label
ROUTINE1 after optimization and code alignment. However, since
the expression in the .ADDRESS ROUTINE2+0 directive is not a
single term, the assembler adds the offset 0 and the address
of ROUTINE2 before optimization and code alignment and stores
the result. Since the address stored is the address before
optimization and code alignment, the second JSR instruction may
not transfer control to the address that is expected.
8.2 – Label Addresses and Automatic Data Alignment
Automatic data alignment can affect the addresses assigned to
labels in psects that have the NOEXE or MIX attributes. Automatic
data alignment is enabled with the .ENABLE ALIGN_DATA directive
or the /ALIGNMENT=data command-line option.
A label that occurs in a statement with a data-storage directive
is assigned the psect and offset of the storage allocated by the
data-storage directive. If the data-storage directive requires
automatic alignment, the address is assigned to the label after
automatic alignment.
The same is true of labels that occur in statements by themselves
and that are followed by a data directive in a subsequent
statement. However, if a label occurs in a statement by itself
and is followed by a statement that is not a data-storage
directive, a macro directive, a conditional directive, or a
lexical-string symbol assignment, the label is assigned the psect
and offset of the current location counter before any automatic
alignment.
The assembler only assigns addresses to labels after alignment
under the conditions previously described and only with automatic
alignment. If you place a label before a .ALIGN directive that
manually aligns the current location counter, the assembler
assigns the address of the label before performing the manual
alignment. The following example shows the interaction of label
address assignment and automatic data alignment:
.ENABLE ALIGN_DATA
.PSECT DATA, NOEXE
.BYTE 1 ; The byte is stored in psect data at offset 0
A: .PRINT "Not aligned" ; Any non-macro, nonconditional
; statement, including this .PRINT directive
; prevents A from being automatically aligned
; -- A is assigned offset 1
B: ; B is automatically aligned to offset 4
C: .LONG 2 ; C is automatically aligned to offset 4
D: .ALIGN 0 ; The .ALIGN global directive prevents D
; from being automatically aligned --
; D is assigned offset 8
E: .OCTA 3 ; E is automatically aligned to offset 16
Automatic data alignment and label-address assignment can be an
important consideration when calculating the difference between
two labels. For example, consider the following macro, which
stores a string preceded by a word that contains the string's
length:
.MACRO VARYING_STRING STRING ?L1, ?L2
.WORD L2-L1
L1: .ASCII "STRING"
L2:
.ENDM VARYING_STRING
If an invocation of the VARYING_STRING macro is followed by a
data-storage directive that requires automatic alignment, the
VARYING_STRING macro will not store the correct string length.
For example:
.PSECT DATA, NOEXE, .OCTA
.ENABLE ALIGN_DATA
VARYING_STRING <Time for something sweet!> ; 25 bytes
F: .OCTA 4
In this example, the intention is to make the L2 label generated
by the VARYING_STRING macro be assigned the offset 27, 2 for
the .WORD directive, plus 25 for the .ASCII directive. Instead,
it is assigned the offset 32 along with the label F because
the .OCTA directive requires automatic alignment to offset 32.
Therefore, the string length is incorrectly stored as 30 rather
25. To make this macro work as desired, you must include, in the
macro definition, a macro directive that is not a data-storage,
macro, or conditional directive after the generated label L2. In
the following example, .ALIGN 0 is a good choice as it reflects
the idea that the preceding label is not aligned:
.MACRO VARYING_STRING STRING ?L1, ?L2
.WORD L2-L1
L1: .ASCII "STRING"
L2: .ALIGN 0
.ENDM VARYING_STRING
With this change, the generated label L2 is assigned the offset
27 before the assembler performs automatic data alignment for the
.OCTA directive. As a result, the VARYING_STRING macro works as
desired and stores the correct string length of 25.
9 – Terms and Expressions
A term can be any of the following:
o A number.
o A numeric symbol.
o A label.
o The current location counter.
o Any of the previously noted items preceded by a unary
operator.
MACRO-64 evaluates terms as quadword (8-byte) values. The current
location counter (.) has the value of the location counter at
the start of the current operand.
MACRO-64 considers unary operators part of a term and, thus,
performs the action indicated by a unary operator before it
performs the action indicated by a binary operator.
Expressions are combinations of terms joined by binary operators
and evaluated as quadword (8-byte) values. MACRO-64 evaluates
expressions from left to right with no operator precedence rules.
However, you can use angle brackets (<>) to change the order
of evaluation. Any part of an expression that is enclosed in
angle brackets is first evaluated to a single value, which is
then used in evaluating the complete expression. For example, the
expressions A*B+C and A*<B+C> are different. In the first case, A
and B are multiplied and then C is added to the product. In the
second case, B and C are added and the sum is multiplied by A.
You can also use angle brackets to apply a unary operator to an
entire expression, such as -<A+B>.
Expressions fall into four categories: relocatable, absolute,
external (global), and complex. You can determine the type of
expression by the following rules:
o An expression is relocatable if its value is fixed relative
to the start of the psect in which it appears. The current
location counter is relocatable in a relocatable psect.
o An expression is absolute if its value is an assembly-
time constant. An expression whose terms are all numbers
is absolute. An expression that consists of a relocatable
term minus another relocatable term from the same psect is
absolute, because such an expression reduces to an assembly-
time constant.
o An expression is external if it is not complex, and it
contains one or more symbols that are not defined in the
current module.
o An expression is complex if it contains a relocatable or
external term or subexpression that is operated upon by an
operator other than the plus sign (+) or the minus sign
(-). An expression is also complex if it contains more than
one term or subexpression that is relocatable or external.
An exception to this rule is the difference between two
relocatable subexpressions or terms where both relocatable
values occur in the same psect. In this case, the expression
is absolute.
Complex expressions are constrained to use the following form:
FORMAT
term operator term
term
Term is a relocatable or external subexpression.
operator
Operator is any of the MACRO-64 operators.
Neither term can itself be a complex subexpression. If you
specify a complex expression that does not match the correct
form, the assembler issues a diagnostic error message indicating
that the expression is too complex. Note also that the assembler
does not attempt to reorder expressions to make your expressions
match the correct form. For example, the following expression is
too complex:
.external E1, E2
.quad E1+5+E2+6 ; too complex
Because the assembler has no precedence rules, it attempts to
evaluate the previous expression as <<<E1+5>+E2>+6>. Since
<<E1+5>+E2> is itself a complex term, <<<E1+5>+E2>+6> does not
match the previous form and is too complex. However, you can
regroup the expression using angle brackets (<>) to match the
required form as follows:
.external E1, E2
.quad <E1+5>+<E2+6> ; legal complex expression
In this case, both <E1+5> and <E2+6> are simple, external terms.
Since none of the terms are complex, the expression matches the
correct form and the assembler accepts the complex expression.
You can use any type of expression in most MACRO-64 statements,
but restrictions are placed on expressions used in the following
contexts:
o .BASE directive.
o .BLKx storage allocation directives.
o .IF conditional assembly block directives.
o .REPEAT repeat block directives.
o Direct assignment statements.
o Lexical string operator arguments.
Expressions used in these contexts can contain only symbols or
labels that have been previously defined in the current module.
The .BASE directive accepts expressions that contain external
symbols previously declared with the .EXTERNAL directive. The
other contexts previously described cannot accept expressions
that contain external symbols. Symbols defined later in the
current module cannot be used in any of these contexts.
Expressions in the .IF conditional directives, .REPEAT
conditional directives, and lexical string operator arguments
are relocatable. However, expressions in the .BLKx directives
must be absolute.
Expressions cannot contain floating-point numbers. The floating-
point data-storage directives accept constant values. They do not
accept floating-point expressions.
The following example shows the use of expressions:
A = 2*100 ; 2*100 is an absolute expression
.BLKB A+50 ; A+50 is an absolute expression and
; contains no undefined symbols
LAB: .BLKW A ; LAB is relocatable
HALF = LAB+<A/2> ; LAB+<A/2> is a relocatable
; expression and contains no
; undefined symbols
LAB2: .BLKB LAB2-LAB ; LAB2-LAB is an absolute expression
; and contains no undefined symbols
10 – Unary Operators
A unary operator modifies a term or an expression and indicates
the action to be performed on that term or expression.
Expressions modified by unary operators must be enclosed in
angle brackets. You can use unary operators to indicate whether
a term or expression is positive or negative. If unary plus or
minus is not specified, the default value is plus. In addition,
unary operators perform radix conversion and numeric control
operations, as described in the following sections.
Table 3 Summary of Unary Operators
Unary Operator
OperatoName Example Operation
+ Plus +A Results in the positive value of A.
sign
- Minus -A Results in the negative (two's
sign complement) value of A.
\ Value of \symbol Indicates that the value of the symbol
Escape should be used. In a string literal,
indicates an escape sequence. For
example:
"Bob\X0A"
^A or ASCII ^A Specifies an ASCII constant.
^a /ABCD/
^B or Binary ^B1100011Specifies that 11000111 is a binary
^b number.
^D or Decimal ^D127 Specifies that 127 is a decimal
^d number.
^O or Octal ^O34 Specifies that 34 is an octal number.
^o
^X or Hexadecimal^XFCF9 Specifies that FCF9 is a hexadecimal
^x number.
^C or Complement ^C24 Produces the one's complement value of
^c 24 (decimal).
10.1 – Radix Control Operators
Radix control operators determine the radix of a term or
expression. MACRO-64 accepts terms or expressions in four
different radixes: binary, decimal, octal, and hexadecimal. The
default radix is decimal.
FORMATS
^Bnn
^Dnn
^Onn
^Xnn
nn
A string of characters that is legal in the specified radix. The
following are the legal characters for each radix:
Radix
Format Name Legal Characters
^Bnn Binary 0 and 1
^Dnn Decimal 0 to 9
^Onn Octal 0 to 7
^Xnn Hexadecimal0 to 9 and A to F
You can include radix control operators in the source program
anywhere a numeric value is legal. A radix control operator
affects only the term immediately following it, causing that
term to be evaluated in the specified radix. For example:
.WORD ^B00001101 ; Binary radix
.WORD ^D123 ; Decimal radix (default)
.WORD ^O47 ; Octal radix
Do not place spaces or tabs between the circumflex (^), the radix
specifier (B, D, O, or X), or the numeric value.
10.2 – Numeric Complement Operator
The complement operator (^C) produces the one's complement of
the specified value.
FORMAT
^Cterm
term
Any term or expression. If an expression is specified, it must be
enclosed in angle brackets.
MACRO-64 evaluates the term or expression as an 8-byte value
before complementing it. For example:
.LONG ^C^XFF ; Produces FFFFFF00 (hex)
.LONG ^C25 ; Produces complement of
; 25 (dec) which is
; FFFFFFE6 (hex)
11 – Binary Operators
In contrast to unary operators, binary operators specify
actions to be performed on two terms or expressions. You can
enclose expressions in angle brackets to specify the order of
evaluation.
Table 4 Summary of Binary Operators
BinaryOperator
OperatName ExampleOperation
+ Plus sign A+B Addition
- Minus sign A-B Subtraction
* Asterisk A*B Multiplication
/ Slash A/B Division
@ At sign A@B Arithmetic shift
& Ampersand A&B Logical AND (product)
! Exclamation A!B Logical OR (sum)
point
\ Backslash A\B Logical XOR (difference)
All binary operators have equal priority. You can group terms or
expressions for evaluation by enclosing them in angle brackets.
The enclosed terms and expressions are evaluated first, and
remaining operations are performed from left to right. For
example:
.LONG 1+2*3 ; Equals 9
.LONG 1+<2*3> ; Equals 7
Note that a 64-bit result is returned from all binary operations.
If you use the 64-bit result in a context requiring less than
64 bits, only the lower-order bits of the result are used. If
the truncation causes a loss of significance in a data-storage
directive, the assembler displays an error message.
The following sections describe the arithmetic shift, logical
AND, logical inclusive OR, and logical exclusive OR operators.
11.1 – Arithmetic Shift Operator
Use the arithmetic shift operator (@) to perform left and right
arithmetic shifts of arithmetic quantities. The first argument
is shifted left or right by the number of bit positions that
you specify in the second argument. If the second argument is
positive, the first argument is shifted left and the low-order
bits are set to zero. If the second argument is negative, the
first argument is shifted right and the high-order bits are set
to the value of the original high-order bit (the sign bit). For
example:
.LONG ^B101@4 ; Yields 1010000 (binary)
.LONG 1@2 ; Yields 100 (binary)
A = 4
.LONG 1@A ; Yields 10000 (binary)
.LONG ^X1234@-A ; Yields 123(hex)
11.2 – Logical AND Operator
The logical AND operator (&) takes the logical AND of two
operands. For example:
A = ^B1010
B = ^B1100
.LONG A&B ; Yields 1000 (binary)
11.3 – Logical Inclusive OR Operator
The logical inclusive OR operator (!) takes the logical
inclusive OR of two operands. For example:
A = ^B1010
B = ^B1100
.LONG A!B ; Yields 1110 (binary)
11.4 – Logical Exclusive OR Operator
The logical exclusive OR operator (\) takes the logical
exclusive OR of two arguments. For example:
A = ^B1010
B = ^B1100
.LONG A\B ; Yields 0110 (binary)
12 – Direct Assignment Statements
A direct assignment statement equates a symbol to a specific
value. Unlike a symbol that you use as a label, you can redefine
a symbol defined with a direct assignment statement as many times
as you want.
FORMATS
symbol=expression
symbol==expression
symbol=quoted-literal
symbol
A user-defined symbol.
expression
An expression that does not contain any undefined symbols or
forward references. The result must be either an absolute or
relocatable value, whose value can be determined at the current
point in the assembly. This form defines a numeric symbol.
The format with a single equal sign (=) defines a local symbol,
and the format with a double equal sign (==) defines a global
symbol.
The following three syntactic rules apply to direct assignment
statements:
o An equal sign (=) or double equal sign (==) must separate
the symbol from the expression that defines its value. Spaces
preceding or following the direct assignment operators have no
significance in the resulting value.
o Only one symbol can be defined in a single direct assignment
statement.
o A direct assignment statement can be followed only by a
comment field.
For best results, Digital recommends you place the symbol in a
direct assignment statement in the label field. For example:
A == 1 ; The symbol 'A' is globally
; equated to the value 1
B = A@5 ; The symbol 'B' is equated
; to 1@5 or 32(dec)
C = 127*10 ; The symbol 'C' is equated
; to 1270(dec)
D = ^X100/^X10 ; The symbol 'D' is equated
; to 10(hex)
quoted-literal
A literal within double quotes. This form defines a lexical
string symbol. You can only use lexical string symbols with
lexical string operators.
13 – Current Location Counter
The current location counter is a counter kept by an assembler to
determine the address assigned to an instruction or constant that
is being assembled. The symbol for the current location counter,
the period (.), represents the address of the current byte.
MACRO-64 sets the current location counter to 0 at the beginning
of the assembly and at the beginning of each new program section.
Every MACRO-64 source statement that allocates memory in the
object module increments the value of the current location
counter by the number of bytes allocated. For example, the
directive, .LONG 0 increments the current location counter by 4.
However, with the exception of the special form described later
in this section, a direct assignment statement does not increase
the current location counter because no memory is allocated.
The current location counter can be explicitly set by a special
form of the direct assignment statement. The location counter can
be either incremented or decremented. This method of setting the
location counter is often useful when defining data structures.
Data-storage areas should not be reserved by explicitly setting
the location counter; use the .BLKx directives.
FORMAT
.=expression
expression
An expression that does not contain any undefined or external
symbols.
In a relocatable psect, the expression must be relocatable; that
is, the expression must be relative to an address in the current
psect. It also may be relative to the current location counter.
For example:
. = .+40 ; Moves location counter forward
When a psect that you defined in the current module is continued,
the current location counter is set to the last value of the
current location counter in that psect.
In a psect with the EXE and NOMIX attributes:
o The location counter cannot be changed.
o If optimization is enabled, the location counter represents
the location before optimization.
In a psect with either the EXE or NOMIX (or both) attributes:
o The location counter can be changed.
o If you store an initial data or instruction value in memory
with a data directive such as .BYTE, .WORD, .LONG, or .QUAD
or with an instruction statement, you can replace that initial
value with a different initial value later in the assembly
by assigning the appropriate address value to the current
location counter and entering another data directive or
instruction statement. However, the new value must be the
same size and must start at exactly the same address as the
value it replaces.
14 – Lexical Operators
14.1 – Processing with Lexical Operators
Lexical operator processing is performed on all source lines
and macro expansion lines before any other assembler processing.
Thus, macro invocations, assembler directives, and instructions
are subject to lexical operator processing before normal
assembler processing.
Lexical operators are recognized and processed within string
literals. Lexical operator processing is suppressed during macro
registration in order that lexical operator evaluation may occur
during macro expansion. Lexical operator evaluation is also
suppressed for a range of text that is conditionally excluded
with one of the .IF directives. In addition, lexical operator
processing is not performed within a comment.
14.2 – Syntax
You invoke a lexical string operator with a percent sign followed
by the lexical operator name, a left parentheses, a list of
arguments separated by commas, and a right parentheses. The
following example shows the lexical operator syntax:
.print "%EDIT(<Fred>,<upcase>)"
Spaces are allowed between syntax elements in the general lexical
operator syntax. For example, the following syntax, including
spaces, is allowed:
.print "%EDIT ( <Fred> , <upcase> )"
Spaces are also allowed between the opening and closing percent
signs in a lexical substitution operator.
.print "% lexical_symbol_name %"
Spaces are not allowed between the pair of percent signs
indicating a lexical escape operator.
You can specify lexical operator arguments in the same way as
macro arguments:
o A numeric symbol name preceded by a backslash (\). This
construct results in the decimal value of the numeric symbol,
as shown in the following example:
\N
o Any string of characters surrounded by left- and right-angle
brackets, as shown in the following example:
<Foo bar thud>
You can nest angle brackets (<>). For example:
<<X+7>*17>
o Any string of characters surrounded by a delimiter specified
after a caret character (^). You cannot nest delimiters. For
example:
^%Foo bar thud%
o Any undelimited string of characters not separated by a space,
tab, form feed, comma, equal sign, semicolon, or end of line.
For example:
A+B+C
In addition to the formats allowed for a macro argument, you can
also specify lexical operator arguments as follows:
o An undelimited string of characters may also contain a string
of characters enclosed within left and right parentheses. The
characters between the left and right parentheses may contain
space, tab, or comma delimiters. For example:
16( R27 )
o You can use a lexical operator as an argument to another
lexical operator. For example:
%EXTRACT( %LOCATE($,X), %LENGTH(X) - %LOCATE($,X) ,X)
Except for the %TYPE lexical operator, a string symbol name
supplied as a lexical operator argument is replaced with the
value of the string symbol.
Each lexical operator accepts a given number of arguments and
each argument has a specific type. There are three different
types of arguments-string, integer, and name:
o A string argument can be any arbitrary sequence of characters.
o An integer argument must be an absolute or relocatable
expression that can be resolved at that point in the assembly.
A relocatable expression represents a psect and an offset
within that psect. If you specify a relocatable expression for
an integer argument, the assembler uses only the value of the
offset within the psect. The offset value is determined before
optimization and code alignment, but after data alignment.
o The name argument type is used only by the %TYPE lexical
operator. The %TYPE lexical operator accepts the name of a
numeric symbol, string symbol, label, psect, or a permanent
symbol as its argument. Unlike the other lexical operators, if
a string symbol name is specified as an argument to %TYPE, the
value of the string symbol is not substituted for its name.
Instead, information about the name is returned.
If you omit a string argument, the default is the empty string.
An empty string is a string with no characters. If you omit an
integer argument or specify an illegal expression, the default
value is 0. The assembler does not issue diagnostic messages
for illegal expressions used as arguments to lexical operators.
If you omit the name argument or specify an illegal name to the
%TYPE lexical operator, %TYPE returns a 0 value.
14.3 – Numeric Symbols and Lexical String Symbols
Lexical string symbols are similar in concept and syntax to
numeric symbols. MACRO-64 supports numeric symbols using the
following syntax:
numeric_symbol_name = numeric_expression
MACRO-64 supports lexical string symbols using the following
syntax:
string_symbol_name = "any string of characters"
The assembler differentiates between numeric symbol assignment
and lexical string symbol assignment as follows:
o In a lexical string symbol assignment, a quoted string literal
must appear after the equal sign.
o A lexical string symbol value is specified by the quoted
string literal.
The quotes are not included in the value of the lexical string
symbol. You cannot use the same name for a lexical string symbol,
numeric symbol, or label.
Like numeric symbols, lexical string symbols are assembly time
variables. After you assign a string value to a lexical string
symbol, you can reassign a different value to that symbol later
in the assembly.
You can use lexical string symbols as arguments to lexical
operators. In particular, you can use a lexical string symbol
as an argument to the lexical substitution operator (%) or the
%STRING lexical operator to substitute the value of the lexical
string symbol at any point in the text of your program.
14.4 – Lexical Substitution Operator
You can use the lexical substitution operator at any point in
your program to cause the assembler to substitute the value of
a lexical string symbol for the name of the symbol. The lexical
substitution operator is the percent sign (%). Place the lexical
substitution operator to the left and right of the name of the
lexical string symbol that you wish to subsitute, as follows:
%lexsym_name%
For example:
HORSES = "All the king's horses"
MEN = "all the king's men"
.print "%HORSES% and %MEN%"
This example defines two lexical string symbols: HORSES and MEN.
The third statement displays a message at assembly time. The text
of the message specifies that the value of the HORSES and MEN
lexical string symbols be substituted as indicated. After lexical
processing, the third statement appears as:
.print "All the king's horses and all the king's men"
14.5 – Lexical Escape Operator
It is possible to defer the processing of a lexical string
operator by using the lexical escape operator, which is the
percent sign (%). Since all lexical string operators begin with
a percent sign, the effect of placing two percent signs before
the name of the lexical string operator defers the evaluation of
the lexical string operator. If you want to defer processing of
a lexical substitution operator, place two percent signs to the
left and two percent signs to the right of the lexical string
symbol name.
This can be useful when you want the evaluation of a lexical
string operator that you have used in a default macro argument
to occur during macro expansion, rather than during macro
definition. Lexical operator processing is suppressed during
macro registration. Therefore, lexical operator processing is
automatically deferred within the body of a macro. However, the
.MACRO directive line that begins the macro definition is subject
to normal lexical operator processing. Sometimes you may need
to use the value of a lexical string symbol as the default for
a macro argument, but you need to use the value of the lexical
string symbol that is current when the macro expands, not when
the macro is defined. Lexical Processing Without the Escape
Operator shows an example of this, but it does not use an escape
operator.
Example 1 Lexical Processing Without the Escape Operator
CODE_PSECT_NAME = "CODE1"
.MACRO CODE_PSECT PSECT_NAME=%string(CODE_PSECT_NAME)
.PSECT PSECT_NAME
.ENDM CODE_PSECT
CODE_PSECT
CODE_PSECT_NAME = "CODE2"
CODE_PSECT
Lexical Processing Without the Escape Operator does not process
correctly for the following reasons:
o The lexical operator in the .MACRO directive line is processed
when the macro is defined, not when the macro expands.
o The CODE_PSECT macro always defaults to setting the psect
to the CODE1 psect because the default for the PSECT_NAME
argument will be set to CODE1, not %string(CODE_PSECT_NAME).
This is because %string(CODE_PSECT_NAME) is evaluated when the
CODE_PSECT macro is defined, not when it expands.
Lexical Processing with Escape Operator is similar to Lexical
Processing Without the Escape Operator except it uses the lexical
escape operator.
Example 2 Lexical Processing with Escape Operator
CODE_PSECT_NAME = "CODE1"
.macro CODE_PSECT PSECT_NAME=%%string(CODE_PSECT_NAME)
.psect PSECT_NAME
.endm CODE_PSECT
CODE_PSECT
CODE_PSECT_NAME = "CODE2"
CODE_PSECT
Lexical Processing with Escape Operator processes correctly for
the following reasons:
o Lexical operator processing of %%string(CODE_PSECT_NAME)
is deferred when the CODE_PSECT macro is defined. The
default value for the PSECT_NAME argument is stored as
%string(CODE_PSECT_NAME).
o During macro expansion, %string(CODE_PSECT_NAME) is evaluated,
which results in the current value of the CODE_PSECT_NAME
lexical string symbol as desired.
14.6 – %EDIT
Lexical operator for editing text strings.
Format
%EDIT (string1,string2)
14.6.1 – Arguments
string1
The first argument, of type string, specifies the string to be
edited.
string2
The second argument, of type string, specifies a list of edits to
perform, which are separated by commas.
14.6.2 – Description
%EDIT is modeled after the OpenVMS DCL lexical function F$EDIT.
It is used to perform one or more edits on a specified string.
%EDIT processes the string of arguments from left to right. %EDIT
gives precedence to the last argument. %EDIT gives precedence to
uppercase over lowercase.
The list of edits may contain any combination of the following
elements:
Element Function
COLLAPSE Removes all tabs and spaces.
COMPRESS Replaces multiple, consecutive tabs or spaces with a
single space.
LOWERCASE Changes uppercase characters to lowercase.
TRIM Removes leading and trailing spaces and tabs.
UPCASE Changes lowercase characters to uppercase.
14.6.3 – Examples
Example 1
.PRINT "%EDIT(< Fred Smith >, <TRIM,COLLAPSE,UPCASE>)"
After lexical processing, the statement apears as the
following:
.PRINT "FREDSMITH"
Example 2
.PRINT "%EDIT(<AbCdEfG>,<upcase,lowercase>)
.PRINT "%EDIT(<AbCdEfG>,<lowercase,upcase>)
The first source statement produces the string "abcdefg" and
the second source statement produces the string "ABCDEFG". Each
of the edits in the edit list is performed in sequence, from
left to right.
14.7 – %ELEMENT
Lexical operator for extracting elements from a list of elements.
Format
%ELEMENT (integer,string1,string2)
14.7.1 – Arguments
integer
The first argument, of type integer, is the element number to
extract. The first element is number 0.
string1
The second argument, of type string, is the delimiter or
delimiters that separate elements.
string2
The third argument, of type string, is the list of elements.
14.7.2 – Description
%ELEMENT is modeled after the OpenVMS DCL lexical function
F$ELEMENT. It is used to extract one element from a string of
elements. Note that unlike F$ELEMENT, you may specify multiple
delimiters. The result is the specified string element. If the
specified element number is greater than the number of elements
in the list, the delimiter argument is returned.
14.7.3 – Example
.PRINT "%ELEMENT (2, <+-*/>, JOE+FRED-TOM*BILL/ERIC)"
After lexical processing, the statement appears as:
.PRINT "TOM"
14.8 – %EXTRACT
Lexical operator for extracting a range of characters from a
string of characters.
Format
%EXTRACT (integer1,integer2,string)
14.8.1 – Arguments
integer1
The first argument, of type integer, is the offset at which to
begin the extraction. The first character is at offset 0.
integer2
The second argument, of type integer, is the number of characters
to extract.
string
The third argument, of type string, is the string from which to
extract the characters.
14.8.2 – Description
%EXTRACT is modeled after VAX MACRO's %EXTRACT macro string
operator and the OpenVMS DCL lexical function F$EXTRACT. %EXTRACT
is used to extract a specified range of characters from a string.
14.8.3 – Example
.PRINT "%EXTRACT(3,4,ABCDEFGHIJKLMNOP)"
After lexical processing, the statement appears as:
.PRINT "DEFG"
14.9 – %FREG
Lexical operator for obtaining the floating-point register number
associated with a symbol.
Format
%FREG (symbol)
14.9.1 – Argument
symbol
The single argument, of type string, specifies a symbol that
may or may not be currently defined as a floating-point register
symbol.
14.9.2 – Description
%FREG returns the decimal number of the floating-point register
when the specified symbol is defined as a floating-point register
symbol. Otherwise, %FREG returns 32.
14.9.3 – Example
; Is TARG_REG the same as F31?
.IF EQ, <%FREG(TARG_REG)>, <%FREG(31)>
If TARG_REG has been defined as floating-point register F5, the
statements appear as follows after lexical processing:
; Is TARG_REG the same as F31?
.IF EQ, <5>, <31>
14.10 – %INTEGER
Lexical operator for converting the value of an expression to a
decimal value.
Format
%INTEGER (integer)
14.10.1 – Argument
integer
The single argument, of type integer, is the expression to be
converted.
14.10.2 – Description
%INTEGER is modeled after the OpenVMS DCL lexical function
F$INTEGER. It is used to convert the value of an expression to
a decimal value. The result is its decimal value. You can also
use %INTEGER to convert a relocatable expression to an absolute
value.
14.10.3 – Example
.PRINT "%INTEGER (<<X+7>*17>)"
After lexical processing, if X has the value 3, the statement
will appear as:
.PRINT "170"
14.11 – %IREG
Lexical operator for obtaining the integer register number
associated with a symbol.
Format
%IREG (symbol)
14.11.1 – Argument
symbol
The single argument, of type string, specifies a symbol that may
or may not be currently defined as an integer register symbol.
14.11.2 – Description
%IREG returns the decimal number of the integer register when
the specified symbol is defined as an integer register symbol.
Otherwise, %IREG returns 32.
14.11.3 – Example
; Is SRC_REG the same as SP?
.IF EQ, <%IREG(SRC_REG)>, <%IREG(SP)>
If SRC_REG has been defined as integer register R16, the
statements appear as follows after lexical processing:
; Is SRC_REG the same as SP?
.IF EQ, <16>, <30>
14.12 – %LENGTH
Lexical operator for determining the length of a string.
Format
%LENGTH (string)
14.12.1 – Argument
string
The single argument, of type string, is the string from which the
length is to be computed.
14.12.2 – Description
%LENGTH is modeled after VAX MACRO's %LENGTH macro string
operator and the OpenVMS DCL lexical function F$LENGTH. %LENGTH
is used to determine the length of a string. The result is the
length of the string expressed as a decimal number.
14.12.3 – Example
.PRINT "%LENGTH(<The quick brown fox>)"
After lexical processing, the statement appears as:
.PRINT "19"
14.13 – %LOCATE
Lexical operator for locating a string of text within another
string of text.
Format
%LOCATE (string1,string2)
14.13.1 – Arguments
string1
The first argument, of type string, is the string for which
%LOCATE searches.
string2
The second argument, of type string, is the string in which the
search is performed.
14.13.2 – Description
%LOCATE is modeled after VAX MACRO's %LOCATE macro string
operator and the OpenVMS DCL lexical function F$LOCATE. %LOCATE
is used to locate one string within another. The value returned
is the decimal offset to the first occurrence of the first string
within the second string. The offset to the first character is 0.
If the first string cannot be found within the second string, the
length of the second string is returned.
14.13.3 – Example
.PRINT "%LOCATE (DEF,ABCDEFGHIJKLMNOP)"
After lexical processing, the statement appears as:
.PRINT "3"
14.14 – %REPEAT
Lexical operator for repeating a specified string a specified
number of times.
Format
%REPEAT (integer,string)
14.14.1 – Arguments
integer
The first argument, of type integer, is the number of times to
repeat the string. If you specify a negative value, the string is
repeated 0 times.
string
The second argument, of type string, is the string to be
repeated.
14.14.2 – Description
%REPEAT is used to repeat the specified string a specified number
of times.
14.14.3 – Example
.PRINT "Never, %REPEAT (3, <ever, >)touch that button!"
After lexical processing, the statement appears as:
.PRINT "Never, ever, ever, ever, touch that button!"
14.15 – %STRING
Lexical operator for obtaining the value of a lexical string
symbol.
Format
%STRING (string)
14.15.1 – Argument
string
The single argument is of type string. If the argument is the
name of the lexical string symbol, the value of the lexical
string symbol is returned. Otherwise, the argument is returned
unchanged.
14.15.2 – Description
%STRING is modeled after the OpenVMS DCL lexical function
F$STRING. %STRING is generally used to obtain the value of
a lexical string symbol, but you can use it with any string
argument.
14.15.3 – Example
FOO = "All the king's horses"
.PRINT "%STRING(FOO)"
After lexical processing, the statement appears as:
.PRINT "All the king's horses"
14.16 – %TIME
Lexical operator for obtaining the date and time of the assembly
unit.
Format
%TIME ()
14.16.1 – Description
%TIME is modeled after the OpenVMS DCL lexical function F$TIME.
%TIME is used to obtain the time and date of the assembly unit.
There are no arguments. The result is a string specifying the
date and time of the assembly unit.
14.16.2 – Example
.PRINT "%TIME()"
After lexical processing, the statement appears as:
.PRINT " 8-OCT-1991 13:17:57"
14.17 – %TYPE
Lexical operator for obtaining information about a name.
Format
%TYPE (name)
14.17.1 – Argument
name
The single argument is of type name. Information is returned
about the name specified in the argument.
14.17.2 – Description
%TYPE is modeled after the OpenVMS DCL lexical function
F$TYPE. %TYPE is used to obtain information about a name. The
value returned is a numeric value with certain bit positions,
either 0 or 1, depending on whether the specified name has the
corresponding attribute. As described elsewhere, the decimal
digits of the numeric value are substituted for the %TYPE lexical
operator. %TYPE Attributes shows the symbolic names that are
predefined for each attribute.
Table 5 %TYPE Attributes
Symbolic Name Attribute
MACRO64$TYPE_SYMBOL Name is a numeric symbol name.
MACRO64$TYPE_PROC_ Name is a procedure descriptor name.
DESC
MACRO64$TYPE_LABEL Name is a label.
MACRO64$TYPE_EXTERN Name is an external name.
MACRO64$TYPE_WEAK Name is a weak name.
MACRO64$TYPE_PSECT Name is a psect.
MACRO64$TYPE_MACRO Name is a macro name.
MACRO64$TYPE_STRING Name is a lexical string symbol name.
MACRO64$TYPE_OPCODE Name is an opcode.
MACRO64$TYPE_DIR Name is a directive.
MACRO64$TYPE_GENREG Name is a general register.
MACRO64$TYPE_FLTREG Name is a floating register.
A given name may have zero, one, or several attributes.
14.17.3 – Example
.macro IS_GR ARG
.IF equal, %TYPE(ARG) & <MACRO64$TYPE_GENREG>
.PRINT "ARG is not a general register"
.ENDC
.endm IS_GR
IS_GR F11
Initially, the first line of the IS_GR macro expands as the
following:
.IF equal, <%TYPE(F11) & MACRO64$TYPE_GENREG>
After lexical processing, the statement appears as:
.IF equal, <8192 & MACRO64$TYPE_GENREG>
In this example, 8192 is the attribute value for a floating-
point register. This value could change in subsequent releases.
Use only the predefined attribute masks described in %TYPE
Attributes. Since the attribute for a general register
MACRO64$TYPE_GENREG is 4096, the expression evaluates as 0.
<8192 & MACRO64$TYPE_GENREG>
15 – Macros
By using macros, you can use a single source statement to insert
a sequence of source statements into a program.
A macro definition contains the source statements of the macro.
The macro definition may have formal arguments. You can use these
formal arguments throughout the sequence of source statements
within the definition. When the macro is called, the formal
arguments are replaced by the actual arguments within the macro
call.
The macro call is a single source statement consisting of the
macro name, optionally followed by arguments. When the macro
is called, the assembler replaces the line containing the macro
call with the source statements in the macro definition. The
assembler replaces any occurrences of formal arguments in the
macro definition with the actual arguments specified in the macro
call. This process is called the macro expansion.
By default, macro expansions are not printed in the assembly
listing. To print the macro expansions, you must specify the
/SHOW=EXPANSIONS qualifier and argument in the command line. Note
that the examples of macro expansions used in this chapter are
listed as they would appear using the /SHOW=EXPANSIONS qualifier
and argument.
Use .SHOW with a symbolic argument of EXPANSIONS in the source
text of a program to specify the listing of expansions.
15.1 – Arguments
Macros have two types of arguments: actual and formal. Actual
arguments are the text given in the macro call after the name
of the macro. Formal arguments are specified by name in the
macro definition; that is, after the macro name in the .MACRO
directive. Actual arguments in macro calls and formal arguments
in macro definitions can be separated by commas (,), tabs, or
spaces.
The number of actual arguments in the macro call can be less
than or equal to the number of formal arguments in the macro
definition. If the number of actual arguments is greater than
the number of formal arguments, the assembler displays an error
message.
Formal and actual arguments normally maintain a strict positional
relationship. That is, the first actual argument in a macro call
replaces all occurrences of the first formal argument in the
macro definition. This strict positional relationship can be
overridden by using keyword arguments. See the section on keyword
arguments.
An example of a macro definition using formal arguments follows:
.MACRO STORE ARG1,ARG2,ARG3
.LONG ARG1 ; ARG1 is first argument
.WORD ARG3 ; ARG3 is third argument
.BYTE ARG2 ; ARG2 is second argument
.ENDM STORE
The following two examples show possible calls and expansions of
the macro previously defined:
STORE 3,2,1 ; Macro call
.LONG 3 ; 3 is first argument
.WORD 1 ; 1 is third argument
.BYTE 2 ; 2 is second argument
STORE X,X-Y,Z ; Macro call
.LONG X ; X is first argument
.WORD Z ; Z is third argument
.BYTE X-Y ; X-Y is second argument
15.2 – Default Values
Default values are values that are defined in the macro
definition. They are used when no value for a formal argument
is specified in the macro call.
Default values are specified in the .MACRO directive as follows:
formal-argument-name = default-value
An example of a macro definition specifying default values
follows:
.MACRO STORE ARG1=12,ARG2=0,ARG3=1000
.LONG ARG1
.WORD ARG3
.BYTE ARG2
.ENDM STORE
The following three examples show possible calls and expansions
of the macro defined previously:
STORE ; No arguments supplied
.LONG 12
.WORD 1000
.BYTE 0
STORE ,5,X ; Last two arguments supplied
.LONG 12
.WORD X
.BYTE 5
STORE 1 ; First argument supplied
.LONG 1
.WORD 1000
.BYTE 0
15.3 – Keyword Arguments
Keyword arguments allow a macro call to specify the arguments
in any order. In this case, the macro call must specify the
same formal argument names that appear in the macro definition.
Keyword arguments are useful when a macro definition has more
formal arguments than necessary in the call.
In any one macro call, it is good practice to specify the
arguments as either all positional arguments or all keyword
arguments. For example, the following macro definition specifies
three arguments:
.MACRO STORE ARG1,ARG2,ARG3
.LONG ARG1
.WORD ARG3
.BYTE ARG2
.ENDM STORE
The following macro call specifies keyword arguments:
STORE ARG3=27+5/4,ARG2=5,ARG1=SYMBL
.LONG SYMBL
.WORD 27+5/4
.BYTE 5
Because the keywords are specified in the macro call, the
arguments in the macro call need not be given in the order they
were listed in the macro definition.
Positional and keyword arguments may be mixed. Usually,
positional arguments are placed before keyword arguments. For
example:
.MACRO STORE ARG1,ARG2,ARG3=27+5/4
.LONG ARG1
.BYTE ARG2
.WORD 27+5/4
.ENDM STORE
NOTE
Keyword arguments are not counted when positional arguments
are parsed. This means that when positional and keyword
arguments are used in the same macro, one argument can be
specified twice. The last value specified for the argument
is used.
15.4 – String Arguments
If an actual argument is a string containing characters that
the assembler interprets as separators (such as a tab, space,
or comma), the string must be enclosed by delimiters. String
delimiters for macro arguments are usually paired angle brackets
(<>). A quoted literal enclosed in double quotes ("") is also a
valid string argument.
The assembler also interprets any character
(except A, B, C, D, O, or X) after an initial circumflex (^)
as a delimiter. Note that ^B, ^D, ^O, and ^X are used as radix
control operators rather than argument delimiters. ^A is used
as the ASCII operator and ^C is used as the complement operator.
To pass an angle bracket as part of a string, you can use the
circumflex form of the delimiter.
The following are examples of delimited macro arguments:
<HAVE THE SUPPLIES RUN OUT?>
<LAB: CLR R4>
"A quoted literal is taken as a single parameter value."
^%ARGUMENT IS <LAST,FIRST> FOR CALL%
^?EXPRESSION IS <5+3>*<4+2>?
In the last two examples, the initial circumflex indicates
that the percent sign (%) and question mark (?) are the
delimiters. Note that only the left-hand delimiter is preceded
by a circumflex.
The assembler interprets a string argument enclosed by delimiters
as one actual argument and associates it with one formal
argument. If a string argument that contains separator characters
is not enclosed by delimiters, the assembler interprets it as
successive actual arguments and associates it with successive
formal arguments.
For example, the following macro definition has one formal
argument:
.MACRO DOUBLE_ASCII STRNG
.ASCII "STRNG"
.ASCII "STRNG"
.ENDM DOUBLE_ASCII
The following two macro calls demonstrate actual arguments with
and without delimiters:
DOUBLE_ASCII <A B C D E>
.ASCII "A B C D E"
.ASCII "A B C D E"
DOUBLE_ASCII A B C D E
%MACRO64-E-TOOMNYARGS, Too many arguments in macro call
Note that the assembler interprets the second macro call as
having five actual arguments instead of one actual argument with
spaces.
When a macro is called, the assembler removes normal delimiters
around a string before associating it with the formal arguments.
However, a quoted literal within double quotes is treated as a
single token and retains its double quote delimiters.
If a string contains a semicolon (;), the string must be
enclosed by delimiters; otherwise, the semicolon will mark the
start of the comment field. Further, if the string contains a
semicolon, you cannot continue the line unless the string is a
quoted literal.
You can nest macro invocations, that is, a macro definition can
contain a call to another macro. If, within a macro definition,
another macro is called and is passed a string argument, you must
delimit the argument so that the entire string is passed to the
second macro as one argument.
The following macro definition contains a call to the DOUBLE_
ASCII macro defined earlier:
.MACRO CNTDA LAB1,LAB2,STR_ARG
LAB1: .BYTE LAB2-LAB1-1 ; Length of 2*string
DOUBLE_ASCII <STR_ARG>
; Call DOUBLE_ASCII macro
LAB2:
.ENDM CNTDA
Note that the argument in the call to DOUBLE_ASCII is enclosed in
angle brackets even though it does not contain any separator
characters. The argument is thus delimited because it is a
formal argument in the definition of the macro CNTDA and will
be replaced with an actual argument that may contain separator
characters.
The following example calls the macro CNTDA, which in turn calls
the macro DOUBLE_ASCII:
CNTDA ST,FIN,<LEARN YOUR ABC'S>
ST: .BYTE FIN-ST-1
DOUBLE_ASCII <LEARN YOUR ABC'S>
.ASCII "LEARN YOUR ABC'S"
.ASCII "LEARN YOUR ABC'S"
FIN:
In addition to nested macro invocations, you can
also nest macro definitions. That is, you can define
one macro within another. In this example, the
INNER_MACRO_DEF macro is not defined until the OUTER_MACRO_DEF
macro is invoked and expanded:
.macro OUTER_MACRO_DEF
.macro INNER_MACRO_DEF
...
.endm INNER_MACRO_DEF
.endm OUTER_MACRO_DEF
You can use this capability to define a macro that redefines
itself:
.macro SETUP
A = 75
B = 92
C = 87
D = 0
E = -12
F = 42
.macro SETUP
; Setup is done - do nothing
.endm SETUP
.endm SETUP
In this example, the SETUP macro defines a number of assembly
constants. After the SETUP macro has been expanded once, its
work is done. Subsequent expansions of the setup macro need not
take any action. Therefore, the SETUP macro redefines itself
to a macro whose expansion includes only a comment statement.
As described elsewhere, when you redefine a macro, the original
version of the macro is automatically deleted. If that macro is
currently expanding (as would be the case with the previous SETUP
macro), the new definition is immediately associated with the
macro name. However, the old definition is retained until all
pending expansions complete normally. When all pending expansions
complete, the old version of the macro is deleted. Thus, the
SETUP macro may be invoked any number of times in the assembly
unit. Since the first expansion redefines itself, the expansion
of the SETUP macro has no effect other than the first time it is
invoked.
Another way to pass string arguments in nested macros is to
enclose the macro argument in nested delimiters.
NOTE
Each time you use the delimited argument in a macro call,
the assembler removes the outermost pair of delimiters
before associating it with the formal argument. This method
is not recommended because it requires that you know how
deeply a macro is nested.
The following macro definition also contains a call to the
DOUBLE_ASCII macro:
.MACRO CNTDA2 LAB1,LAB2,STR_ARG
LAB1: .BYTE LAB2-LAB1-1 ; Length of 2*string
DOUBLE_ASCII STR_ARG ; Call DOUBLE_ASCII macro
LAB2:
.ENDM CNTDA2
Note that the argument in the call to DOUBLE_ASCII is not
enclosed in angle brackets.
The following example calls the macro CNTDA2:
CNTDA2 BEG,TERM,<<MIND YOUR P'S AND Q'S>>
BEG: .BYTE TERM-BEG-1 ; Length of 2*string
DOUBLE_ASCII <MIND YOUR P'S AND Q'S>
; Call DOUBLE_ASCII macro
.ASCII "MIND YOUR P'S AND Q'S"
.ASCII "MIND YOUR P'S AND Q'S"
TERM:
Note that even though the call to DOUBLE_ASCII in the macro
definition is not enclosed in delimiters, the call in the
expansion is enclosed because the call to CNTDA2 contains nested
delimiters around the string argument.
15.5 – Argument Concatentation
The argument concatenation operator, the apostrophe ('),
concatenates a macro argument with constant text or another
argument. Apostrophes can either precede or follow a formal
argument name in the macro source.
If an apostrophe precedes the argument name, the text before
the apostrophe is concatenated with the actual argument when
the macro is expanded. For example, if ARG1 is a formal argument
associated with the actual argument TEST, then ABCDE'ARG1 is
expanded to ABCDETEST.
If an apostrophe follows the formal argument name, the actual
argument is concatenated with the text that follows the
apostrophe when the macro is expanded. The apostrophe itself
does not appear in the macro expansion.
To concatenate two arguments, separate the two formal arguments
with two successive apostrophes. Two apostrophes are needed
because each concatenation operation discards an apostrophe from
the expansion.
An example of a macro definition that uses concatenation follows:
.MACRO CONCAT A,B
A''B: .WORD 0
.ENDM CONCAT
Note that two successive apostrophes are used when concatenating
the two formal arguments A and B.
An example of a macro call and expansion follows:
CONCAT X,Y
XY: .WORD 0
15.6 – Passing Numeric Values of Symbols
When a symbol is specified as an actual argument, the name of
the symbol, not the numeric value of the symbol, is passed to
the macro. You can pass the value of the symbol by inserting a
backslash (\) before the symbol in the macro call. The assembler
passes the characters representing the decimal value of the
symbol to the macro. For example, if the symbol COUNT has a value
of 2 and the actual argument specified is \COUNT, the assembler
passes the string 2 to the macro; it does not pass the name of
the symbol, COUNT.
Passing numeric values of symbols is especially useful with the
apostrophe (') concatenation operator for creating new symbols.
An example of a macro definition for passing numeric values of
symbols follows:
.MACRO WORD n
WORD'n: .WORD n
.ENDM WORD
The following example shows a possible call and expansion of the
macro previously defined:
X = 1 ; Start counting at 1
WORD \X
WORD1: .WORD 1
15.7 – Created Temporary Labels
Temporary labels are often very useful in macros. You can create
a macro definition that specifies temporary labels within it,
but these temporary labels might be duplicated elsewhere in the
temporary label block, possibly causing errors. However, the
assembler can create temporary labels in the macro expansion that
will not conflict with other temporary labels. These labels are
called created temporary labels.
Created temporary labels range from 30000$ to 65535$. Each time
the assembler creates a new temporary label, it increments the
numeric part of the label name by 1. Consequently, no user-
defined temporary labels should be in the range of 30000$ to
65535$.
A created temporary label is specified by a question mark (?) in
front of the formal argument name. When the macro is expanded,
the assembler creates a new temporary label if the corresponding
actual argument is blank. If the corresponding actual argument is
specified, the assembler substitutes the actual argument for the
formal argument.
The following example is a macro definition specifying a created
temporary label:
.MACRO POSITIVE ARG1,?L1
BGE ARG1,L1
NEGQ ARG1,ARG1
L1: .ENDM POSITIVE
The following three calls and expansions of the macro defined
previously show both created temporary labels and a user-defined
temporary label:
POSITIVE R0
BGE R0,30000$
NEGQ R0,R0
30000$:
POSITIVE R5
BGE R5,30001$
NEGQ R5,R5
30001$:
POSITIVE R7,10$
BGE R7,10$
NEGQ R7,R7
10$:
16 – Program Sections
MACRO-64 allows you to divide your program into sections called
psects using the .PSECT directive. Psects are useful for
organizing your program, and for low-level control over the
linking process. More importantly, each psect falls into one
of the following three categories:
o CODE psects can contain only instructions. They contain no
data. Psects in this category have the EXE and NOMIX psect
attributes.
o DATA psects can contain only data. They contain no
instructions. Psects in this category have the NOEXE and NOMIX
attributes.
o MIXED psects can contain instructions, data, or both. Psects
in this category have the MIX attribute. In addition, they may
have either the EXE or NOEXE attribute.
MACRO-64 categorizes psects because:
o There is a significant performance compromise associated
with mixing instructions and data in the same program section
within the Alpha architecture. This is because the Alpha
architecture typically maintains separate memory caches
for instructions and data.
o If you mix instructions and data, it is likely that
instructions will migrate into the data cache and that
data will migrate into the instruction cache. While this
situation still yields correct results, the benefits of the
instruction and data caches are diminished. Placing data in
the instruction stream can also have detrimental effects on
the instruction pipeline and the multiple instruction-issue
capabilities that most Alpha systems employ.
Since a code psect can contain only instructions and cannot
contain arbitrary data, instructions you place in a CODE psect
can be analyzed by the assembler optimizer and by the symbolic
debugger. Since a mixed psect can contain arbitrary data as well
as instructions, instructions you place in a mixed psect are not
analyzed by the assembler optimizer or by the symbolic debugger.
Instead, the assembler internally converts instructions in a
mixed psect to an equivalent data representation.
Because of the compromises associated with mixed psects, by
default the assembler creates psects with the NOMIX psect
attribute. If you need to place data in a psect that has the
EXE attribute, or if you need to place instructions in a psect
that has the NOEXE attribute, you must also specify the MIX
attribute in the psect's definition. Note that unlike the other
psect attributes, the MIX psect attribute is an assembly-time
attribute. The MIX psect attribute does not appear in the psect
definitions in your object module and it does not affect the
linking process.
You can use all assembler directives and instructions within
mixed psects. While many assembler directives can be used
within both code and data psects, data-storage directives
cannot be used in code psects and instructions and instruction-
storage directives cannot be used in data psects. If you place
instructions or instruction-storage directives in a data psect,
or if you place data-storage directives in a code psect, the
assembler issues a diagnostic message.
In summary, code psects may contain only storage for instructions
and storage created by instruction directives. Data psects may
contain only storage created by data directives. Mixed psects may
contain either storage for instructions or data or both. There
are no restrictions on the use of data directives in a mixed
psect. However, the assembler converts instructions you place in
a mixed psect to a data representation. Therefore, instructions
in a mixed psect are not analyzed as instructions by either the
assembler optimizer or the symbolic debugger.
17 – Automatic Data Alignment
The assembler can optionally align your data on natural
boundaries. While disabled by default, this feature is
enabled with the /ALIGNMENT=DATA command-line qualifier or the
.ENABLE ALIGN_DATA directive. A natural boundary is an address
that is evenly divisibly by the size of the scalar data type
being accessed. The MACRO-64 automatic data alignment feature can
automatically align word, longword, quadword, and octaword data
to a natural boundary. Accessing data on a natural boundary can
be significantly faster than an unaligned access.
When the MACRO-64 automatic data alignment feature is enabled,
the assembler automatically aligns all data-storage directives to
a natural boundary. To achieve alignment, the assembler pads
with 0 bytes as necessary before allocating the storage for
the data directive. Labels that occur before the data-storage
directive are defined to be the address of the data storage after
alignment.
18 – Directives
The general assembler directives provide facilities for
performing eleven types of functions. Some directives are only
applicable within data psects (psects with the NOEXE and NOMIX
attributes). Other directives are only applicable within code
psects (psects with the EXE and NOMIX attributes). All directives
are applicable within psects that contain either data and code,
or both (psects with the MIX attribute). For information on the
MIX assembly-time psect and any associated restrictions, see the
description of the .PSECT directive in this chapter.
The following table discusses these types of functions and their
directives.
18.1 – .ADDRESS
Address storage directive
Format
.ADDRESS address-list
18.1.1 – Parameter
address-list
A list of symbols or expressions, separated by commas (,), which
MACRO-64 interprets as addresses.
18.1.2 – Description
.ADDRESS stores successive quadwords (8 bytes) containing
addresses in the object module. Digital recommends that you use
.ADDRESS rather than .QUAD for storing address data to provide
additional information to the linker.
18.1.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current (64-bit) boundary before allocating storage.
o You can define a 32-bit address item using macros and the
.LONG directive. For example:
.macro address_32 item
.long item
.endm address_32
18.1.4 – Example
.ADDRESS A,B,C
18.2 – .ALIGN
Location counter alignment directive
Format
.ALIGN integer [,fill-specifier]
.ALIGN keyword [,fill-specifier]
18.2.1 – Parameters
integer
An integer in the range 0 to 9. The location counter is aligned
at an address that is the value of 2 raised to the power of the
integer.
keyword
One of five keywords that specify the alignment boundary. The
location counter is aligned to an address that is the next
multiple of the following values:
Keyword Size (in Bytes)
BYTE 20= 1
WORD 21= 2
LONG 22= 4
QUAD 23= 8
OCTA 24= 16
[,fill-specifier]
Any expression that resolves to an assembly-time integer value
containing no forward references. The filling is done per byte,
regardless of the alignment. If the value you specify is not in
the range of 0 to 255, the assembler issues a diagnostic message
and truncates the value.
18.2.2 – Description
.ALIGN aligns the location counter to the boundary specified by
either an integer or a keyword.
18.2.3 – Notes
o If .ALIGN is specified in a psect with the EXE and NOMIX
attributes, the fill-specifier is ignored. The assembler
aligns the psect to the requested boundary padding with NOP
or FNOP instructions.
o If .ALIGN is specified in a psect that does not have the EXE
attribute and a fill-specifier is specified, the assembler
aligns the psect to the requested boundary padding, with byte
locations using the fill-specifier as the initial value for
the generated byte padding.
o If the fill-specifier expression encounters a value that is
too large to fit in a boundary specified by the keyword, the
data is truncated and an informational message is displayed.
o The alignment that you specify in .ALIGN cannot exceed the
alignment of the psect in which the alignment is attempted
(see the description of .PSECT). For example, if you are using
the BYTE psect alignment and you specify .ALIGN with a word or
larger alignment, the assembler displays an error message.
18.2.4 – Examples
Example 1
.PSECT A,QUAD ; Begin at quadword
B::.BYTE 4 ; Data is byte
.ALIGN QUAD ; Next data is
C::.WORD 6 ; also quadword aligned
Example 2
.PSECT A,EXE,NOMIX,OCTA
L1::TRAPB: ; offset 0
.ALIGN OCTA ; NOP padding bytes 4..15
TRAPB: ; offset 16
Example 3
.PSECT A,NOEXE,NOMIX,OCTA
L1:.WORD 5 ; byte offset 0..1
.ALIGN QUAD,2 ; fill specifier initial value
; of 2 for bytes 2..7
.WORD 6 ; byte offsets 8..9
18.3 – .ASCIC
Counted ASCII string storage directive
Format
.ASCIC quoted-literal
18.3.1 – Parameter
quoted-literal
An ASCII string delimited with double quotes.
18.3.2 – Description
.ASCIC performs the same function as .ASCII, except that .ASCIC
inserts a count byte before the string data. The count byte
contains the length of the string in bytes. The length given
includes any bytes of nonprintable characters specified using the
backslash (\) operator, but excludes the count byte.
.ASCIC is useful in copying text because the count indicates the
length of the text to be copied.
18.3.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o This directive also accepts VAX MACRO syntax.
18.3.4 – Example
.ASCIC "MY STRING" ; In the listing, this becomes:
; .BYTE 9
; .ASCII \MY STRING\
18.4 – .ASCID
String-descriptor ASCII string storage directive
Format
.ASCID quoted-literal
18.4.1 – Parameter
quoted-literal
An ASCII string delimited with double quotes.
18.4.2 – Description
.ASCID performs the same function as the .ASCII directive, except
that .ASCID inserts a string descriptor before the string data.
The descriptor format is identical to that defined for OpenVMS
Alpha and OpenVMS VAX. The string descriptor has the following
format:
18.4.3 – Notes
o String descriptors are used in calling certain system
routines.
o The string-length field is two bytes in size.
o Descriptor information (2 bytes) is always set to ^X010E.
o The pointer field is a 32-bit pointer to the string (4 bytes).
o If natural alignment is enabled (using .ENABLE ALIGN_DATA),
the descriptor is quadword aligned. This allows you to access
the entire descriptor (2 data words and a longword address) on
a quadword boundary.
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o This directive also accepts VAX MACRO syntax. See the
VAX MACRO and Instruction Set Reference Manual for details.
18.4.4 – Examples
Example 1
.DESCR1: .ASCID "ARGUMENT FOR CALL" ; String descriptor
Example 2
.DESCR2: .ASCID "SECOND ARGUMENT" ; Another string descriptor
18.5 – .ASCII
ASCII string storage directive
Format
.ASCII quoted-literal
18.5.1 – Parameters
quoted-literal
An ASCII string delimited with double quotes.
18.5.2 – Description
.ASCII stores the ASCII value of each character in the ASCII
string or the value of each byte expression in the next available
byte.
18.5.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o This directive also accepts VAX MACRO syntax. See the
VAX MACRO and Instruction Set Reference Manual for details.
18.5.4 – Examples
.ASCII "MY STRING"
18.6 – .ASCIZ
Zero-terminated ASCII string storage directive
Format
.ASCIZ quoted-literal
18.6.1 – Parameter
quoted-literal
An ASCII string delimited with double quotes.
18.6.2 – Description
.ASCIZ performs the same function as .ASCII, except that .ASCIZ
appends a null byte as the final character of the string. When a
list or text string is created with an .ASCIZ directive, you need
only perform a search for the null character in the last byte to
determine the end of the string.
18.6.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o This directive also accepts VAX MACRO syntax. See the
VAX MACRO and Instruction Set Reference Manual for details.
18.6.4 – Example
.ASCIZ "MY STRING" ; Equivalent to
; .ASCII "MY STRING \x00"
18.7 – .BASE
Base register directive
Format
.BASE Rn [,base_expression]
18.7.1 – Parameters
Rn
One of the base registers, R0 through R30, FP, and SP.
base_expression
The base address, which is optional, and can be one of the
following:
o An absolute expression
o A relocatable expression
o An external expression
An expression must not contain forward references or implicit
external symbols. An implicitly defined external symbol is a
symbol that the assembler defaults to an external symbol. This
occurs when the assembler encounters references to a symbol, but
does not encounter a definition for the symbol or an .EXTERNAL
directive that declares the symbol.
18.7.2 – Description
The .BASE directive is used to inform the assembler that a
specified base register contains a specified base address. Later
in your program, the assembler allows you to implicitly reference
the specified base register. When the assembler knows which
base addresses are stored in one or more base registers, it can
convert an expression to an offset from one of the base registers
previously specified in a .BASE directive. .BASE provides a
convenient and more readable shorthand for accessing memory and
constant values using base registers. .BASE also makes it easier
for you to change your register assignments if you later modify
your code.
The base expression is optional. If the base expression is
specified, this base address value is assumed by the assembler
to be in the specified register, Rn. If the base expression is
omitted, the contents of the specified base register, Rn, is
considered undefined until a new base expression is associated
with the base register.
R31 is defined to always contain 0, according to the architecture
definition. Therefore, R31 is known to be a predefined base
register containing 0. For every assembly, the assembler assumes
the following statement:
.BASE R31, 0
Because the contents of R31 cannot change, you cannot specify a
base address for R31.
You can use the .BASE directive to implicitly reference base
registers. You can also automatically compute offsets from a base
address known to be in a register to a base address you use in an
instruction argument.
Most of the memory format Alpha instructions are defined
such that one of their arguments must have a base register and
an offset. If the assembler encounters only an expression with
no base register, the assembler attempts to find a base register
that contains a base address or constant within a 16-bit signed
offset of the value of the expression. If it finds such a base
register, the assembler computes an offset that, when added to
the value of the base register, results in a value equal to the
expression specified in the instruction argument.
18.7.3 – Examples
Example 1
.EXTERNAL COMM_AREA 1
.BASE R1, COMM_AREA 2
CURR_LINE = COMM_AREA + 0
CURR_COLUMN = COMM_AREA + 4
CURR_MODE = COMM_AREA + 8
LDA R4, 17 ; LDA R4, 17(R31) 3
LDL R2, CURR_LINE ; LDL R2, 0(R1) 4
LDL R3, CURR_COLUMN ; LDL R3, 4(R1)
STL R4, CURR_MODE ; STL R4, 8(R1)
1 This statement declares an external symbol, COMM_AREA.
COMM_AREA is a global symbol that represents the base
address of a three-longword communication area that is used
by different routines in the program.
2 This statement informs the assembler that base register R1
contains the base address, COMM_AREA, of this communication
area. The next three statements define variables within the
communication area.
3 The first instruction shows how you can load registers
with constant values in the range -32,768 to +32,767 by
implicitly using R31 as the base register.
4 The last three statements show how the .BASE directive
allows you to implicitly reference base registers
and automatically compute offsets. In each of these
instructions, the second argument is defined to require
an offset and a base register.
Since no base register is specified, the assembler attempts
to imply the base register and compute the offset based upon
information given in previous .BASE directives.
In the last three instructions, the address argument is
within -32,768 to +32,767 of the base address known to
be in R1 (that is, COMM_AREA). Therefore, R1 is selected
as the base register. The assembler also computes the
correct offset from the base address known to be in R1 to
the address specified in the instruction argument.
Example 2
The assembler performs a sequential search through the list
of possible base registers, R0 through R31. It uses the first
definition possible if multiple base registers are valid. For
example:
.BASE R5, 300
:
LDQ R10, 100
The assembler outputs the LDQ instruction as follows:
LDQ R10, -200(R5)
Both R31 and R5 are defined as base registers that can be used
in constructing the instruction argument. R31 always contains
0. In this example, R5 is also known to contain the constant
300. The assembler uses the first base register, starting at
R0 and progressing to R31, which provides a known value within
-32,768 to +32,767 of the specified argument value. Since the
assembler considers R5 before it considers R31, R5 is used
rather than R31.
18.8 – .BEGIN EXACT
Exact instruction block directive
Format
.BEGIN_EXACT
18.8.1 – Description
An exact instruction block suppresses code optimizations
(SCHEDULE and PEEPHOLE) regardless if these optimizations are
enabled for the assembly unit. Unlike .ENABLE and .DISABLE, which
can be used to enable or disable specific optimizations for the
entire assembly unit, .BEGIN_EXACT and .END_EXACT allow you to
suppress optimization for a specified range of instructions.
Instructions outside the specified range remain subject to any
optimizations you have enabled.
18.8.2 – Notes
o This directive cannot appear in a psect with the NOEXE and
NOMIX attributes.
o Although this directive is accepted by the assembler in a
psect with the MIX attribute, it has no effect in these psects
since no code optimizations are in affect for MIX psects.
o .BEGIN_EXACT must be paired with a matching .END_EXACT to
close the exact instruction block.
o .BEGIN_EXACT and .END_EXACT instruction blocks can be
nested. The outermost level of the .BEGIN_EXACT and matching
.END_EXACT directives delimit the actual exact instruction
block from which code optimizations are suppressed. Nesting
.BEGIN_EXACT and .END_EXACT instruction blocks can be useful
in macro definitions where the macro expansion requires an
exact instruction sequence. Nested .BEGIN_EXACT and .END_EXACT
instruction blocks allow a macro to be invoked both from
within and without the exact instruction block.
o .BEGIN_EXACT does not affect automatic alignment. Automatic
alignment is enabled with the .ENABLE ALIGN_CODE and .ENABLE
ALIGN_DATA directives or with the /ALIGN=(CODE,DATA) command-
line qualifier.
18.8.3 – Examples
The following example shows an instruction sequence prior to
optimization:
addf f7, f8, f9 ; 1
addf f2, f3, f4 ; 2
addl r5, r6, r7 ; 3
addl r8, r9, r10 ; 4
The assembler optimizes the previous example to a sequence
similar to the following instruction sequence:
:
addf f7, f8, f9 ; 1
addl r5, r6, r7 ; 3
addf f2, f3, f4 ; 2
addl r8, r9, r10 ; 4
:
If you choose to suppress optimization in the previous example,
enclose the four instructions with the .BEGIN_EXACT and
.END_EXACT directives, as shown in the following example:
.BEGIN_EXACT
addf f7, f8, f9 ; 1
addf f2, f3, f4 ; 2
addl r5, r6, r7 ; 3
addl r8, r9, r10 ; 4
.END_EXACT
18.9 – .BLKx
Block storage allocation directives
Format
.BLKA [expression]
.BLKB [expression]
.BLKD [expression]
.BLKF [expression]
.BLKG [expression]
.BLKL [expression]
.BLKO [expression]
.BLKQ [expression]
.BLKS [expression]
.BLKT [expression]
.BLKW [expression]
18.9.1 – Parameter
expression
An integer expression specifying the amount of storage to be
allocated. All the symbols in the expression must be defined
at the current point in the assembly and the expression must be
an absolute expression. If the expression is omitted, a default
value of 1 is assumed.
18.9.2 – Description
MACRO-64 has the following 11 block storage directives:
DirectivReserves Storage for: Bytes Allocated
.BLKA Addresses (quadwords) 8 * value of expression
.BLKB Byte data Value of expression
.BLKD Double-precision 8 * value of expression
floating-point data
(quadwords)
.BLKF Single-precision 4 * value of expression
floating-point data
(longwords)
.BLKG G_floating data 8 * value of expression
(quadwords)
.BLKL Longword data 4 * value of expression
.BLKO Octaword data 16 * value of expression
.BLKQ Quadword data 8 * value of expression
.BLKS S_floating data 4 * value of expression
(longwords)
.BLKT T_floating data 8 * value of expression
(quadwords)
.BLKW Word data 2 * value of expression
Each directive reserves storage for a different data type. The
value of the expression determines the number of data items for
which MACRO-64 reserves storage. For example, .BLKL 4 reserves
storage for 4 longwords of data and .BLKB 2 reserves storage for
2 bytes of data. The total number of bytes reserved is equal to
the length of the data type times the value of the expression.
18.9.3 – Notes
o If automatic data alignment is enabled, the .BLKx directives
align the current location counter to one of the alignments
listed in the following table:
DirectiAlignment
.BLKA Quadword (64-bit) boundary
.BLKB None
.BLKD Quadword (64-bit) boundary
.BLKF Longword (32-bit) boundary
.BLKG Quadword (64-bit) boundary
.BLKL Longword (32-bit) boundary
.BLKO Octaword (128-bit) boundary
.BLKQ Quadword (64-bit) boundary
.BLKS Longword (32-bit) boundary
.BLKT Quadword (64-bit) boundary
.BLKW Word (16-bit) boundary
o You can only use these directives within psects having either
the NOEXE or MIX attributes.
18.9.4 – Example
.PSECT A,NOEXE
B:: .BLKW 10 ; 10 words (20 bytes) of storage
.BLKQ 5 ; 5 quadwords (40 bytes) of storage
.BLKW ; 1 word (2 bytes) of storage
18.10 – .BYTE
Byte storage directive
Format
.BYTE expression-list
18.10.1 – Parameter
expression-list
One or more expressions separated by commas. Each expression
is first evaluated as a quadword expression; then the value of
the expression is truncated to fit in a byte. The value of each
expression should be in the range 0 to 255 for unsigned data or
in the range -128 to +127 for signed data.
18.10.2 – Description
.BYTE generates successive bytes of binary data in the object
module.
18.10.3 – Notes
o The assembler displays a warning message if the expression is
outside the range -128 to -255.
o The assembler will truncate the most significant bits of an
integer or external value that is too large to store in eight
bits.
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
18.10.4 – Example
A: .BYTE 5 ; Stores 5 in a byte
18.11 – .CODE ADDRESS
Code address storage directive
Format
.CODE_ADDRESS name-list
18.11.1 – Parameter
name-list
A list of symbols separated by commas. These symbols should
reference either a procedure descriptor name, such as a routine
name, or an externally defined procedure descriptor.
18.11.2 – Description
.CODE_ADDRESS causes the code addresses of the specified
identifiers to be placed at the current psect and current
location counter. The specified identifier should reference a
procedure descriptor defined in the image.
18.11.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a quadword (64-bit) boundary
before allocating storage.
18.11.4 – Example
.CODE_ADDRESS A
18.12 – .D FLOATING
Floating-point storage directive
Format
.D_FLOATING floating-point-number-list
.DOUBLE floating-point-number-list
18.12.1 – Parameter
floating-point-number-list
A comma-separated list of floating-point constants. The constants
cannot contain any operators except unary plus or unary minus.
18.12.2 – Description
.D_FLOATING evaluates the specified floating-point constants and
stores the results in the object module. .D_FLOATING generates
64-bit, double-precision floating-point data (1 bit of sign, 8
bits of exponent, and 55 bits of fraction). See the description
of .F_FLOATING for information on storing single-precision
floating-point numbers and the descriptions of .G_FLOATING, .S_
FLOATING, and .T_FLOATING for descriptions of other floating-
point constants.
18.12.3 – Notes
o Double-precision floating-point numbers are always rounded.
o The alternate form of .D_FLOATING is .DOUBLE.
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a quadword (64-bit) boundary
before allocating storage.
o The Alpha architecture supports only conversion operations
for the
D floating-point data type.
18.12.4 – Example
.D_FLOATING 3.1E+02
18.13 – .DEFINE FREG
Define floating-point register symbol directive
Format
.DEFINE_FREG regsym regnum
18.13.1 – Parameters
regsym
A MACRO-64 identifier.
regnum
An assembly-time expression or a currently defined register
symbol.
18.13.2 – Description
The identifier you specify as the first argument to .DEFINE_FREG
becomes a floating-point register symbol. Thereafter, it cannot
be used as a MACRO-64 identifier. Specifically, the user-defined
register symbol is only allowed where a register is allowed. In
this sense, the user-defined register symbol is reserved until
the end of the assembly unit or until you delete its definition
(see .UNDEFINE_REG), whichever occurs first.
The second argument to .DEFINE_FREG can be either an integer
expression or a currently defined floating-point register symbol.
An integer expression indicates the register number to assign
to the register symbol. The expression can contain no forward
or external references and must be in the range of 0 to 31.
Alternatively, you can define a register symbol in terms of
another currently defined register symbol. A currently defined
register symbol is a predefined register symbol or a register
symbol that you have previously defined. In this case, the new
register symbol you specify with the first argument receives the
current value of the register symbol you specify with the second
argument.
18.13.3 – Notes
o You cannot define a floating-point register in terms of an
integer register and vice versa.
o You cannot redefine a currently defined register symbol with a
different register number. To redefine a register symbol, you
must first delete the old definition with the .UNDEFINE_REG
directive.
18.13.4 – Example
.DEFINE_IREG A0 16 ; A0 is integer register 16
.DEFINE_IREG A1 R17 ; A1 is integer register 17,
; defined in terms of the
; predefined R17 register symbol
.DEFINE_IREG PTR A0 ; PTR is integer register 16,
; defined in terms of the
; previously-defined A0 register
; symbol
.DEFINE_FREG $F0 0 ; $F0 is floating register 0
.DEFINE_FREG $F1 F1 ; $F1 is floating register 1,
; defined in terms of the
; predefined F1 register symbol
.DEFINE_FREG RADIUS $F1 ; RADIUS is floating register 1,
; defined in terms of the
; previously defined $F1
; register symbol
.DEFINE_IREG X1 R5 ; X1 is integer register 5,
; defined in terms of the
; predefined R5 register symbol
.DEFINE_IREG X1 5 ; 2nd definition is the same
; value, so no diagnostic
; results
.DEFINE_IREG X1 7 ; Warning: redefinition with a
; different value
.DEFINE_IREG X2 F5 ; Error: cannot define an integer
; register in terms of a
; floating register
LDQ R1, (PTR) ; LDQ R1, (R16)
LDG RADIUS, (A1) ; LDG F1, (R17)
18.14 – .DEFINE IREG
Define integer register symbol directive
Format
.DEFINE_IREG regsym regnum
18.14.1 – Parameters
regsym
A MACRO-64 identifier.
regnum
An assembly-time expression or a currently defined register
symbol.
18.14.2 – Description
The identifier you specify as the first argument to .DEFINE_IREG
becomes an integer register symbol. Thereafter, it cannot be
used as a MACRO-64 identifier. Specifically, the user-defined
register symbol is only allowed where a register is allowed. In
this sense, the user-defined register symbol is reserved until
the end of the assembly unit or until you delete its definition
(see .UNDEFINE_REG), whichever occurs first.
The second argument to .DEFINE_IREG can be either an integer
expression or a currently defined integer register symbol.
An integer expression indicates the register number to assign
to the register symbol. The expression can contain no forward
or external references and must be in the range of 0 to 31.
Alternatively, you can define a register symbol in terms of
another, currently defined register symbol. A currently defined
register symbol is a predefined register symbol or a register
symbol that you have previously defined. In this case, the new
register symbol you specify with the first argument receives the
current value of the register symbol you specify with the second
argument.
18.14.3 – Notes
o You cannot define an integer register in terms of a floating-
point register and vice versa.
o You cannot redefine a currently defined register symbol with a
different register number. To redefine a register symbol, you
must first delete the old definition with the .UNDEFINE_REG
directive.
18.14.4 – Example
Refer to the example in .DEFINE_FREG.
18.15 – .DISABLE
Disable assembler functions directive
Format
.DISABLE argument-list
.DSABL argument-list
18.15.1 – Parameter
argument-list
One or more of the symbolic arguments listed in the description
of .ENABLE. You can use either the long or the short form of the
symbolic arguments. If you specify multiple arguments, separate
them by commas, spaces, or tabs.
18.15.2 – Description
.DISABLE disables the specified assembler function. See the
description of .ENABLE for more information.
The alternate form of .DISABLE is .DSABL.
18.16 – .ELSE
Conditional assembly block directive
Format
.ELSE
18.16.1 – Description
A conditional assembly block is a series of source statements
that is assembled only if a certain condition is met. .IF starts
the conditional block and .ENDC ends the conditional block; each
.IF must have a corresponding .ENDC. The .IF directive contains
a condition test and one or two arguments. The condition test
specified is applied to the arguments. If the test is met, all
MACRO-64 statements between .IF and .ELSE are assembled. If
the test is not met, the statements between .ELSE and .ENDC are
assembled.
Conditional blocks can be nested; that is, a conditional block
can be inside another conditional block. In this case, the
statements in the inner conditional block are assembled only
if the condition is met for both the outer and inner block. For
more information, see the description of the .IF directive.
18.16.2 – Notes
o You cannot use the .ELSE directive in the same conditional
block as the .IF_x directive.
o The .ELSE directive is similar to the .IF_FALSE directive.
However, you can only use .ELSE once within a conditional
block. .IF_FALSE can be used any number of times in a
conditional block.
18.16.3 – Example
Here is an example of a conditional assembly directive:
.IF EQUAL ALPHA+1 ; Assemble block if ALPHA+1=0.
.
.
.ELSE ; Assemble when .IF=false.
.
.
.ENDC
18.17 – .ENABLE
Enable assembler functions directive
Format
.ENABLE argument-list
.ENABL argument-list
18.17.1 – Parameter
argument-list
One or more of the symbolic arguments You can use either the long
form or the short form of the symbolic arguments.
If you specify multiple arguments, separate them with commas,
spaces, or tabs.
Table 6 .ENABLE and .DISABLE Symbolic Arguments
Short Default
Long Form Form Condition Function
ALIGN_CODE Disabled The code alignment option aligns
certain branch target labels. The
ALIGN_CODE option is disabled for
the assembly unit if any one of the
following is true:
o /NOALIGNMENT=CODE is specified on
the command line.
o .DISABLE ALIGN_CODE is specified in
the source program.
o The /ALIGNMENT=CODE option is
defaulted.
ALIGN_DATA Disabled When ALIGN_DATA is disabled, the data-
storage directives put each succeeding
item on the next byte boundary.
When ALIGN_DATA is enabled, the data-
storage directives put each succeeding
item on natural boundaries (such as
words on word boundaries, longwords on
longword boundaries) and add pad bytes
as necessary.
Accessing data on anything other than
natural boundaries usually incurs a
significant performance penalty.
You can enable or disable the
ALIGN_DATA option for specific ranges
within your program.
FLOAT Enabled Controls whether the assembler
generates floating-point instructions
when optimizing code and performing
code-label alignment.
Currently, the only floating-point
instruction generated by the assembler
during optimization and alignment
processing is FNOP, the floating-
point no-operation instruction. If you
specify .DISABLE FLOAT, the assembler
does not generate any floating-point
instructions as part of optimization
and alignment processing.
The initial value of this option is
specified by the /ENVIRONMENT=[NO]FLOAT
command-line option. The last value of
the FLOAT option at the end of assembly
determines whether FLOAT is enabled or
DISABLED.
GLOBAL GBL Enabled When GLOBAL is enabled, the assembler
implicitly treats any undefined symbol
as an external reference defined in
another module. If the GLOBAL option
is disabled, the assembler issues
a warning and implicitly treats
the undefined symbol as an external
reference assumed to be defined in
another module. The last value of the
GLOBAL option at the end of assembly
determines whether the GLOBAL option is
enabled or disabled.
LOCAL_BLOCK LSB Disabled Used to override the default assembler
behavior to define a temporary label
block. (A temporary label is of the
form n$ where n represents a number.)
A temporary label block is usually
delimited by two user-defined local
or global labels. However, the .ENABLE
LOCAL_BLOCK directive defines the start
of a block that is terminated by one of
the following:
o A second .ENABLE LOCAL_BLOCK
directive.
o A .DISABLE LOCAL_BLOCK directive
followed by a user-defined local or
global label, or a .PSECT directive.
PEEPHOLE Disabled Peephole optimization reduces the
strength of certain instructions and
eliminates instructions where possible.
The PEEPHOLE option is disabled for
the assembly unit if any one of the
following is true:
o /NOOPTIMIZE=PEEPHOLE is specified on
the command line.
o .DISABLE PEEPHOLE is specified in
the source program.
o The PEEPHOLE option is defaulted.
PREPROCESSOR_ Enabled When PREPROCESSOR_OUTPUT is enabled,
OUTPUT the MACRO-64 preprocessor processes
your source statements and outputs to
the preprocessor-output file. If the
PREPROCESSOR_OUTPUT option is disabled,
your source statements are processed
as before. However, output of these
statements to the preprocessor-output
file is suppressed.
Neither .ENABLE PREPROCESSOR_OUTPUT
nor .DISABLE PREPROCESSOR_OUTPUT is
passed through to the preprocessor-
output file. These two directives
have no effect unless you specify
/PREPROCESSOR_ONLY on the command line.
SCHEDULE Disabled Instruction scheduling optimization
reorders instructions to more optimally
utilize the instruction pipeline.
The SCHEDULE option is disabled for
the assembly unit if any one of the
following is true:
o /NOOPTIMIZE=SCHEDULE is specified on
the command line.
o .DISABLE SCHEDULE is specified in
the source program.
o The SCHEDULE option is defaulted.
18.17.2 – Description
.ENABLE enables the specified assembly function. .ENABLE and
its negative form, .DISABLE, control the following assembler
functions:
o Creating local label blocks
o Specifying that undefined symbol references are external
references
o Enabling or disabling specific optimizations for the assembly
unit
You can enable one or more specific optimization options with
either the .ENABLE directive or the /OPTIMIZE command-line
qualifier, or both. If you explicitly disable one or more
specific optimization options with the .DISABLE directive, those
optimization options are disabled regardless of the command-line
options you specify.
18.17.3 – Notes
o The alternate form of .ENABLE is .ENABL.
18.17.4 – Examples
Example 1
The following example shows the ALIGN_DATA option:
.PSECT A, NOEXE
.ENABLE ALIGN_DATA ; Align on natural
; natural boundaries
A: .BYTE 1 ;
B: .QUAD 1000 ; B is allocated at
; a natural boundary -
; specifically at A + 7
.DISABLE ALIGN_DATA ;
C: .BYTE 2 ;
D: .QUAD 1001 ; D is allocated at
; an unaligned boundary -
; specifically C + 1
Example 2
The following example shows the GLOBAL option disabled:
.DISABLE GLOBAL
.ADDRESS X ; Assembler issues a warning
.END
Example 3
The following example shows the LOCAL_BLOCK option enabled:
.ENABLE LOCAL_BLOCK
.PSECT A,NOEXE
A1::
5$: .PROCEDURE_DESCRIPTOR PROC_1 ; Temporary label 5$
.blkb 32
A2::
.address 5$ ; By default the declaration
; of A2 would have ended the
; temporary label block and
; made this reference to 5$
; illegal. However, this default
; behavior has been overridden
; by the use of .ENABLE LOCAL_BLOCK.
.DISABLE LOCAL_BLOCK
.END
Example 4
The following example shows an unoptimized and optimized list
of instructions with the SCHEDULE and PEEPHOLE options enabled:
.ENABLE PEEPHOLE,SCHEDULE
.psect A,EXE,QUAD ; unoptimized
TRAPB
A::ADDF F1,F2,F3
ADDF F4,F5,F6
ADDL R1,R2,R3
ADDL R4,R5,R6
This example shows the optimized list of instructions:
.ENABLE PEEPHOLE,SCHEDULE
.psect A,EXE,QUAD ; optimized
A::ADDF F1,F2,F3
ADDL R1,R2,R3
ADDF F4,F5,F6
ADDL R4,R5,R6
The following example shows a repeat block that initializes
a block of 1000 longwords to the values of 0 through 999. The
.DISABLE PREPROCESSOR_OUTPUT directive suppresses from the
preprocessor output file those statements that are incompatible
with the OSF/1 Assembler.
.DISABLE PREPROCESSOR_OUTPUT
I=0
.REPEAT 1000
.ENABLE PREPROCESSOR_OUTPUT
.LONG %INTEGER(I)
.DISABLE PREPROCESSOR_OUTPUT
I = I + 1
.ENDR
18.18 – .END
Assembly termination directive
Format
.END [label]
18.18.1 – Parameter
label
The procedure descriptor name that specifies the routine (called
the transfer address) where program execution begins. This
argument is optional.
18.18.2 – Description
.END terminates the source program. No additional text should
occur beyond this point in the current source file, or in any
additional source files specified in the command line for this
assembly. If any additional text does occur, the assembler
ignores it. The additional text does not appear in the listing
file nor does it affect the object file.
18.18.3 – Notes
o When an executable image consisting of several object modules
is linked, only one object module should be terminated by an
.END directive that specifies a transfer address. All other
object modules should be terminated by .END directives that
do not specify a transfer address. If an executable image
contains either no transfer address or more than one transfer
address, the linker displays an error message.
o For more information, see the .PROCEDURE_DESCRIPTOR directive.
18.18.4 – Example
.
.
.
.PROCEDURE_DESCRIPTOR TRANSFER1,code_address_T1
.
.
.
.END TRANSFER1 ; TRANSFER1 is module transfer address
18.19 – .ENDC
End conditional directive
Format
.ENDC
18.19.1 – Description
.ENDC terminates the conditional range started by the .IF
directive. See the description of .IF for more information and
examples.
18.20 – .ENDM
End macro definition directive
Format
.ENDM [macro-name]
18.20.1 – Parameter
macro-name
The name of the macro whose definition is to be terminated. The
macro name is optional; if specified, it must match the name
defined in the matching .MACRO directive. The macro name should
be specified so that the assembler can detect any improperly
nested macro definitions.
18.20.2 – Description
.ENDM terminates the macro definition. See the description of
.MACRO for an example that uses an .ENDM directive.
18.20.3 – Notes
o If .ENDM is encountered outside a macro definition, the
assembler displays an error message.
18.21 – .ENDR
End repeat range directive
Format
.ENDR
18.21.1 – Description
.ENDR indicates the end of a repeat range. It must be the final
statement of every repeat block. A repeat block consists of
any range of text beginning with the .IRP, .IRPC, or .REPEAT
directive. For more information, see the description for the
.IRP, .IRPC, or .REPEAT directives for examples of how to use the
.ENDR directive.
18.21.2 – Notes
o If .ENDR is encountered outside a repeat block, the assembler
displays an error message.
18.22 – .END EXACT
End exact instruction block directive
Format
.END_EXACT
18.22.1 – Description
.END_EXACT delimits the end of an exact instruction block. An
exact instruction block suppresses the SCHEDULE and PEEPHOLE
optimizations for the specified range of instructions regardless
if code optimizations are enabled for the assembly unit.
For more information on the .END_EXACT directive, see the
description of the .BEGIN_EXACT directive in this chapter.
18.23 – .ERROR
Error directive
Format
.ERROR quoted-literal
18.23.1 – Parameter
quoted-literal
A string of characters, between a pair of double quotes,
displayed during assembly.
18.23.2 – Description
.ERROR causes the assembler to display an error message on the
terminal or batch log file and in the listing file (if there is
one).
Using .ERROR prevents an output object file from being produced.
18.23.3 – Notes
o .PRINT, .WARN, and .ERROR are directives used to display
messages. You can use them to display information indicating
unexpected or important conditions within the assembly.
o This directive also accepts VAX MACRO syntax. See the
VAX MACRO and Instruction Set Reference Manual for details.
18.23.4 – Example
.ERROR "Illegal Arguments"
^
%MACRO64-E-GENERROR, Generated ERROR: Illegal Arguments
at line number 3 in file DISK$:[TEST]ERROR.M64;2
18.24 – .EVEN
Even location counter alignment directive
Format
.EVEN
18.24.1 – Description
.EVEN ensures that the current value of the location counter
is even by adding 1 if the current value is odd. If the current
value is already even, no action is taken.
18.24.2 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
18.25 – .EXTERNAL
External symbol attribute directive
Format
.EXTERNAL symbol-list
.EXTRN symbol-list
18.25.1 – Parameter
symbol-list
A list of symbol names separated by commas.
18.25.2 – Description
.EXTERNAL indicates that the specified symbols are external; that
is, the symbols are defined in another object module.
18.25.3 – Notes
o The alternate form of .EXTERNAL is .EXTRN.
18.25.4 – Example
.EXTERNAL B ; B is defined in another module
.
.
.
A:: .ADDRESS B ; Its address is stored here
18.26 – .F FLOATING
Floating-point storage directive
Format
.F_FLOATING floating-point-number-list
.FLOAT floating-point-number-list
18.26.1 – Parameter
floating-point-number-list
A list of one or more floating-point constants separated by
commas. The constants cannot contain any operators except unary
plus or unary minus.
18.26.2 – Description
.F_FLOATING evaluates the specified floating-point constant(s)
and stores the results in the object module. .F_FLOATING
generates 32-bit, single-precision, floating-point data (1
bit of sign, 8 bits of exponent, and 23 bits of fractional
significance). See the description of .D_FLOATING for information
on storing double-precision floating-point constants and the
descriptions of .G_FLOATING, S_FLOATING, and T_FLOATING for
descriptions of other floating-point constants.
18.26.3 – Notes
o The alternate form of .F_FLOATING is .FLOAT.
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a longword (32-bit) boundary
before allocating storage.
18.26.4 – Example
.F_FLOATING 1.0,3.0E+2
18.27 – .G FLOATING
G_floating-point storage directive
Format
.G_FLOATING floating-point-number-list
18.27.1 – Parameter
floating-point-number-list
A comma-separated list of one or more floating-point constants.
The constants cannot contain any operators except unary plus or
unary minus.
18.27.2 – Description
.G_FLOATING evaluates the specified floating-point constants and
stores the results in the object module. .G_FLOATING generates
64-bit data (1 bit of sign, 11 bits of exponent, and 52 bits of
fraction). See the description of .D_FLOATING for information
on storing double-precision floating-point constants and the
descriptions of .F_FLOATING, S_FLOATING, and T_FLOATING for
descriptions of other floating-point constants.
18.27.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a quadword (64-bit) boundary
before allocating storage.
18.27.4 – Example
.G_FLOATING 2.0E-3
18.28 – .IDENT
Identification directive
Format
.IDENT quoted-literal
18.28.1 – Parameter
quoted-literal
A 1- to 31-character string, within double quotes, that
identifies the module, such as a string that specifies a version
number.
18.28.2 – Description
.IDENT provides a means of identifying the object module. This
identification is in addition to the name assigned to the object
module with .TITLE. You can specify a character string in .IDENT
to label the object module. This string is printed in the header
of the listing file and also appears in the object module.
18.28.3 – Notes
o If a source module contains more than one .IDENT, the last
directive given establishes the character string that forms
part of the object module identification.
o This directive also accepts VAX MACRO syntax. See the
VAX MACRO and Instruction Set Reference Manual for details.
18.28.4 – Example
.IDENT "Module Name"
18.29 – .IF
Conditional assembly block directive
Format
.IF condition argument(s)
.
.
.
range
.
.
.
.ENDC
18.29.1 – Parameters
condition
A specified condition that must be met if the block is to be
included in the assembly. The condition must be separated from
the argument by a comma, space, or tab.
argument(s)
One or more symbolic arguments or expressions of the specified
conditional test. If the argument is an expression, it cannot
contain any undefined symbols. The assembler converts relocatable
arguments to absolute arguments by discarding the relocatable
portion of the expression and using only the offset from the
beginning of the psect. Arguments must be separated by a comma.
range
The block of source code that is conditionally included in the
assembly.
Table 7 Condition Tests for Conditional Assembly Directives
Condition
Condition Complement Number That
Test Condition Argument of Assembles
Test Type Arguments Block
Long Short Short
Form Form Long Form Form
EQUAL EQ NOT_EQUAL NE Expression 1 or 2 Expression-
1 is
equal to
expression-
2 or not
equal to
expression-
2.
GREATER GT LESS_EQUAL LE Expression 1 or 2 Expression-
1 is
greater
than
expression-
2 or
less
than or
equal to
expression-
2.
LESS_ LT GREATER_ GE Expression 1 or 2 Expression-
THAN EQUAL 1 is
less
than
expression-
2 or
greater
than or
equal to
expression-
2.
DEFINED DF NOT_DEFINED NDF Symbolic 1 Symbol
is
defined
or not
defined.
BLANK B NOT_BLANK NB Macro 1 Argument
is blank
or not
blank.
IDENTICAL IDN DIFFERENT DIF Macro 2 Arguments
are
identi-
cal or
differ-
ent.
18.29.2 – Description
A conditional assembly block is a series of source statements
that are assembled only if a certain condition is met. A .IF
starts the conditional block and a .ENDC ends the conditional
block; each .IF must have a corresponding .ENDC. The .IF
directive contains a condition test and one or two arguments.
The condition test specified is applied to the arguments. If
the test is met, all MACRO-64 statements between .IF and .ENDC
are assembled. If the test is not met, the statements are not
assembled. Optionally, you can use the .ELSE directive (or a
combination of the .IFF, .IFT, and .IFTF directives) to specify
an alternate series of statements to assemble if the test is not
met.
You can nest conditional blocks; that is, a conditional block
can be inside another conditional block. In this case, the
statements in the inner conditional block are assembled only
if the condition is met for both the outer and inner block.
18.29.3 – Notes
o The assembler displays an error message if the following
directives occur outside a conditional assembly block: .ENDC,
.ELSE, .IF_FALSE, .IF_TRUE, .IF_TRUE_FALSE.
o MACRO-64 permits a nesting depth of 100 conditional assembly
levels. If a statement attempts to exceed this nesting level
depth, the assembler displays an error message.
o The effect of logical expressions can only be achieved by
using several levels of .IF directives. See Example 5.
o Lowercase string arguments are converted to uppercase before
being compared, unless the string is surrounded by double
quotes or /NAMES=AS_IS is specified on the command line.
o The assembler displays an error message if .IF specifies any
of the following: a condition test other than those which are
valid, an illegal argument, or a null argument specified in an
.IF directive.
18.29.4 – Examples
Example 1
Here is an example of a conditional assembly directive:
.IF EQUAL ALPHA+1 ; Assemble block if ALPHA+1=0. Do
. ; not assemble if ALPHA+1 not=0
.
.
.ENDC
Example 2
Nested conditional directives take the following form:
.IF condition argument(s)
.IF condition argument(s)
.
.
.
.ENDC
.ENDC
Example 3
The following conditional directives can govern whether
assembly of the specified range is to occur:
.IF DEFINED SYM1
.IF DEFINED SYM2
.
.
.
.ENDC
.ENDC
In this example, if the outermost condition is not satisfied,
no deeper level of evaluation of nested conditional statements
within the program occurs. Therefore, both SYM1 and SYM2 must
be defined for the specified range to be assembled.
Example 4
An alternate series of statements can be specified using .ELSE.
.IF EQUAL A,B ; Assemble if A is equal to B
.ELSE ; Assemble if A is not equal to B
.ENDC
Example 5
The following example demonstrates the use of .ELSE and
nesting:
.IF LESS_THAN X,Y ; Assemble if X is less than Y
.IF DEFINED Z ; Assemble if Z is defined and
; X is less than Y
.ELSE ; Assemble if Z is not defined and
; X is less than Y
.ENDC
.ELSE ; Assemble if X is greater than or equal to Y
.IF DEFINED Z ; Assemble if Z is defined and X is
; greater than or equal to Y
.ENDC
.ENDC
18.30 – .IF x
Subconditional assembly block directives
Format
.IF_FALSE
.IF_TRUE
.IF_TRUE_FALSE
18.30.1 – Description
For compatibility with VAX MACRO, MACRO-64 provides three
directives for use within .IF blocks:
Directive Function
.IF_FALSE If the condition of the assembly block tests false,
the program includes the source code following
the .IF_FALSE directive and continuing up to the
next subconditional directive or to the end of the
conditional assembly block.
.IF_TRUE If the condition of the assembly block tests true,
the program includes the source code following
the .IF_TRUE directive and continuing up to the
next subconditional directive or to the end of the
conditional assembly block.
.IF_TRUE_ Regardless of whether the condition of the
FALSE assembly block tests true or false, the source
code following the .IF TRUE_FALSE directive (and
continuing up to the next subconditional directive
or to the end of the assembly block) is always
included.
The implied argument of a subconditional directive is the
condition test specified when the conditional assembly block was
entered. A conditional or subconditional directive in a nested
conditional assembly block is not evaluated if the preceding (or
outer) condition in the block is not satisfied (see Example 3 and
Example 4).
A conditional block with a subconditional directive is different
from a nested conditional block. If the condition in the .IF is
not met, the inner conditional blocks are not assembled, but a
subconditional directive can cause a block to be assembled.
18.30.2 – Notes
o If a subconditional directive appears outside a conditional
assembly block, the assembler displays an error message.
o The alternate forms of .IF_FALSE, .IF_TRUE, and .IF_TRUE_FALSE
are .IFF, .IFT, and .IFTF.
o You cannot use .ELSE in the same conditional block as .IF_x.
18.30.3 – Examples
Example 1
Assume that symbol SYM is defined:
.IF DEFINED SYM ; Tests TRUE since SYM is defined.
. ; Assembles the following code.
.
.
.IF_FALSE ; Tests FALSE since previous
. ; .IF was TRUE. Does not
. ; assemble the following code.
.
.IF_TRUE ; Tests TRUE since SYM is defined.
. ; Assembles the following code.
.
.
.IF_TRUE_FALSE ; Assembles following code
. ; unconditionally.
.
.
.IF_TRUE ; Tests TRUE since SYM is defined.
. ; Assembles remainder of
. ; conditional assembly block.
.
.ENDC
Example 2
Assume that symbol X is defined and that symbol Y is not
defined:
.IF DEFINED X ; Tests TRUE since X is defined.
.IF DEFINED Y ; Tests FALSE since Y is not defined.
.IF_FALSE ; Tests TRUE since Y is not defined.
. ; Assembles the following code.
.
.
.IF_TRUE ; Tests FALSE since Y is not defined.
. ; Does not assemble the following
. ; code.
.
.ENDC
.ENDC
Example 3
Assume that symbol A is defined and that symbol B is not
defined:
.IF DEFINED A ; Tests TRUE since A is defined.
. ; Assembles the following code.
.
.
.IF_FALSE ; Tests FALSE since A is defined.
. ; Does not assemble the following
. ; code.
.
.IF NOT_DEFINED B ; Nested conditional directive
. ; is not evaluated.
.
.
.ENDC
.ENDC
Example 4
Assume that symbol X is not defined but symbol Y is defined:
.IF DEFINED X ; Tests FALSE since X is not defined.
. ; Does not assemble the following
. ; code.
.
.IF DEFINED Y ; Nested conditional directive
. ; is not evaluated.
.
.
.IF_FALSE ; Nested subconditional
. ; directive is not evaluated.
.
.
.IF_TRUE ; Nested subconditional
. ; directive is not evaluated.
.
.
.ENDC
.ENDC
18.31 – .IIF
Immediate conditional assembly block directive
Format
.IIF condition [,]argument(s), statement
18.31.1 – Parameters
condition
One of the legal condition tests defined for conditional assembly
blocks (see the description of .IF). The condition must be
separated from the arguments by a comma, space, or tab. If the
first argument can be a blank, the condition must be separated
from the arguments with a comma.
argument(s)
An expression or symbolic argument associated with the immediate
conditional assembly block directive. If the argument is an
expression, it cannot contain any undefined symbols. The
assembler converts relocatable arguments to absolute arguments
by discarding the relocatable portion of the expression and using
only the offset from the beginning of the psect. The arguments
must be separated from the statement by a comma.
statement
The statement to be assembled if the condition is satisfied.
18.31.2 – Description
.IIF provides a means of writing a one-line conditional assembly
block. The condition to be tested and the conditional assembly
block are expressed completely within the line containing the
.IIF directive. No terminating .ENDC statement is required or
allowed.
18.31.3 – Notes
o The assembler displays an error message if .IIF specifies a
condition test other than those which the assembler considers
valid, an illegal argument, or a null argument.
18.31.4 – Example
In the following example, the symbol EXAM is defined within the
source program:
.IIF DEFINED EXAM, BR ALPHA
This directive generates the following code:
BR ALPHA
18.32 – .INCLUDE
Include source file directive
Format
.INCLUDE quoted-literal
18.32.1 – Parameter
quoted-literal
The name of the source file to be included within double quotes.
If a logical name exists that is the same as the source file
name, specify the .M64 file extension to override the logical
name.
18.32.2 – Description
.INCLUDE indicates that the current input source file should be
suspended and that the specified file should be used. When that
file ends, the original source stream resumes, starting at the
line after .INCLUDE.
18.32.3 – Notes
o The assembler issues an error message if the file nesting
level exceeds 50.
18.32.4 – Example
.INCLUDE "file1.m64"
18.33 – .INSTRUCTION
Instruction directive
Format
.INSTRUCTION expression
18.33.1 – Parameter
expression
An absolute expression in the range of -2147483648 to 2147483647.
The expression cannot be relocatable, external, or complex.
18.33.2 – Description
The specified value is stored at the current location as an
instruction. You can use .INSTRUCTION to specify arbitrary
instructions. Similar to .LONG, .INSTRUCTION stores a longword
(32 bits) of data. Unlike .LONG, the assembler considers
.INSTRUCTION an instruction and allows its use in code psects.
18.33.3 – Notes
o You can only use this directive within code or mixed psects
(psects that have either the EXE or MIX attributes).
o If automatic data alignment is enabled within a mixed psect,
this directive aligns the current location counter to a
longword (32-bit) boundary before allocating storage.
o You can use this directive to store arbitrary, longword,
assembly-time constant data in a code section.
18.33.4 – Example
.INSTRUCTION 7
18.34 – .IRP
Indefinite repeat argument directive
Format
.IRP symbol,<argument list>
.
.
.
range
.
.
.
.ENDR
18.34.1 – Parameters
symbol
A formal argument that is successively replaced with the
specified actual arguments enclosed in angle brackets (<>). If
no formal argument is specified, the assembler displays an error
message.
<argument list>
A list of actual arguments enclosed in angle brackets and used
in expanding the indefinite repeat range. An actual argument
can consist of one or more characters. Multiple arguments must
be separated by a legal separator (comma, space, or tab). If no
actual arguments are specified, no action is taken.
range
The block of source text to be repeated once for each occurrence
of an actual argument in the list. The range can contain macro
definitions and repeat ranges. .MEXIT is legal within the range
and causes the current and remaining repetitions to be aborted.
18.34.2 – Description
.IRP replaces a formal argument with successive actual arguments
specified in an argument list. This replacement process occurs
during the expansion of the indefinite repeat block range. The
.ENDR directive specifies the end of the range.
.IRP is similar to a macro definition with only one formal
argument. At each successive expansion of the repeat block, this
formal argument is replaced with successive elements from the
argument list. The directive and its range are coded in line
within the source program. This type of macro definition and
its range do not require calling the macro by name, as do other
macros described in this section.
.IRP can appear either inside or outside another macro
definition, indefinite repeat block, or repeat block (see the
description of .REPEAT). The rules for specifying .IRP arguments
are the same as those for specifying macro arguments.
18.34.3 – Example
The macro definition is as follows:
.macro CHECK_PROCEDURE_KIND PROCEDURE_KIND
OK = 0 ; Assume procedure_kind is unknown
.irp REFERENCE_KIND,BOUND,NULL, REGISTER,STACK
.if identical, <PROCEDURE_KIND>, <REFERENCE_KIND>
OK = 1 ; Procedure_kind is known
.mexit ; No need to look further
.endc
.endr
.if eq, OK ; If unknown procedure kind
.error "Unknown procedure kind: PROCEDURE_KIND"
.endc
.endm CHECK_PROCEDURE_KIND
CHECK_PROCEDURE_KIND REGISTER
CHECK_PROCEDURE_KIND FOOZLE
The macro call and expansion of the previously defined macro is
as follows:
CHECK_PROCEDURE_KIND REGISTER
OK = 0 ; Assume procedure kind is unknown
.if identical,<REGISTER>,<BOUND>
.endc
.if identical,<REGISTER>,<NULL>
.endc
.if identical,<REGISTER>,<REGISTER>
OK = 1 ; Procedure kind is known
.mexit ; No need to look further
.if eq, OK ; If unknown procedure kind
.endc
CHECK_PROCEDURE_KIND FOOZLE
OK = 0 ; Assume procedure kind is unknown
.if identical,<FOOZLE>,<BOUND>
.endc
.if identical,<FOOZLE>,<NULL>
.endc
.if identical,<FOOZLE>,<REGISTER>
.endc
.if identical,<FOOZLE>,<STACK>
.endc
.if eq, OK ; If unknown procedure kind
.error "Unknown procedure kind: FOOZLE"
.endc
In this example the CHECK_PROCEDURE_KIND macro uses the
.IRP directive to iterate over a list of reference keywords
to determine if its argument matches one of the reference
keywords. If a match is not found, the macro displays an error
message.
18.35 – .IRPC
Indefinite repeat character directive
Format
.IRPC symbol,<STRING>
.
.
.
range
.
.
.
.ENDR
18.35.1 – Parameters
symbol
A formal argument that is successively replaced with the
specified characters enclosed in angle brackets (<>). If no
formal argument is specified, the assembler displays an error
message.
<STRING>
A sequence of characters enclosed in angle brackets and used in
the expansion of the indefinite repeat range. Although the angle
brackets are required only when the string contains separating
characters, their use is recommended for legibility.
range
The block of source text to be repeated once for each occurrence
of a character in the list. The range can contain macro
definitions and repeat ranges. .MEXIT is legal within the range.
18.35.2 – Description
.IRPC is similar to .IRP except that .IRPC permits single-
character substitution rather than argument substitution. On each
iteration of the indefinite repeat range, the formal argument is
replaced with each successive character in the specified string.
The .ENDR directive specifies the end of the range.
.IRPC is similar to a macro definition with only one formal
argument. At each expansion of the repeat block, this formal
argument is replaced with successive characters from the actual
argument string. The directive and its range are coded in line
within the source program and do not require calling the macro by
name.
.IRPC can appear either inside or outside another macro
definition, indefinite repeat block, or repeat block (see
description of .REPEAT).
18.35.3 – Example
The macro definition is as follows:
.macro X_COUNT ARG
COUNT = 0
.irpc CH,<ARG>
.iif identical,<CH>,<X>, COUNT = COUNT + 1
.endr
.endm X_COUNT
The macro call and expansion of the macro defined previously is
as follows:
X_COUNT XXFOOXBARXX
COUNT = 0
.irpc CH,<XXFOOXBARXX>
.iif identical,<CH>,<X>, COUNT = COUNT + 1
.endr
.iif identical,<X>,<X>, COUNT = COUNT + 1
.iif identical,<X>,<X>, COUNT = COUNT + 1
.iif identical,<F>,<X>, COUNT = COUNT + 1
.iif identical,<O>,<X>, COUNT = COUNT + 1
.iif identical,<O>,<X>, COUNT = COUNT + 1
.iif identical,<X>,<X>, COUNT = COUNT + 1
.iif identical,<B>,<X>, COUNT = COUNT + 1
.iif identical,<A>,<X>, COUNT = COUNT + 1
.iif identical,<R>,<X>, COUNT = COUNT + 1
.iif identical,<X>,<X>, COUNT = COUNT + 1
.iif identical,<X>,<X>, COUNT = COUNT + 1
.print "%integer(COUNT)"
%MACRO64-I-GENPRINT, Generated PRINT: 5
This example uses the .IRPC directive to iterate over the
characters in the argument to the X_COUNT macro. Each time
an argument character is X, the variable COUNT is incremented.
After the X_COUNT macro has expanded, the example uses the
%INTEGER() lexical operator to display the value of COUNT.
18.36 – .LIBRARY
Macro library directive
Format
.LIBRARY quoted-literal1 [quoted-literal2]
18.36.1 – Parameters
quoted-literal1
A string enclosed within double quotes that is the file
specification of a macro library. If a logical name exists and
it is the same as the macro library name, specify the .MLB file
extension to override the logical name.
quoted-literal2
An optional string enclosed within double quotes that specifies
a search list of file specifications where the assembler should
look for the specified macro library. The assembler successively
processes the search list in left-to-right order and attempts to
locate the specified macro library in each location specified in
the search list until the macro library is found. If the macro
library is not found, the assembler issues a diagnostic message.
If you omit the second argument to the .LIBRARY directive, the
assembler uses the following search list by default:
o The current device and directory
o The device and directory specified by the logical name
MACRO64$LIBRARY (if defined)
o The device and directory specified by the logical name
ALPHA$LIBRARY (if defined)
o The device and directory specified by the logical name
SYS$LIBRARY
Logical names may be defined as OpenVMS search lists.
18.36.2 – Description
.LIBRARY adds a name to the macro library list that is searched
whenever a .MCALL or an undefined opcode is encountered. The
libraries are searched in the reverse order in which they were
specified to the assembler.
If you omit any information from the macro-library-name file
description, default values are assumed. The device defaults to
your current default disk; the directory defaults to your current
default directory; the file type defaults to MLB.
18.36.3 – Example
.LIBRARY "MY_MACROS" 1
.LIBRARY "PROJ_MACROS" "PROJ:[MACRO],PROJ:[DEVELOPMENT]" 2
1 The first statement adds the macro library MY_MACROS.MLB
to the macro library list. The assembler first looks for
MY_MACROS.MLB in the current directory. If not found there,
the assembler next looks in the directory or directories
indicated by the MACRO64$LIBRARY logical name if it is
defined. If not found there or if MACRO64$LIBRARY is not
defined, the assembler next looks in the directory or
directories indicated by the ALPHA$LIBRARY logical name
if it is defined. If not found there or if ALPHA$LIBRARY is
not defined, the assembler next looks in the directory or
directories indicated by the SYS$LIBRARY logical name. If
not found there, the assembler issues a diagnostic message.
2 The second statement adds the macro library PROJ_MACROS.MLB
to the macro library list. The assembler first looks for
PROJ_MACROS.MLB in the PROJ:[MACRO] directory. If not found
there, the assembler next looks in the PROJ:[DEVELOPMENT]
directory. If not found there, the assembler issues a
diagnostic message.
18.37 – .LINKAGE PAIR
Linkage directive
Format
.LINKAGE_PAIR name
18.37.1 – Parameter
name
The name of the procedure descriptor, possibly defined in a
different module of the routine to which linkage is required.
18.37.2 – Description
.LINKAGE_PAIR causes a linkage pair to be stored at the current
location counter. A linkage pair consists of two quadwords. The
first quadword is the code entry point of the routine indicated
by the specified identifier. The second quadword is the address
of the procedure descriptor of the routine indicated by the
specified identifier. The second quadword is also called the
procedure value. The specified name should reference a procedure
descriptor that is either defined within the assembly unit or
that becomes defined at the time the program is linked.
18.37.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to an octaword (128-bit) boundary
before allocating storage.
18.37.4 – Example
.LINKAGE_PAIR A ; Code address A followed by address of
; procedure descriptor A
18.38 – .LIST
Listing directive
Format
.LIST [argument-list]
18.38.1 – Parameter
argument-list
One or more of the symbolic arguments You can use either the long
form or the short form of the arguments. If multiple arguments
are specified, separate them with commas, spaces, or tabs.
18.38.2 – Description
.LIST is equivalent to .SHOW. See the description of .SHOW for
more information.
18.39 – .LOCAL CODE ADDRESS
Local code address storage directive
Format
.LOCAL_CODE_ADDRESS name-list
18.39.1 – Parameter
name-list
A list of symbols separated by commas. Each symbol references a
procedure descriptor defined in the current module.
18.39.2 – Description
.LOCAL_CODE_ADDRESS causes the code addresses of the specified
identifiers to be placed at the current psect and current
location counter. The specified identifier must reference a
procedure descriptor defined within the module. The .LOCAL_
CODE_ADDRESS directive, rather than the .CODE_ADDRESS directive,
must be used with procedure descriptor names that are local (as
opposed to global) to the assembly unit.
18.39.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a quadword (64-bit) boundary
before allocating storage.
18.39.4 – Example
.PROCEDURE_DESCRIPTOR P1,C1
.BLKQ 1
.LOCAL_CODE_ADDRESS P1 ; Code address
; of P1...address of C1...
; is stored here.
18.40 – .LOCAL LINKAGE PAIR
Local linkage directive
Format
.LOCAL_LINKAGE_PAIR name
18.40.1 – Parameter
name
The name of a procedure descriptor of the routine to which
linkage is required. The specified procedure descriptor must
be defined in the current module.
18.40.2 – Description
.LOCAL_LINKAGE_PAIR causes a linkage pair to be stored at
the current location counter. A linkage pair consists of a
code address and the address of the specified identifier. The
specified name must reference a procedure descriptor that is
defined within the assembly unit.
18.40.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to an octaword (128-bit) boundary
before allocating storage.
18.40.4 – Example
.PROCEDURE_DESCRIPTOR P1,CA1
.
.
.
.LOCAL_LINKAGE_PAIR P1 ; Code address CA1 followed by
; procedure descriptor address P1.
18.41 – .LOCAL PROCEDURE DESCRIPTOR
Procedure descriptor labeling directive
Format
.LOCAL_PROCEDURE_DESCRIPTOR pd-name, ca-name
18.41.1 – Parameters
pd-name
The name of the procedure descriptor. This name can be up to 31
characters long. It cannot be a temporary label.
ca-name
The name of the code address that corresponds to the procedure
descriptor. This name must be defined later in the program as
a label in a psect that has either the EXE or MIX attribute, or
both. This name can be up to 31 characters long. It cannot be a
temporary label.
18.41.2 – Description
.LOCAL_PROCEDURE_DESCRIPTOR defines a bivalued local identifier
that is used to represent a local routine. The first value
is the procedure value, which is the address of the procedure
descriptor. This value is defined as the current location counter
at the point where you use the .LOCAL_PROCEDURE_DESCRIPTOR
directive. The second value is the code address, which is
the code entry-point address of the procedure. This value is
defined by the second argument to the .LOCAL_PROCEDURE_DESCRIPTOR
directive. No storage is allocated.
18.41.3 – Notes
o See the OpenVMS Calling Standard for a full description of
procedure descriptors.
o You must specify .LOCAL_PROCEDURE_DESCRIPTOR before the code
of the routine it describes.
o See the description for the $PROCEDURE_DESCRIPTOR and $ROUTINE
library macros. These macros define the procedure identifier
and define the storage for the procedure descriptor.
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a quadword (64-bit) boundary
before defining the procedure identifier.
18.41.4 – Example
.LOCAL_PROCEDURE_DESCRIPTOR LP1,C1
18.42 – .LONG
Longword storage directive
Format
.LONG expression-list
18.42.1 – Parameter
expression-list
One or more expressions separated by commas.
18.42.2 – Description
.LONG generates successive longwords (4 bytes) of data in the
object module. The assembler truncates on the left of an integer
or external value.
18.42.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a longword (32-bit) boundary
before allocating storage.
o You can define a 32-bit address item using macros and the
.LONG directive. For example:
.macro address_32 item
.long item
.endm address_32
18.42.4 – Example
.LONG 4 ; Places 4 in 4 bytes of storage.
18.43 – .MACRO
Macro definition directive
Format
.MACRO macro-name [formal-argument-list]
.
.
.
range
.
.
.
.ENDM [macro-name]
18.43.1 – Parameters
macro-name
The name of the macro to be defined; this name can be any legal
symbol up to 31 characters long.
formal-argument-list
The symbols, separated by commas, to be replaced by the actual
arguments in the macro call.
range
The source text to be included in the macro expansion.
18.43.2 – Description
.MACRO begins the definition of a macro. It gives the macro name
and a list of formal arguments. The .MACRO directive is followed
by the source text to be included in the macro expansion. The
.ENDM directive specifies the end of the range.
Macro names do not conflict with user-defined symbols. Both a
macro and a user-defined symbol can have the same name.
When the assembler encounters a .MACRO directive, it adds the
macro name to its macro name table and stores the source text
of the macro (up to the matching .ENDM directive). No other
processing occurs until the macro is expanded.
The symbols in the formal argument list are associated with the
macro name and are limited to the scope of the definition of that
macro. For this reason, the symbols that appear in the formal
argument list can also appear elsewhere in the program.
18.43.3 – Notes
o If a macro has the same name as an Alpha opcode, the macro
is used instead of the instruction. This feature allows you to
temporarily redefine an opcode.
o You can redefine a macro by using a .MACRO directive with the
same name as in a previous macro definition. Therefore, the
previous macro definition is implicitly deleted and the new
macro definition supersedes the previous definition. See the
.MDELETE directive for more information on macro deletion.
o You can nest a macro definition within another macro
definition. The inner macro is not defined until the outer
macro is invoked.
o You can nest a macro invocation so that one macro can invoke
another. The assembler supports nested macro invocations to a
depth of 1000. If a macro invokes itself, either directly or
indirectly, it is recursive. Recursive macros must specify a
basis-step in order to avoid infinite recursion. A basis-step
is a macro exit condition that will eventually cause the macro
to exit, which ends the recursion (see Example 3).
18.43.4 – Examples
Example 1
This example shows how macro definitions and invocations may
be nested. It also shows examples of the various forms of
parameter passing.
.MACRO OP1 A,B=R4,?C
C: ADDL R2, B, R3
.MACRO OP'B
TRAPB
.ENDM OP'B
ADDL A, R2, R3
OP'B
.MDELETE OP'B
.ENDM OP1
When OP1 is invoked "OP1 R0", the text expands to:
33000$: ADDL R2, R4, R3
.MACRO OPR4
TRAPB
.ENDM
ADDL R0, R2, R3
OPR4
.MDELETE OPR4
Processing this text will cause OPR4 to be expanded to TRAPB;
the final text will be:
33000$: ADDL R2, R4 R3
ADDL R0, R2, R3
TRAPB
Example 2
The following example shows macro redefinition:
.MACRO INITIALIZE
.MACRO INITIALIZE ;Redefine to nothing
.ENDM INITIALIZE
X=0
Y=1
Z=-1
.ENDM INITIALIZE
Note that while the redefined version of the macro immediately
supersedes the previous definition in any subsequent
invocation, the invocation of the original definition expands
to completion.
Example 3
This example shows a recursive macro:
.MACRO FACTORIAL N
.IF EQUAL <N>,0 ;Basis step; stop at zero
F=1
.ELSE
FACTORIAL <N-1>
F = F * <N>
.ENDC
.ENDM FACTORIAL
18.44 – .MCALL
Macro call directive
Format
.MCALL macro-name-list
18.44.1 – Parameter
macro-name-list
A list of macros to be defined for this assembly. Separate the
macro names with commas.
18.44.2 – Description
.MCALL specifies the names of the system and user-defined macros
that are required to assemble the source program but are not
defined in the source file.
If any named macro is not found upon completion of the search
(that is, if the macro is not defined in any of the macro
libraries), the assembler displays an error message.
18.44.3 – Notes
o Using the .MCALL directive is optional unless the macro name
is the same as an opcode or assembler directive. The assembler
automatically searches for a library macro when it encounters
an identifier that is not an opcode or directive in the
opcode field. If your macro name is the same as an opcode or
directive, you must use the .MCALL directive. You can also use
the .MCALL directive in your program to document which macros
are used by your program.
18.44.4 – Example
.MCALL TRAPB ; Substitute macro in library for
; TRAPB instruction
18.45 – .MDELETE
Macro deletion directive
Format
.MDELETE macro-name-list
18.45.1 – Parameter
macro-name-list
A list of macros whose definitions are to be deleted. You can
separate the macros with commas or spaces.
18.45.2 – Description
.MDELETE deletes the definitions of specified macros.
.MDELETE completely deletes the macro. If you delete a macro that
is currently expanding (such as a macro that deletes itself),
the macro name is immediately removed from the macro name table
and the macro is marked for deletion. When the macro finishes
expanding, it is deleted.
18.45.3 – Example
.MACRO FOO
.PRINT "In macro FOO"
.ENDM FOO
FOO
.MDELETE FOO
18.46 – .MEXIT
Macro exit directive
Format
.MEXIT
18.46.1 – Description
.MEXIT terminates a macro expansion before the end of the macro.
Termination is the same as if .ENDM were encountered. You can
also use the directive within repeat blocks. .MEXIT is useful
in conditional expansion of macros and repeat blocks because it
bypasses the complexities of nested conditional directives and
alternate assembly paths.
18.46.2 – Notes
o When .MEXIT occurs in a repeat block, the assembler terminates
the current repetition of the range and suppresses further
expansion of the repeat range.
o When macros or repeat blocks are nested, .MEXIT exits to the
next higher level of expansion.
o If .MEXIT occurs outside a macro definition or a repeat block,
the assembler displays an error message.
18.46.3 – Examples
Example 1
The following macro definition uses the .MEXIT directive
to exit the current macro when it has finished processing a
particular kind of argument:
.macro STORE REG, LOCATION
.if identical,<REG>,<FP>
STQ REG, LOCATION
.mexit
.endc
.if identical,<REG>,<SP>
STQ REG, LOCATION
.mexit
.endc
.if identical,<%extract(0,1,<REG>)>,<R>
STQ REG, LOCATION
.mexit
.endc
.if identical,<%extract(0,1,<REG>)>,<F>
STT REG, LOCATION
.mexit
.endc
.error "Register argument is not a register"
.endm STORE
Example 2
In this example, the STORE macro (as defined in Example 1)
attempts to recognize its REG argument as either FP, SP, an
integer register (a register with R as its first letter),
or a floating-point register (a register with F as its first
letter). The following example show two expansions of the STORE
macro:
STORE R1, 0(SP)
.if identical,<R1>,<FP>
.endc
.if identical,<R1>,<SP>
.endc
.if identical,<%extract(0,1,<R1>)>, <R>
.if identical,<R>,<R>
STQ R1, 0(SP)
.mexit
STORE 24(SP), 16(SP)
.if identical,<24(SP)>,<FP>
.endc
.if identical,<24(SP)>,<SP>
.endc
.if identical,<%extract(0,1,<24(SP)>)>,<R>
.if identical,<2>,<R>
.endc
.if identical, <%extract(0,1<24(SP)>)>,<F>
.if identical,<2>,<F>
.endc
.error "Register argument is not a register"
The first call of the STORE macro stores R1 at 0(SP). The
STORE macro determines to do an integer store by recognizing
the letter R as the first letter of the register name. After
it has done so, it abandons further expansion of the macro
using the .MEXIT directive. The second invocation attempts to
store 24(SP) at 16(SP). Since the STORE macro cannot identify
24(SP) as a legitimate register in any of the four forms it
recognizes, the STORE macro does not attempt to store the
REG argument, and does not abandon expansion with the .MEXIT
directive. Instead, the STORE macro expands and issues a
diagnostic message.
18.47 – .NARG
Number of arguments directive
Format
.NARG symbol
18.47.1 – Parameter
symbol
A symbol that is assigned a value equal to the number of
positional arguments in the macro call.
18.47.2 – Description
.NARG determines the number of arguments in the current macro
call.
.NARG counts all the positional arguments specified in the macro
call, including null arguments (specified by adjacent commas).
The value assigned to the specified symbol does not include
any keyword arguments or any formal arguments that have default
values.
18.47.3 – Notes
o If .NARG appears outside a macro, the assembler displays an
error message.
18.47.4 – Examples
Example 1
The macro definition is as follows:
.MACRO CNT_ARG A1,A2,A3,A4,A5,A6,A7,A8,A9=DEF9,A10=DEF10
.NARG COUNTER ; COUNTER is set to no. of ARGS
.WORD COUNTER ; Store value of COUNTER
.ENDM CNT_ARG
Example 2
The macro calls and expansions of the macro previously defined
are as follows:
CNT_ARG TEST,FIND,ANS ; COUNTER will = 3
.NARG COUNTER ; COUNTER is set to no. of ARGS
.WORD COUNTER ; Store value of COUNTER
CNT_ARG ; COUNTER will = 0
.NARG COUNTER ; COUNTER is set to no. of ARGS
.WORD COUNTER ; Store value of COUNTER
CNT_ARG TEST,A2=SYMB2,A3=SY3 ; COUNTER will = 1
.NARG COUNTER ; COUNTER is set to no. of ARGS
.WORD COUNTER ; Store value of COUNTER
; Keyword arguments are not counted
CNT_ARG ,SYMBL,, ; COUNTER will = 4
.NARG COUNTER ; COUNTER is set to no. of ARGS
.WORD COUNTER ; Store value of COUNTER
; Null arguments are counted
18.48 – .NCHR
Number of characters directive
Format
.NCHR symbol,<string>
18.48.1 – Parameters
symbol
A symbol that is assigned a value equal to the number of
characters in the specified character string.
<string>
A sequence of printable characters. Delimit the character
string with angle brackets (<>) (or a character preceded by a
circumflex (^)) only if the specified character string contains
a legal separator (comma, space, or tab) or a
semicolon (;).
18.48.2 – Description
.NCHR determines the number of characters in a specified
character string. It can appear anywhere in an MACRO-64 program
and is useful in calculating the length of macro arguments.
18.48.3 – Notes
o You can use the %LENGTH lexical operator instead of the .NCHR
directive.
18.48.4 – Examples
Example 1
The macro definition is as follows:
.MACRO CHAR MESS ; Define MACRO
.NCHR CHRCNT,<MESS> ; Assign value to CHRCNT
.WORD CHRCNT ; Store value
.ASCII "MESS" ; Store characters
.ENDM CHAR ; Finish
Example 2
The macro calls and expansions of the macro previously defined
are as follows:
CHAR <HELLO> ; CHRCNT will = 5
.NCHR CHRCNT,<HELLO> ; Assign value to CHRCNT
.WORD CHRCNT ; Store value
.ASCII "HELLO" ; Store characters
CHAR <14, 75.39 4> ; CHRCNT will = 12(dec)
.NCHR CHRCNT,<14, 75.39 4> ; Assign value to CHRCNT
.WORD CHRCNT ; Store value
.ASCII "14, 75.39 4" ; Store characters
18.49 – .NLIST
Listing exclusion directive
Format
.NLIST [argument-list]
18.49.1 – Parameter
argument-list
One or more of the symbolic arguments Use either the long form
or the short form of the arguments. If you specify multiple
arguments, separate them with commas, spaces, or tabs.
18.49.2 – Description
.NLIST is equivalent to .NOSHOW. See the description of .SHOW for
more information.
18.50 – .NOSHOW
Listing exclusion directive
Format
.NOSHOW [argument-list]
18.50.1 – Parameter
argument-list
One or more of the symbolic arguments listed in the description
of .SHOW. Use either the long form or the short form of the
arguments. If you specify multiple arguments, separate them with
commas, spaces, or tabs.
18.50.2 – Description
.NOSHOW specifies listing control options. See the description of
.SHOW for more information.
18.51 – .OCTA
Octaword storage directive
Format
.OCTA expression-list
18.51.1 – Parameter
expression-list
A list of constant values separated by commas. Each value results
in a 64-bit value being sign-extended to 128 bits and stored in
an octaword.
18.51.2 – Description
.OCTA generates 128 bits (16 bytes) of binary data.
18.51.3 – Notes
o The low quadword contains the specified constant value.
o The high quadword contains the sign extension of the specified
constant value. That is, the high quadword contains 0 if the
specified value is positive, and it contains all bits set to 1
if the specified value is negative.
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to an octaword (128-bit) boundary
before allocating storage.
18.51.4 – Example
.OCTA 0 ; OCTA 0
.OCTA ^X01234ABCD5678F9 ; OCTA hex value specified
.OCTA VINTERVAL ; VINTERVAL has 64-
bit value,
; sign-extended
18.52 – .ODD
Odd location counter alignment directive
Format
.ODD
18.52.1 – Description
.ODD ensures that the current value of the location counter is
odd by adding 1 if the current value is even. If the current
value is already odd, no action is taken.
18.52.2 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
18.53 – .PACKED
Packed decimal string storage directive
Format
.PACKED decimal-string[,symbol]
18.53.1 – Description
.PACKED is supplied as a library macro with MACRO-64.
18.54 – .PAGE
Page ejection directive
Format
.PAGE
18.54.1 – Description
.PAGE forces a new page in the listing. The directive itself is
also printed in the listing and begins the new page.
.PAGE in a macro definition is ignored. The paging operation is
performed only during macro expansion. If the .PAGE directive
occurs during macro expansion, text beginning with the original
macro invocation line appears at the top of a new page.
18.54.2 – Example
.MACRO SKIP ; macro definition with .PAGE
.PAGE ;
.ENDM SKIP ;
.PSECT A,NOEXE ;
.BLKW 10 ;
SKIP ; In the listing file, a form feed
; will be inserted here
18.55 – .PRINT
Assembly message directive
Format
.PRINT quoted-literal
18.55.1 – Parameter
quoted-literal
The string of characters enclosed in quotes are displayed when
encountered during assembly.
18.55.2 – Description
.PRINT causes the assembler to display an informational message.
The message consists of the string.
18.55.3 – Notes
o .PRINT, .WARN, and .ERROR are directives that display
messages. You can use these to display information indicating
unexpected or important conditions within the assembly.
o This directive also accepts VAX MACRO syntax. See the
VAX MACRO and Instruction Set Reference Manual for details.
18.55.4 – Example
.PRINT "Questionable usage"
^
%MACRO64-I-GENPRINT, Generated PRINT: Questionable usage
at line number 3 in file DISK$:[TEST]PRINT.M64;2
18.56 – .PROCEDURE DESCRIPTOR
Procedure descriptor labeling directive
Format
.PROCEDURE_DESCRIPTOR pd-name, ca-name
18.56.1 – Parameters
pd-name
The name of the procedure descriptor. This name can be up to 31
characters long. It cannot be a temporary label.
ca-name
The name of the code address that corresponds to the procedure
descriptor. This name must be defined later in the program as
a label in a psect that has either the EXE or MIX attribute, or
both. This name can be up to 31 characters long. It cannot be a
temporary label.
18.56.2 – Description
.PROCEDURE_DESCRIPTOR defines a bivalued global identifier
that is used to represent a global routine. The first value
is the procedure value, which is the address of the procedure
descriptor. This value is defined as the current location counter
at the point where you use the .PROCEDURE_DESCRIPTOR directive.
The second value is the code address, which is the code entry-
point address of the procedure. This value is defined by the
second argument to the .PROCEDURE_DESCRIPTOR directive. No
storage is allocated.
18.56.3 – Notes
o See the OpenVMS Calling Standard for a full description of
procedure descriptors.
o You must specify .PROCEDURE_DESCRIPTOR before the code of the
routine it describes.
o See the descriptions for the $PROCEDURE_DESCRIPTOR and
$ROUTINE library macros. These macros define the procedure
identifier and define the storage for the procedure
descriptor.
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a quadword (64-bit) boundary
before defining the procedure identifier.
18.57 – .PSECT
Program sectioning directive
Format
.PSECT program-section-name[,argument-list]
18.57.1 – Parameters
program-section-name
The name of the program section (psect).
argument-list
A list containing the program section attributes and the program
section alignment. Program sections are aligned when you specify
an integer in the range of 0 to 16 or one of the five keywords
listed in the following table. If you specify an integer, the
program section is linked to begin at the next virtual address
that is a multiple of two raised to the power of the integer. If
you specify a keyword, the program section is linked to begin at
the next virtual address that is a multiple of the corresponding
value listed in the following table:
KeywordSize (in Bytes)
BYTE 20 = 1
WORD 21 = 2
LONG 22 = 4
QUAD 23 = 8
OCTA 24 = 16
QUAD is the default.
Table 8 Program Section Attributes
AttribuFunction
ABS Absolute-The program section has an absolute address. An
absolute program section contributes no binary code to
the image, so its byte allocation request to the linker
is 0. You cannot store initial values in an absolute
program section with directives such as .BYTE, .WORD,
.LONG, .QUAD. Usually the .BLKx directives are used in
conjunction with label definitions within an absolute
program section to define symbolic offsets within a
structure. Compare this attribute with its opposite, REL.
CON Concatenate-Program sections with the same name and
attributes (including CON) from other modules are
concatenated into one program section at link time. Their
contents are concatenated in the order in which the linker
acquires them. The allocated virtual address space is the
sum of the individual requested allocations. Compare this
attribute with its opposite, OVL.
EXE Executable-The program section contains instructions.
This attribute provides the capability of separating
instructions from read-only and read/write data. The
linker uses this attribute in gathering program sections
and in verifying that the transfer address is in an
executable program section. The assembler only allows
you to place instructions in a program section that has
either or both the EXE or MIX attributes. Compare this
attribute with its opposite, NOEXE.
GBL Global-Program sections that have the same name and
attributes will be combined at link time into a single
program section even when the individual program sections
are in different clusters. This attribute is specified
for Fortran COMMON block program sections. Compare this
attribute with its opposite, LCL.
LCL Local-The program section is restricted to its cluster.
Compare this attribute with its opposite, GBL.
MIX Mix-The program section can contain both data and
instructions. The MIX and NOMIX attributes are assembly-
time attributes that only affect assembler processing.
The MIX and NOMIX attributes do not appear in the object
module and do not affect linker processing. To mix
instructions and data in the same psect, you must specify
the MIX attribute. The NOMIX attribute is the default. If
you choose to use instructions in a NOEXE psect, or use
data directives in an EXE psect, you must specify the MIX
attribute. The following limitations apply when using the
MIX attribute:
o Optimizations and alignment of code labels are not
performed. Optimizations and code-label alignment are
not performed on instructions placed in a MIX psect,
regardless of whether the .ENABLE/.DISABLE options have
been set, or if the command-line /OPTIMIZATION and
/ALIGNMENT=CODE options have been specified.
o Limited debugging information is provided. No PC-line
(program counter) correlation information is generated
for the instructions placed in a MIX psect.
o The listing file includes only binary encoded
instructions. All instructions that are placed in a
MIX psect appear in the machine-code portion of the
listing file, in their binary encoded instruction form
as a data initializer to the .LONG data directive.
There are no restrictions on data directives. Compare this
attribute with its opposite, NOMIX.
NOEXE Not Executable-The program section contains data only; it
does not contain instructions. The assembler only allows
you to place data allocations in a program section that
has either or both the NOEXE and MIX attributes. Compare
this attribute with its opposite, EXE.
NOMIX The default attribute when you use the .PSECT directive.
Compare this attribute with its opposite, MIX.
NOPIC Non-Position-Independent Content-The program section is
assigned to a fixed location in virtual memory (when it
is in a shareable image). Compare this attribute with its
opposite, PIC.
NORD Nonreadable-Reserved for future use. Compare this
attribute with its opposite, RD.
NOSHR No Share-The program section is reserved for private use
at execution time by the initiating process. Compare this
attribute with its opposite, SHR.
NOWRT Nonwritable-The contents of the program section cannot
be altered (written into) at execution time. Compare this
attribute with its opposite, WRT.
OVR Overlay-Program sections with the same name and attributes
(including OVR) from other modules receive the same
relocatable base address in memory at link time. The
allocated virtual address space is the requested
allocation of the largest overlaying program section.
Compare this attribute with its opposite, CON.
PIC Position-Independent Content-The program section can be
relocated; that is, it can be assigned to any memory area
(when it is in a shareable image). Compare this attribute
with its opposite, NOPIC.
RD Readable-Reserved for future use. Compare this attribute
with its opposite, NORD.
REL Relocatable-The linker assigns the program section a
relocatable base address. The contents of the program
section can be code or data. Compare this attribute with
its opposite, ABS.
SHR Share-The program section can be shared at execution time
by multiple processes. This attribute is assigned to a
program section that can be linked into a shareable image.
Compare this attribute with its opposite, NOSHR.
WRT Write-The contents of the program section can be altered
(written into) at execution time. Compare this attribute
with its opposite, NOWRT.
Table 9 Default Program Section Attributes
Default
Attribute Opposite Attribute
CON OVR
EXE NOEXE
LCL GBL
NOMIX MIX
NOPIC PIC
NOSHR SHR
RD NORD
REL ABS
WRT NOWRT
18.57.2 – Description
.PSECT defines a program section and its attributes and refers to
a program section after it is defined. Use program sections to do
the following:
o Develop modular programs.
o Separate instructions from data.
o Allow different modules to access the same data.
o Protect read-only data and instructions from being modified.
o Identify sections of the object module to the linker and the
debugger.
o Control the order in which program sections are stored in
virtual memory.
When the assembler encounters a .PSECT directive that specifies
a new program section name, it creates a new program section
and stores the name, attributes, and alignment of the program
section. The assembler includes all data or instructions that
follow the .PSECT directive in that program section until it
encounters another .PSECT directive. The assembler starts all
program sections at a relative location counter of 0.
The assembler does not automatically define program sections.
Any code or data placed before the first .PSECT directive in the
source code produces an assembly error.
If the assembler encounters a .PSECT directive that specifies
the name of a previously defined program section, it stores the
new data or instructions after the last entry in the previously
defined program section, even with program sections that have
the OVR attribute. (OVR program sections from separate modules
are overlaid by the linker. The OVR attribute does not affect
how multiple contributions to a psect are processed within a
single assembly unit.) You need not relist the attributes when
continuing a program section, but any attributes that are listed
must be the same as those previously in effect for the program
section. A continuation of a program section cannot contain
attributes conflicting with those specified, or defaulted, in
the original .PSECT directive.
The attributes listed in the .PSECT directive describe the
contents of the program section. Except for the EXE and NOEXE
attributes, the assembler does not check to ensure that the
contents of the program section actually adhere to the attributes
listed. However, the assembler and the linker do check that
all program sections with the same name have exactly the same
attributes. The assembler and linker display an error message if
the program section attributes are not consistent.
Program section names are independent of local symbol, global
symbol, and macro names. You can use the same symbolic name
for a program section and for a local symbol, global symbol,
or macro name. You may want to use unique names for clarity and
maintainability.
18.57.3 – Notes
o The .ALIGN directive cannot specify an alignment greater than
that of the current program section; consequently, .PSECT
should specify the largest alignment needed in the program
section.
o For efficiency of execution and ease of programming, an
alignment of quadword or larger is recommended for all program
sections that have quadword data.
18.57.4 – Example
.PSECT A,QUAD,EXE ; Code psect
18.58 – .QUAD
Quadword storage directive
Format
.QUAD expression-list
18.58.1 – Parameter
expression-list
One or more expressions separated by commas.
18.58.2 – Description
.QUAD generates 64 bits (8 bytes) of binary data.
18.58.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a quadword (64-bit) boundary
before allocating storage.
18.58.4 – Example
A:: .QUAD 4
18.59 – .REPEAT
Repeat block directive
Format
.REPEAT expression
.
.
.
range
.
.
.
.ENDR
18.59.1 – Parameters
expression
An expression whose value controls the number of times the range
is to be assembled within the program. When the expression is
less than or equal to 0, the repeat block is not assembled. The
expression must be absolute or relocatable and must not contain
any undefined symbols. The assembler converts a relocatable value
to the relative offset within the psect.
range
The source text to be repeated the number of times specified by
the value of the expression. The repeat block can contain macro
definitions or other repeat blocks. .MEXIT is legal within the
range and causes the current and all succeeding repetitions to be
aborted.
18.59.2 – Description
.REPEAT repeats a block of code a specified number of times in
line with other source code. The .ENDR directive specifies the
end of the range.
18.59.3 – Notes
The alternate form of .REPEAT is .REPT.
18.59.4 – Examples
Example 1
The following macro definition uses the .REPEAT directive to
store an ASCII string a specified number of times, followed by
a 0 byte:
.MACRO COPIES STRING,NUM
.REPEAT NUM
.ASCII "STRING"
.ENDR
.BYTE 0
.ENDM COPIES
Example 2
The following macro call stores five copies of the string
ABCDEF. This example is divided into four parts:
Macro invocation:
COPIES <ABCDEF>,5
Macro expansion of .REPEAT invocation:
.REPEAT 5
.ASCII "ABCDEF"
.ENDR
.REPEAT expansion:
.ASCII "ABCDEF"
.ASCII "ABCDEF"
.ASCII "ABCDEF"
.ASCII "ABCDEF"
.ASCII "ABCDEF"
End of macro expansion:
.BYTE 0
Example 3
The following macro call stores three copies of the string How
Many Times. This example is divided into four parts:
Macro invocation:
VARB = 3
COPIES <How Many Times>,VARB
Macro expansion of .REPEAT invocation:
.REPEAT VARB
.ASCII "How Many Times"
.ENDR
.REPEAT expansion:
.ASCII "How Many Times"
.ASCII "How Many Times"
.ASCII "How Many Times"
End of macro expansion:
.BYTE 0
18.60 – .RESTORE PSECT
Restore previous program section context directive
Format
.RESTORE_PSECT
.RESTORE
18.60.1 – Description
.RESTORE_PSECT retrieves the program section from the top of
the program section context stack, an internal stack in the
assembler. If the stack is empty when .RESTORE_PSECT is issued,
the assembler displays an error message. When .RESTORE_PSECT
retrieves a program section, it restores the current location
counter to the value it had when the program section was saved.
The maximum stack level is 50. See the description of .SAVE_PSECT
for more information.
18.60.2 – Notes
o The alternate form of .RESTORE_PSECT is .RESTORE.
o You cannot use .RESTORE_PSECT to overwrite previous data-
storage initializations. In the following example, MACRO-
64 attempts to store 42 over 43 and fails, resulting in a
diagnostic:
.PSECT A
.SAVE PSECT
.PSECT A
.QUAD 43
.RESTORE PSECT
.QUAD 42
18.60.3 – Example
.PSECT A,QUAD,NOEXE
A1: .WORD 5
A2: .QUAD 6
.SAVE_PSECT ; Saves psect A context
.PSECT B,QUAD,NOEXE
B1: .WORD 6
.RESTORE_PSECT ; Return A location counter
A3: .WORD 5
.PSECT B,QUAD,NOEXE
1$: .WORD 5
.SAVE LOCAL_BLOCK ; Saves psect B context and temporary
; label context
.PSECT C,NOEXE
1$: .WORD 6
.RESTORE_PSECT ; Restores psect B and saves
; label context
.ADDRESS 1$ ; References the address of
; psect B temporary label 1$
18.61 – .SAVE PSECT
Save current program section context directive
Format
.SAVE_PSECT [LOCAL_BLOCK]
.SAVE [LOCAL_BLOCK]
18.61.1 – Description
.SAVE_PSECT stores the current program section context on the
top of the program section context stack, an internal assembler
stack. It leaves the current program section context in effect.
The program section context stack can hold up to 50 entries.
Each entry includes the value of the current location counter
and the maximum value assigned to the location counter in the
current program section. If the stack is full when .SAVE_PSECT is
encountered, an error occurs.
If the LOCAL_BLOCK option is specified, the current temporary
label block is saved with the current program section context.
.SAVE_PSECT and .RESTORE_PSECT are especially useful in macros
that define program sections. See the description of .RESTORE_
PSECT for an example using .SAVE_PSECT.
18.61.2 – Notes
o The alternate form of .SAVE_PSECT is .SAVE.
18.62 – .S FLOATING
Single-precision IEEE floating-point arithmetic directive
Format
.S_FLOATING floating-point-number-list
18.62.1 – Parameter
floating-point-number-list
A list of IEEE single-precision floating-point constants
separated by commas.
18.62.2 – Description
.S_FLOATING evaluates the specified floating-point constants and
stores the results in the object module. .S_FLOATING generates
32-bit, single-precision, floating-point data (1 bit of sign, 8
bits of exponent, and 23 bits of fractional significance). See
the description of .T_FLOATING for information on storing double-
precision floating-point IEEE numbers and the descriptions of
.D_FLOATING, .F_FLOATING, and .G_FLOATING for descriptions of
other floating-point numbers.
18.62.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a longword (32-bit) boundary
before allocating storage.
18.62.4 – Example
.S_FLOATING 2.0,3.0,4.405
18.63 – .SHOW
Listing inclusion and exclusion directives
Format
.SHOW [argument-list]
.NOSHOW [argument-list]
18.63.1 – Parameter
[argument-list]
You can use either the long form or the short form of the
arguments. If you specify multiple arguments, you must separate
them by commas. If any argument is not specifically included in
a listing control statement, the assembler assumes its default
value (show or noshow) throughout the source program.
Table 10 .SHOW and .NOSHOW Symbolic Arguments
Short
Long Form Form Default Function
BINARY MEB Noshow Lists macro and repeat block
expansions that generate binary
code. BINARY is a subset of
EXPANSIONS.
CONDITIONALS CND Noshow Lists unsatisfied conditional
code associated with the
conditional assembly directives.
EXPANSIONS ME Noshow Lists macro and repeat range
expansions.
LIBRARY None Noshow Includes the macro definitions in
a library in the listing.
INCLUDE None Noshow Lists include file text in the
listing file.
18.63.2 – Description
.SHOW and .NOSHOW specify listing control options in the source
text of a program. You can use .SHOW and .NOSHOW with or without
an argument list.
.SHOW and .NOSHOW control the listing of the source lines that
are in conditional assembly blocks (see the description of .IF),
macros, and repeat blocks. When you use them without arguments,
these directives alter the listing level count. The listing level
count is initialized to 0. Each time .SHOW appears in a program,
the listing level count is incremented; Each time .NOSHOW appears
in a program, the listing level count is decremented.
When the listing level count is negative, the listing is
suppressed unless the line contains an error. Conversely, when
the listing level count is positive, the listing is generated.
When the count is 0, the line is either listed or suppressed,
depending on the value of the listing control symbolic arguments.
18.63.3 – Notes
o The listing level count allows macros to be listed
selectively; a macro definition can specify .NOSHOW at the
beginning to decrement the listing count and can specify .SHOW
at the end to restore the listing count to its original value.
o The alternate forms of .SHOW and .NOSHOW are .LIST and .NLIST.
o The initial setting for each .LIST/.SHOW option (except
BINARY) is obtained from the command-line setting using the
/SHOW qualifier.
o The /[NO]SHOW=BINARY option overrides the .[NO]SHOW BINARY
directive.
18.63.4 – Example
.NOSHOW ; Turn off listing file display. Counter < 0.
.
.
.
.SHOW ; Turn on listing file display. Counter = 0.
; Value of .SHOW options are used.
.
.
.
.SHOW ; Counter > 0. Listing file display is
; on for all options regardless of setting.
.
.
.
18.64 – .SIGNED BYTE
Signed byte storage directive
Format
.SIGNED_BYTE expression-list
18.64.1 – Parameters
expression-list
An expression or list of expressions separated by commas. Each
expression specifies a value to be stored. The value must be in
the range of -128 through +127.
18.64.2 – Description
.SIGNED_BYTE generates successive bytes of binary data in the
object module and performs signed range checking. Apart from
the range check, .SIGNED_BYTE is equivalent to .BYTE for storage
allocation.
18.64.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
18.64.4 – Example
.PSECTA,NOEXE
.SIGNED_BYTE LABEL1-LABEL2 ; Data must fit
.SIGNED_BYTE -126 ; in a byte
18.65 – .SIGNED WORD
Signed word storage directive
Format
.SIGNED_WORD expression-list
18.65.1 – Parameter
expression-list
An expression or list of expressions separated by commas. Each
expression specifies a value to be stored. The value must be in
the range of -32,768 through +32,767.
18.65.2 – Description
.SIGNED_WORD generates successive words of binary data in the
object module and performs signed range checking. Apart from
the range check, .SIGNED_WORD is equivalent to .WORD in terms of
storage allocation.
18.65.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a word (16-bit) boundary
before allocating storage.
18.65.4 – Example
.PSECT $DATA,NOEXE
.SIGNED_WORD -32766;
.SIGNED_WORD 32769 ;causes assembly error
18.66 – .SUBTITLE
Listing subtitle directive
Format
.SUBTITLE quoted-literal
.SBTTL quoted-literal
18.66.1 – Parameter
quoted-literal
An ASCII string enclosed in quotes from 1 to 31 characters long;
excess characters are truncated.
18.66.2 – Description
.SUBTITLE causes the assembler to print the line of text as
the subtitle on the second line of each assembly listing page.
This subtitle text is printed on each page until altered by a
subsequent .SUBTITLE directive in the program.
18.66.3 – Notes
o The alternate form of .SUBTITLE is .SBTTL.
o This directive also accepts VAX MACRO syntax. See the
VAX MACRO and Instruction Set Reference Manual for details.
18.66.4 – Example
.SUBTITLE "Terminal Display Routines"
18.67 – .T FLOATING
Double-precision IEEE floating-point arithmetic directive
Format
.T_FLOATING floating-point-number-list
18.67.1 – Parameter
floating-point-number-list
A list of IEEE double-precision floating-point constants
separated by commas.
18.67.2 – Description
.T_FLOATING evaluates the specified floating-point constants and
stores the results in the object module. .T_FLOATING generates
64-bit, double-precision, floating-point data (1 bit of sign, 11
bits of exponent, and 52 bits of fractional significance). See
the description of .S_FLOATING for information on storing single-
precision floating-point IEEE numbers and the descriptions of .D_
FLOATING, .F_FLOATING, and .G_FLOATING for descriptions of other
floating-point numbers.
18.67.3 – Notes
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a quadword (64-bit) boundary
before allocating storage.
18.67.4 – Example
.T_FLOATING 4.5036,6.034
18.68 – .TITLE
Listing title directive
Format
.TITLE module-name ["listing-title"]
18.68.1 – Parameters
module-name
Either a quoted literal or an identifier that specifies the
module's title.
"listing-title"
Optional quoted literal that specifies a title to appear within
the first line of each listing output file.
18.68.2 – Description
.TITLE assigns a name to the object module.
18.68.3 – Notes
o The module name specified with .TITLE bears no relationship
to the file specification of the object module, as specified
in the MACRO-64 command line. The object module name appears
in the linker load map and is also the module name that the
debugger and librarian recognize.
o If .TITLE is not specified, MACRO-64 assigns the default
name (.MAIN.) to the object module. If more than one .TITLE
directive is specified in the source program, the last .TITLE
directive encountered establishes the name for the entire
object module.
o This directive also accepts VAX MACRO syntax. See the
VAX MACRO and Instruction Set Reference Manual for details.
18.68.4 – Example
.TITLE "MAIN" "Main Entry Point"
18.69 – .UNDEFINE REG
Undefine register symbol directive
Format
.UNDEFINE_REG regsym
18.69.1 – Parameter
regsym
A currently defined floating-point or integer register symbol.
18.69.2 – Description
The register symbol that you specify as the argument to the
.UNDEFINED_REG directive is no longer a register symbol. Starting
with the statement that follows the .UNDEFINE_REG directive, you
can use the symbol as a MACRO-64 identifier.
18.69.3 – Notes
o If you specify a MACRO-64 identifier that is not currently
defined as a register symbol, the .UNDEFINE_REG directive has
no effect.
18.69.4 – Example
.DEFINE_IREG X1 R5 ; X1 is integer register 5
.UNDEFINE_REG X1 ; X1 is an identifier again
.DEFINE_IREG X1 7 ; X1 is integer register 7 -
no
; redefinition and no warning
$ROUTINE F0 ; Error: F0 is a register and
; cannot be used as an
; identifier
.UNDEFINE_REG F0 ; F0 is no longer a register
$ROUTINE F0 ; Ok now
18.70 – .WARN
Warning directive
Format
.WARN quoted-literal
18.70.1 – Parameter
quoted-literal
The string of characters enclosed in quotes are displayed during
assembly.
18.70.2 – Description
.WARN causes the assembler to display a warning message on the
terminal or in the batch log file, and in the listing file (if
there is one).
18.70.3 – Notes
o .PRINT, .WARN, and .ERROR are directives that display
messages. You can use them to display information indicating
an unexpected or important assembly condition.
o This directive also accepts VAX MACRO syntax. See the
VAX MACRO and Instruction Set Reference Manual for details.
18.70.4 – Example
.WARN "Illegal parameter value; 0 assumed"
^
%MACRO64-W-
GENWARN, Generated WARNING: Illegal parameter value; 0 assumed
at line number 3 in file DISK$:[TEST]WARN.M64;2
18.71 – .WEAK
Weak symbol attribute directive
Format
.WEAK symbol-list
18.71.1 – Parameter
symbol-list
A list of identifiers separated by commas.
18.71.2 – Description
.WEAK specifies symbols that are either defined externally in
another module or defined globally in the current module. .WEAK
suppresses any object library search for the symbol.
When .WEAK specifies a symbol that is not defined in the current
module, the symbol is externally defined. If the linker finds the
symbol's definition in another module, it uses that definition.
If the linker does not find an external definition, the symbol
has a value of 0 and the linker does not report an error. The
linker does not search a library for the symbol, but if a module
brought in from a library for another reason contains the symbol
definition, the linker uses it.
When .WEAK specifies a symbol that is defined in the current
module, the symbol is considered to be globally defined. However,
if this module is inserted in an object library, this symbol
is not inserted in the library's symbol table. Consequently,
searching the library at link time to resolve this symbol does
not cause the module to be included.
18.71.3 – Example
.WEAK A,B,C
A:: .WORD 5 ; A and B are weak global definitions
B:: .QUAD 6
.ADDRESS C ; C is a weak external reference
18.72 – .WORD
Word storage directive
Format
.WORD expression-list
18.72.1 – Parameter
expression-list
One or more expressions separated by commas.
18.72.2 – Description
.WORD generates successive words (2 bytes) of data in the object
module.
18.72.3 – Notes
o The expression is first evaluated as a quadword and then
truncated to a word. The value of the expression should be
in the range of -32,768 to +32,767 for signed data or 0 to
65,535 for unsigned data. The assembler displays an error if
the high-order 6 bytes of the quadword expression have a value
other than zero or ^XFFFFFFFFFFFF.
o The assembler truncates on the left of an integer or external
value.
o Addresses are not allowed with .WORD.
o You can only use this directive within data or mixed psects
(psects that have either the NOEXE or MIX attributes).
o If automatic data alignment is enabled, this directive aligns
the current location counter to a word (16-bit) boundary
before allocating storage.
18.72.4 – Example
.WORD 5,6,7
19 – Supplied Library Macros
The MACRO-64 assembler provides a library of macros that help you
to program in conformance with the OpenVMS Calling Standard. This
library also allows you to define your own opcodes and packed
decimal data. The library, called MACRO64.MLB, is installed on
your system with the MACRO-64 assembler.
The MACRO-64 assembler automatically adds the MACRO64.MLB library
to the library list before it begins processing your source
program. Consequently, you do not need to add it manually using
the .LIBRARY directive.
The following macros are supplied by the MACRO-64 Assembler:
$BEGIN_EPILOGUE
$CALL
$CODE_SECTION
$DATA_SECTION
$END_EPILOGUE
$END_PROLOGUE
$END_ROUTINE
$LINKAGE_PAIR
$LINKAGE_SECTION
$OPDEF
.PACKED
$PROCEDURE_DESCRIPTOR
$RESET_LP_LIST
$RETURN
$ROUTINE
19.1 – Routines and Lexical Scope
The calling-standard macros use the concept of a single, current,
active routine. A routine is a programming entity that is
associated with a procedure descriptor that may be called, or
is a main routine specified as the transfer address of a linked
image.
Only one routine can be active or current at any given time
during assembly. If more than one routine is defined in a single
assembler source file, all items associated with the current
routine, that is, within the lexical scope of the routine, must
be completed before making a different routine current. The
lexical scope of one routine cannot overlap the lexical scope
of another routine.
A routine becomes current or comes into scope by invoking the
$ROUTINE macro with the appropriate arguments. $ROUTINE marks the
beginning of the lexical scope of a routine. The complementary
macro, $END_ROUTINE, marks the end of the current routine's
lexical scope.
19.1.1 – Routines and Program Sections
Routines have three types of associated program sections:
o Code section-Contains the executable instructions of the
routine. This section is typically read-only and executable.
o Data section-Contains data accessed by a routine. Typically,
this is where variable data is stored. This section is
typically nonexecutable, readable, and writeable.
o Linkage section-Contains a routine's procedure descriptor and
the necessary linkage information for calling other routines,
and for linkage to data not in the linkage section, if any.
Also, constant data may be placed here. Typically, this
section is read-only and not executable.
The linkage section is considered a type of data section with
the following function:
- Provides linkage information for calls made from a routine
associated with the linkage section.
- Provides linkage information for data outside of the
linkage section.
- Defines the associated routine's procedure descriptor so
that calls can be made to the routine.
- Defines constant or static data.
19.2 – Using Macros to Control Program Sections
The following section explains how to use the MACRO-64 supplied
macros to define and control the various program sections during
assembly.
19.2.1 – Defining Program Sections
Each of the three program section types can be referenced by a
corresponding macro. The following three macros are used to refer
to and define these three psects associated within a routine:
o $CODE_SECTION-makes the routine's code psect current.
o $DATA_SECTION-makes the routine's data psect current.
o $LINKAGE_SECTION-makes the routine's linkage psect current.
To switch to one of the current routine's sections, you invoke
the corresponding macro. For example, after invoking $ROUTINE,
to place instructions into the current routine's code psect,
you invoke the $CODE_SECTION macro. This makes the code psect
associated with the current routine the current psect. Similarly,
invoking $LINKAGE_SECTION makes the linkage psect associated with
the current routine the current psect.
You can also control the psect name and attributes for each of
the program sections by defining arguments to the $ROUTINE macro.
19.2.2 – Using Macro Defined Symbols
When you use any of the supplied macros described in this
chapter, with the exception of $OPDEF, the following register
symbols are defined for you:
.DEFINE_IREG $IA0 R16 ; Integer argument 0
.DEFINE_IREG $IA1 R17 ; Integer argument 1
.DEFINE_IREG $IA2 R18 ; Integer argument 2
.DEFINE_IREG $IA3 R19 ; Integer argument 3
.DEFINE_IREG $IA4 R20 ; Integer argument 4
.DEFINE_IREG $IA5 R21 ; Integer argument 5
.DEFINE_FREG $FA0 F16 ; Floating-point argument 0
.DEFINE_FREG $FA1 F17 ; Floating-point argument 1
.DEFINE_FREG $FA2 F18 ; Floating-point argument 2
.DEFINE_FREG $FA3 F19 ; Floating-point argument 3
.DEFINE_FREG $FA4 F20 ; Floating-point argument 4
.DEFINE_FREG $FA5 F21 ; Floating-point argument 5
.DEFINE_IREG $AI R25 ; Argument-information register
.DEFINE_IREG $RA R26 ; Return-address register
.DEFINE_IREG $PV R27 ; Procedure-value register
.DEFINE_IREG $FP R29 ; Frame pointer
.DEFINE_IREG $SP R30 ; Stack pointer
NOTE
SP and FP remain predefined by MACRO-64 whether or not
you use the OpenVMS Calling Standard macros. $SP and
$FP are defined by the OpenVMS Calling Standard macros
for consistency with the other register definitions that
correspond to OpenVMS Calling Standard register conventions.
The following symbols are defined by the $ROUTINE macro. These
symbols are useful while programming with the calling-standard
macros to refer to particular data and linkage section items.
o $CS-The address of the beginning of the current routine's code
section.
o $LS-The address of the beginning of the current routine's
linkage section.
o $DS-The address of the beginning of the current routine's data
section.
o $DP-The linkage section address where the $ROUTINE macro
places the .ADDRESS $DS to enable access to the data section
from the linkage section (this variable is optional).
o $SIZE-The size of the fixed-stack area in bytes. $SIZE is
defined using the value specified with the SIZE argument.
o $RSA_OFFSET-The offset within the fixed-stack area to the
register save area. $RSA_OFFSET is defined using the value
specified with the RSA_OFFSET argument.
o $RSA_END-The offset within the fixed-stack area to the first
byte beyond the end of the register save area.
For more information, see the description for the $ROUTINE macro
in this chapter.
The $CALL macro also defines the $STACK_ARG_SIZE symbol. This
symbol specifies the number of bytes used to store arguments
on the stack. This value is useful after calling a routine that
returns a value on the stack. In this case, $CALL cannot remove
the arguments from the stack because you must first retrieve the
returned value from the stack. Subsequently, you can remove the
arguments from the stack using the $STACK_ARG_SIZE symbol. For
more information, see the description of $CALL in this chapter.
19.2.3 – Defining Procedure Type
The OpenVMS Calling Standard defines four types of routines;
stack, register, null, and bound.
You can define the routine type by using the KIND keyword
argument with $ROUTINE or $PROCEDURE_DESCRIPTOR macros. The
validity and values of other $ROUTINE and $PROCEDURE_DESCRIPTOR
macro parameters are determined by the type of routine being
declared. For example, a null procedure type has no stack size;
therefore, the SIZE parameter is invalid and cannot be specified
for a null procedure type. When using the KIND keyword with the
$ROUTINE or $PROCEDURE_DESCRIPTOR macros, note the following
exceptions:
o The $SIZE symbol defined by $ROUTINE is only valid for stack
and register routines.
o The $RSA_OFFSET symbol defined by $ROUTINE is only valid for a
stack routine.
19.2.4 – Using Macros in Prologue Sections
With stack and register routines, $ROUTINE generates a standard
prologue sequence if you specify the STANDARD_PROLOGUE=TRUE
keyword argument. STANDARD_PROLOGUE=TRUE is the default for
register and stack routines.
Alternatively, you can code your own prologue sequence by
specifying the STANDARD_PROLOGUE argument as FALSE and using the
$END_PROLOGUE macro to mark the end of your prologue sequence. In
this case, you may wish to use the $SIZE and $RSA_OFFSET symbols
to symbolically specify the fixed-stack size and register save
area offset, respectively.
For more information on the prologue sequence of instructions
that must occur at the beginning of all stack and register
routines, see the OpenVMS Calling Standard.
19.2.5 – Using Macros in Epilogue Sections
With stack and register routines, you can use the $RETURN
macro to generate an epilogue sequence. Alternatively, you
can code your own epilogue sequence using the $BEGIN_EPILOGUE
and $END_EPILOGUE macros to mark the beginning and end of your
epilogue sequences.
The OpenVMS Calling Standard also describes the epilogue sequence
of instructions that must be executed every time a stack or
register routine returns to its caller.
19.3 – Programming Examples Using Supplied Macros
Examples Program Using Supplied Macros and Program Using $CALL
show how to use the calling-standard macros to define a routine,
switch control between psects, generate an epilogue sequence, and
end the routine.
Example 3 Program Using Supplied Macros
$ROUTINE MAIN, KIND=STACK, - ; Stack routine kind 1
SAVED_REGS=<FP>, - ; Saves FP 2
SIZE=48 ; Stack size is 48 3
$LINKAGE_SECTION ; Switch to the linkage psect. 4
X: .long 6 ; X is a constant
FP1_ADDR: ; FP1_ADDR -> FP1
.address FP1
$DATA_SECTION ; Switch to the data section 5
A:: .blkw 5 ; $DS points here
B:: .blkw
$CODE_SECTION ; Switch to the code section 6
; ($CS points here)
.
.
.
$RETURN ; Perform epilogue and return 7
$END_ROUTINE MAIN ; Mark the end of the routine 8
1 $ROUTINE defines the routine MAIN. The routine type is defined
as a stack routine using the KIND=STACK keyword argument.
2 The keyword argument SAVED_REGS=<FP> adds the frame pointer
register to the list of registers saved on the stack by the
prologue code. The SAVED_REGS keyword is valid only for stack
procedures. If you do not specify the FP register (R29) with
this argument, it is assumed.
3 The keyword argument SIZE=48 defines the stack area in bytes.
This argument is valid only for register and stack routines.
If you do not specify a stack size for a stack or register
routine, $ROUTINE computes the minimum stack size required to
accommodate the other arguments you specify or leave as the
default.
4 The $LINKAGE_SECTION macro switches to the linkage section.
You can use the $LS symbol created by the $ROUTINE macro
to point to the address of the current routine's linkage
section. $ROUTINE creates the procedure descriptor and leaves
the current location counter within the linkage section just
beyond the procedure descriptor.
5 The $DATA_SECTION macro switches to the data section. You can
use the $DS symbol created by the $ROUTINE macro to point to
the address of the current routine's data section.
6 The $CODE_SECTION macro switches to the code section. The $CS
symbol created by the $ROUTINE macro is used to point to the
address of the current routine's code section.
7 The $RETURN macro generates a standard epilogue instruction
sequence. You can use this macro only with stack or register
routine defined with the $ROUTINE macro.
8 The $END_ROUTINE macro marks the end of the routine.
19.4 – Using the $CALL Macro
$CALL calls local or external routines previously defined by the
$ROUTINE macro or defined in another language.
To call a routine using standard linkage, use the $CALL macro.
You invoke this macro from within the routine's code section.
$CALL performs the following actions:
o Searches a list of linkage pairs referenced in previous
invocations of the $CALL and $LINKAGE_PAIR macros within
the calling routine. If a linkage pair is already found to
exist on the list, $CALL uses the linkage pair stored from the
previous invocation. Otherwise, $CALL stores the linkage pair
of the called routine in the caller's linkage section and adds
the linkage pair to the caller's list.
o Allocates stack space for arguments, if necessary.
o Loads arguments specified with the ARGS argument into argument
registers and onto the stack, as appropriate.
o Sets the arguments information register, R25, according to the
arguments specified with ARGS argument.
o Generates the following instruction sequence to perform
the actual call based on the location of the linkage pair
generated from above, and the value of Rls, linkage register,
which is assumed to point to the base of the linkage section:
LDQ R26, code_addr_offset(Rls) ; load code address
LDQ R27, proc_desc_addr_offset(Rls) ; load procedure
; descriptor address
;
JSR R26, R26 ; Jump to the routine
; saving the return
; address in R26
o Frees argument stack space, if any, and if the called routine
does not return a value on the stack.
Like $ROUTINE, the $CALL macro invokes other macros to perform
the previous tasks.
If you do not specify the Rls argument in your invocation of
$CALL, $CALL assumes that you have used the .BASE directive
to define a register that points to the base address of your
linkage section. That is, it assumes that you have included a
statement similar to the following:
.BASE R27, $LS
This source statement defines the base address of the linkage
section to be R27, and to be associated with the macro symbol
$LS. This source statement should be placed in your source
code before the $CALL macro call.
19.4.1 – Using $CALL in Source Code
This example uses the same source code from the previous example,
except it uses the $CALL macro to show how to call a local and
external routine.
Example 4 Program Using $CALL
.
.
.
$CODE_SECTION ; Switch to the code section
; ($CS points here)
.
.
.
MOV R27,R2 1
.base R2, $LS 2
.
.
.
$CALL SUB1 ; Call external routine SUB1 3
$CALL SUB2, LOCAL=TRUE ; Call local routine SUB2 4
.
.
.
$RETURN ; Perform epilogue and return
$END_ROUTINE MAIN ; Mark the end of the routine
1 The $LS symbol is defined to be the address of the procedure
that is defined within the linkage section. The calling
routine places the address of the procedure descriptor in
R27 before making the call. This guarantees that the address
associated with the symbol $LS is stored in R27 upon routine
entry. Since the information in R27 is erased during a
standard call, a copy is preserved in register R2.
2 Register R2 now contains the address of our procedure
descriptor, which is the base address of our linkage section.
Since $LS is defined to point to the base address of the
linkage section, the assembler computes the offsets within
the linkage section using the .BASE directive.
3 The $CALL macro calls the external routine SUB1.
4 The $CALL macro calls the local routine SUB2. This call uses
the LOCAL=TRUE keyword argument to indicate that routine SUB2
is defined within the module.
19.5 – Programming Considerations
This section discusses some programming considerations you need
to be aware of when using the calling-standard macros.
19.5.1 – Making Multiple Calls From the Same Routine
The $CALL macro generates the following instruction sequence:
LDQ R26, code_address_offset(Rls) ; load code address
LDQ R27, procedure_descriptor_address_offset(Rls) ; load procedure
; descriptor
; address
JSR R26, R26 ;
The contents of R26 and R27 are erased as a result of using the
$CALL macro. This is important since Rls in the previous sequence
is typically R27. Thus, if you require subsequent access to your
linkage section, such as when making subsequent calls, you need
to make a working copy of R27 to use after the first call.
Note that $CALL also overwrites the values in the argument
registers, and the scratch registers specified or the default
set by the SCRATCH_REGS argument, when you pass arguments to the
called routine.
19.5.2 – Nonstandard Linkage
Under certain circumstances, there may be advantages in using a
nonstandard routine linkage.
19.5.3 – Routine Restrictions
Different routine types have different capabilities and
restrictions. For example, only a stack routine that specifies
BASE_REG_IS_FP=TRUE can make standard calls.
19.5.4 – Syntax Rules
You can use either positional or keyword argument association
or a combination of the two with these macros. For positional
association, the order of formal arguments is shown with
the format of each macro. The following syntax rules apply
when invoking the assembler using the command-line qualifier
/NAMES=AS_IS:
o When specifying macro names, you must use all uppercase or all
lowercase characters. You cannot mix uppercase and lowercase
characters.
o When specifying keyword arguments, you must use the same
alphabetic case as the macro name it is associated with. If
you use lowercase characters with the macro name, you must
use lowercase characters with the keyword argument. If you
use uppercase characters with the macro name, you must use
uppercase characters with the keyword argument.
19.6 – $BEGIN EPILOGUE
Marks the beginning of an epilogue instruction sequence.
Format
$BEGIN_EPILOGUE
19.6.1 – Description
$BEGIN_EPILOGUE marks the beginning of an epilogue instruction
sequence that you code within a stack or register routine defined
with the $ROUTINE macro.
At each point where a stack or register routine returns to
its caller, the routine must perform a sequence of operations
to restore any saved registers and to perform stack frame
management. This sequence is called the epilogue and is described
in detail in the OpenVMS Calling Standard.
You can use the $RETURN macro to generate a standard epilogue
instruction sequence for you, or you can code your own sequence.
If you code your own epilogue sequence, you must mark the
beginning and end of the epilogue sequence with the $BEGIN_
EPILOGUE and $END_EPILOGUE macros.
19.6.2 – Notes
o You must not use $BEGIN_EPILOGUE for an epilogue instruction
sequence generated by $RETURN. $RETURN automatically invokes
$BEGIN_EPILOGUE and $END_EPILOGUE.
19.6.3 – Example
$ROUTINE MUMBLE, KIND=REGISTER, SAVE_FP=R1
:
:
:
$BEGIN_EPILOGUE
MOV R1,FP ; Restore caller's frame
RET (R26) ; Return to caller
$END_EPILOGUE
:
:
:
$END_ROUTINE MUMBLE
19.7 – $CALL
Issues a call to another routine.
Format
$CALL NAME=routine-being-called -
[Rls=linkage-section-register] -
[LS=linkage-section-address] -
[LOCAL=boolean] -
[ARGS=argument-list] -
[SET_ARG_INFO=boolean-value] -
[STACK_RETURN_VALUE=boolean-value] -
[SCRATCH_REGS=scratch_reg-list] -
[TIE=boolean-value] -
[FUNC_RETURN=
{I64,D64,I32,U32,FF,FD,FG,FS,FT,FDC,FGC,FSC,FTC}]
-
[USES_VAX_ARGLIST=boolean-value] -
[SIGNATURE_BLOCK=signature_address] -
[NONSTANDARD=boolean-value] -
19.7.1 – Parameters
NAME
The name of the routine to call. This argument is required.
Rls
Linkage section register to use when generating the LDQ, LDQ, JSR
instruction sequence. This argument is optional.
If Rls is omitted, $CALL assumes that you entered a .BASE
directive before invoking $CALL that establishes the value of a
base register pointing into the linkage section. If you omit the
Rls argument and you do not enter such a .BASE directive before
invoking $CALL, the assembler issues the following error message
during the $CALL macro expansion:
"Argument 2 invalid" The assembler failed to find a
base register specified with a previous .BASE directive
to form a register expression of the form offset(Rn)"
LS
LS is the address of the linkage section. If you use $CALL within
a routine defined by the $ROUTINE macro, the LS argument defaults
to the $LS symbol defined by $ROUTINE. If you use $CALL outside
of a routine defined by the $ROUTINE macro, there are two ways
that you can indicate the location of the linkage section to
$CALL. First, you can specify the LS argument to $CALL as a
relocatable address expression that indicates the base of the
linkage section. In this case you must also specify the Rls
argument. Second, you can specify both the linkage-section base
register and the linkage-section address in a .BASE directive
before invoking $CALL. In this case, you must omit both the Rls
and LS arguments to $CALL.
Digital recommends that you omit this argument if you use $CALL
within a routine defined by the $ROUTINE macro.
LOCAL
A Boolean value (TRUE or FALSE) that specifies whether the
routine to be called is local to the module or globally visible.
By default, $CALL generates a call to a globally visible routine.
To generate a call to a routine that is not globally visible, you
must specify LOCAL=TRUE.
ARGS
An optional list of arguments to pass to the called routine.
Enclose the argument list within angle brackets (<>) and
separate the arguments with commas (,). You can use the
following qualifiers with each argument you specify with the
ARGS argument. These qualifiers are described in the following
table.
Each argument is an address expression (which may include a
register) followed by a qualifier. The table also contains
the argument type, the instruction used to load the argument
into a register, the instruction used to store the argument on
the stack, and the encodings used in the Argument Information
Register (R25) in the call signature block when you specify
TIE=TRUE. See the OpenVMS Calling Standard for more information
on these encodings. Note that arguments are only stored on
the stack if there are more than six arguments provided to the
routine.
ARGS Arguments
_________________________________________________________________________
Argument
Argument LOAD STORE AI Reg Arg Mem Arg
Qualifier Type Instruction Instruction Encoding Signature Signature
_________________________________________________________________________
19.7.1.1 /A Address LDA STQ I64 I32 I32
19.7.1.2 /D D-floating LDG STG FD FD Q
19.7.1.3 /F F-floating LDF STF FF FF I32
19.7.1.4 /G G-floating LDG STG FG FG Q
19.7.1.5 /L Longword LDL STQ I64 I32 I32
19.7.1.6 /Q Quadword LDQ STQ I64 Q Q
19.7.1.7 /S S-floating LDS STS FS FS I32
19.7.1.8 /T T-floating LDT STT FT FT Q
19.7.1.9 /UL(1) Unsigned LDL STQ I64 U32 I32
Longword /ZAP
#^xF0
_______________________________________________________________________
(1)--Unsigned 32-bit integers are normally passed using the /L argument
qualifier. Therefore, Digital does not recommend that you use the /UL
argument qualifier.
_______________________________________________________________________
SET_ARG_INFO
An optional argument to indicate whether $CALL should
set the Argument Information (AI) register (R25) with
the appropriate argument information or not. By default,
or if you specify SET_ARG_INFO=TRUE, $CALL stores the
appropriate argument information in R25. If you specify
SET_ARG_INFO=FALSE, $CALL does not affect R25.
If you want to conform to the OpenVMS Calling Standard, you
must store the appropriate information in R25 yourself before
invoking $CALL. If you do not need to conform to the OpenVMS
Calling Standard, and if the called routine does not need
argument information in R25, you can specify SET_ARG_INFO=FALSE
and make no change in R25. By making no change in R25, you
avoid the overhead involved when either you or $CALL load
argument information into R25 at the expense of calling standard
conformance.
STACK_RETURN_VALUE
An optional argument to indicate that the called routine returns
a value on the stack. By default, $CALL assumes that the called
routine does not return a value on the stack. In this case, $CALL
removes any arguments passed to the called routine from the stack
when the called routine returns.
If the called routine returns a value on the stack, the returned
value is placed at a lower address than the arguments on the
stack. In this case, you must specify STACK_RETURN_VALUE=TRUE
to prevent $CALL from removing the arguments to the called
routine from the stack and erasing the value returned by the
called routine. You must retrieve the return value and remove it
from the stack. Then you can remove the arguments to the called
routine using the $STACK_ARG_SIZE symbol defined by $CALL.
SCRATCH_REGS
An optional list of scratch registers for $CALL to use when
processing arguments passed to the called routine with the ARGS
argument. If you pass more than six arguments to the called
routine, $CALL may need to use scratch registers to process the
call.
By default, $CALL uses R0, R1, F0, and F1. You can cause $CALL to
use different scratch registers with the SCRATCH_REGS argument.
If you are passing integer arguments, you should specify at
least one integer register. If you are passing floating-point
arguments, you should specify at least one floating-point
register.
$CALL can process arguments to the called routine more
efficiently if you specify two or more scratch registers of the
type or types appropriate to the arguments you are passsing.
TIE
A Boolean value (TRUE or FALSE) that specifies whether $CALL
should generate a call sequence that is compatible with both
native routines and the Translated Image Environment (TIE). By
default, $CALL generates a faster call sequence that is only
compatible with native routines. If you specify TIE=TRUE, $CALL
generates a call sequence that works with both native routines
and translated routines. If you are calling a VAX routine in a
shareable image that has been translated with the DECmigrate
image translator, specify TIE=TRUE. If you are calling a native
routine, Digital recommends you default the TIE argument or
specify TIE=FALSE. While $CALL generates a call sequence that
is compatible with native routines when you specify TIE=TRUE,
that call sequence is slower than when you specify or default
TIE=FALSE.
FUNC_RETURN
An optional argument used to indicate the type of function return
when you also specify TIE=TRUE. This argument is ignored unless
you also specify TIE=TRUE. Specify one of I64, D64, I32, U32,
FF, FD, FG, FS, FT, FFC, FDC, FGC, FSC, or FTC. These values
correspond to the RASE$K_FR_* signature encodings described
in Table 3-7 in the OpenVMS Calling Standard. If you specify
TIE=TRUE and do not specify a function return type with FUNC_
RETURN, the default function return type is I64.
NOTE
Specification of the FUNC_RETURN argument does not in itself
cause $ROUTINE to generate a procedure signature block.
However, if you specify either or both the ARGLIST or USES_
VAX_ARGLIST arguments, any value you specify with the FUNC_
RETURN argument is recorded in both the procedure descriptor
and the procedure signature block.
USES_VAX_ARGLIST
An optional argument to indicate whether the called routine uses
a VAX argument list. This argument is ignored unless you also
specify TIE=TRUE. By default, $CALL assumes the called routine
does not use a VAX argument list. Specify USES_VAX_ARGLIST=TRUE
to indicate that the called routine uses a VAX argument list.
SIGNATURE_BLOCK
An optional argument that you can use to supply the address of
the call signature block. This argument is ignored unless you
also specify TIE=TRUE. Note that you cannot specify a SIGNATURE_
BLOCK argument in combination with either of the FUNC_RETURN
or USES_VAX_ARGLIST arguments. By default, $CALL generates a
call signature block for you when you specify TIE=TRUE, and you
can in part control the contents of that signature block with
the FUNC_RETURN and USES_VAX_ARGLIST arguments. If you wish to
define your own call signature block, do not specify either of
the FUNC_RETURN or USES_VAX_ARGLIST arguments and supply the
address of your call signature block with the SIGNATURE_BLOCK
argument.
NONSTANDARD
A Boolean value (TRUE or FALSE) that specifies whether $CALL
should suppress warning and informational messages concerning
nonstandard usage. By default, $CALL issues warning and
informational messages to indicate you are using $CALL in a
way that violates the OpenVMS Calling Standard or in a way
that requires special programming considerations. Specify
NONSTANDARD=TRUE if you wish to suppress these messages.
19.7.2 – Description
$CALL issues a call to another routine and performs the following
actions:
1. Searches a list of linkage pairs referenced in previous
invocations of the $CALL and $LINKAGE_PAIR macros. If a
linkage pair is already in the list, $CALL uses the linkage
pair from the previous invocation. Otherwise, $CALL stores
the linkage pair of the called routine in the caller's linkage
section and adds the linkage pair to the caller's list. If you
use $CALL within a routine defined with the $ROUTINE macro,
$CALL and $LINKAGE_PAIR reset the list of linkage pairs for
each routine.
2. Allocates stack space for arguments if necessary.
3. Generates instructions to load the arguments to the called
routine.
4. Sets the value in the argument information register, R25.
5. Generates the following instruction sequence to perform
the actual call based on the location of the linkage pair
generated from step 1 and the address specified or defaulted
with the LS argument. The register specified with the Rls
argument is assumed to point to the base of the linkage
section as shown in the following example:
LDQ R26, code_address_offset(Rls) ; load code address
LDQ R27, procedure_descriptor_address_offset(Rls) ; load
; procedure
; descriptor
; address
JSR R26, R26
6. Frees argument stack space, if any, and if the called routine
does not return a value on the stack.
19.7.3 – Examples
Example 1
$CALL SUB1, Rls=R13, LS=MY_LINKAGE_SECTION
.BASE R13, MY_LINKAGE_SECTION
$CALL SUB2
$ROUTINE SUB3, KIND=STACK, SAVED_REGS=<R2,FP>
$LINKAGE_SECTION
.QUAD 1
XX:
$CODE_SECTION
MOV R27, R2
$CALL SUB4, R2
.BASE R2, $LS
$CALL SUB5
$CALL SUB6, -
ARGS=<XX/A, R0/Q>, -
SCRATCH_REGS=<R22,R23>
$CALL SUB7, -
ARGS=<1/A,2/A,3/A>
$RETURN
$END_ROUTINE SUB3
Example 2
$CALL FOO, ARGS=<A,B,C,D,E,F,G,H>, STACK_RETURN_VALUE=TRUE
; Fetch octaword return value from stack
LDQ R4, 0(SP) ; low quadword
LDQ R5, 8(SP) ; high quadword
LDA SP, $STACK_ARG_SIZE+16(SP) ; RESET STACK
19.8 – $CODE SECTION
Switches control to the current routine's code section psect.
Format
$CODE_SECTION
19.8.1 – Description
$CODE_SECTION switches control to the current routine's code
section psect.
19.8.2 – Example
$CODE_SECTION
19.9 – $DATA SECTION
Switches control to the current routine's data section psect.
Format
$DATA_SECTION
19.9.1 – Description
$DATA_SECTION switches control to the current routine's data
section psect.
19.9.2 – Example
$DATA_SECTION
19.10 – $END EPILOGUE
Marks the end of an epilogue instruction sequence.
Format
$END_EPILOGUE
19.10.1 – Description
You can use the $END_EPILOGUE macro to mark the end of an
epilogue instruction sequence that you code yourself within
a stack or register routine defined with the $ROUTINE macro.
At each point where a STACK or REGISTER routine returns to
its caller, the routine must perform a sequence of operations
to restore any saved registers and to perform stack-frame
management. This sequence is called the epilogue and is described
in detail in the OpenVMS Calling Standard.
You can use the $RETURN macro to generate a standard epilogue
instruction sequence for you. Alternatively, you can code your
own sequence. If you code your own epilogue sequence, you must
mark the beginning and end of the epilogue sequence with the
$BEGIN_EPILOGUE and $END_EPILOGUE macros, respectively.
Note that you must not use $END_EPILOGUE for an epilogue
instruction sequence generated by $RETURN. $RETURN invokes
$BEGIN_EPILOGUE and $END_EPILOGUE for you.
You may omit the invocation of $END_EPILOGUE if your epilogue
sequence occurs at the end of the routine. The $END_ROUTINE macro
invokes $END_EPILOGUE for you if you invoke the $BEGIN_EPILOGUE
macro without a matching invocation of the $END_EPILOGUE macro.
You must invoke $END_EPILOGUE with epilogue sequences that occur
in the middle of your routine.
19.10.2 – Example
$ROUTINE MUMBLE, KIND=REGISTER, SAVE_FP=R1
:
:
:
$BEGIN_EPILOGUE
MOV R1,FP ; Restore caller's frame
RET (R26) ; Return to caller
$END_EPILOGUE
:
:
:
$END_ROUTINE MUMBLE
19.11 – $END PROLOGUE
Marks the end of a prologue instruction sequence.
Format
$END_PROLOGUE
19.11.1 – Description
$END_PROLOGUE marks the end of a routine prologue instruction
sequence that you code yourself. The prologue instruction
sequence begins with the first instruction of the routine. There
can only be one prologue instruction sequence in a routine. The
prologue is described in detail in the OpenVMS Calling Standard.
You invoke $END_PROLOGUE after the last instruction in the
routine prologue code. The last instruction in the routine
prologue is the one that updates FP (R29, the frame pointer)
and makes the frame become current. You must use this macro
when the routine type is stack or register and you specify
STANDARD_PROLOGUE=FALSE to the $ROUTINE macro.
19.11.2 – Notes
o Do not use this macro when the $ROUTINE macro generates a
standard prologue or when the routine type is null or bound.
For example, a standard prologue is generated for you when you
specify or leave the default of $ROUTINE's STANDARD_PROLOGUE
argument to TRUE.
19.11.3 – Example
MOV SP, FP
$END_PROLOGUE
19.12 – $END ROUTINE
Marks the end of a routine.
Format
$END_ROUTINE [name=routine-name]
19.12.1 – Parameter
name
The name of the routine that is ended. This argument is optional.
If you specify a name, $END_ROUTINE verifies that the name
matches that which was specified with $ROUTINE to begin the
routine. If the name does not match, $END_ROUTINE issues a
diagnostic message. There is no default. If you omit the name,
$END_ROUTINE does not verify a matching name.
19.12.2 – Description
You must use this macro at the end of a routine that is defined
with the $ROUTINE macro to delimit the end the current routine
and to perform final macro processing of the routine.
19.12.3 – Example
$END_ROUTINE NAME=FOOZLE
19.13 – $LINKAGE PAIR
Locates or defines a linkage pair in the linkage psect.
Format
$LINKAGE_PAIR name=routine-name, local=boolean
19.13.1 – Parameters
name
Name of the linkage pair to define. This argument is required.
local
A Boolean value (TRUE or FALSE) that specifies whether the
routine is defined within the module for not. The default is
to store a linkage pair for a global routine. You must specify
LOCAL=TRUE to store a linkage pair for a routine that is not
globally visible.
19.13.2 – Description
You can invoke this macro to locate or define a linkage pair
in the linkage psect. The linkage pair is added to a list for
later use and retrieval by the $CALL and $LINKAGE_PAIR macros.
Thus, only the first invocation of $LINKAGE_PAIR (or $CALL) for
a given routine to be called results in a linkage pair being
stored. $LINKAGE_PAIR and $CALL use the same list of linkage
pairs. $LINKAGE_PAIR restores the current psect when it is done.
$LINKAGE_PAIR defines the symbol $LP. This symbol value is the
address within the linkage section of the linkage pair for the
specified routine to call.
19.13.3 – Notes
o Because the $CALL macro invokes the $LINKAGE_PAIR macro
for you, you do not need to use $LINKAGE_PAIR when you are
using $CALL. You may wish to use $LINKAGE_PAIR when you are
not using $CALL or when you require a specific ordering or
placement of linkage pairs within the linkage section.
19.13.4 – Example
$LINKAGE_PAIR SUB1 ; define linkage pair in linkage section
LDQ R26, $LP
LDQ R27, $LP+8
JSR R26, R26
19.14 – $LINKAGE SECTION
$LINKAGE_SECTION switches control to the current routine's
linkage section psect.
Format
$LINKAGE_SECTION
19.14.1 – Description
$LINKAGE_SECTION switches control to the current routine's
linkage section psect.
19.14.2 – Example
$LINKAGE_SECTION
19.15 – $OPDEF
Used to define opcodes.
Format
$OPDEF MNEMONIC, FORMAT, ENCODING [,DEFAULTS]
19.15.1 – Parameters
MNEMONIC
MNEMONIC is the mnemonic name by which the instruction is called.
You may optionally specify a qualifier list separated from the
name by a slash (/). A qualifier list is a sequence of one or
more letters or digits with no intervening spaces or separators.
FORMAT
FORMAT is one of the following arguments:
Format Description
MEMORY Standard memory format instructions.
MEMORY_FUNCTION Memory format instructions with a
function code.
JUMP Memory format instructions formatted
like jump instructions.
BRANCH Standard branch format instructions.
OPERATE Standard operate instructions.
FLOATING_OPERATE Standard floating-point operate
instructions.
PAL Standard PALcode instructions.
<CUSTOM=operand_type_list> Custom format.
With the CUSTOM format, you may optionally specify a list of the
types of operands the instruction is to accept. If you specify
a list of operand types, you must enclose the entire FORMAT
argument within angle brackets, and you must specify the operand
types in the order they are to be used with the instruction.
$OPDEF supports the following operand types:
IREGISTER Integer register, such as R5 or SP.
FREGISTER Floating-point register, such as F7.
LITERAL Integer literal, such as #123 or 32767.
LIT_IREG Integer literal, such as #123 or 32767, or integer
register, such as R5 or SP.
INDIRECT Indirect integer register notation such as (R7).
DISPLACEMENT Indirect integer register notation with an integer
literal displacement, such as FOO(R12).
BRANCH_OFFSET Label or address expression, such as L1.
For example:
FORMAT=<CUSTOM=IREGISTER,DISPLACEMENT>
The following example shows the definition of the ADDQ
instruction, which takes either an integer register or literal
as its second argument:
$OPDEF ADDQ, -
FORMAT=<CUSTOM=IREGISTER,LIT_IREG,IREGISTER>, -
ENCODING=<26:31=^x10, -
21:25=%OP1, -
12:20=%OP2, -
5:11=^x20, -
0:4=%OP3>
For a detailed description of instruction formats, see the Alpha
Architecture Reference Manual.
ENCODING
ENCODING is the numeric encoding for the instruction opcode.
The default radix is decimal, as is the case for all assembler
constants. Prefix the value with ^X for hexadecimal. Certain
instruction formats allow multipart encoding:
Format Encoding Description
MEMORY_FUNCTION Specify the base opcode, followed by a dot,
followed by the function code. For example:
ENCODING=^X10.F000
JUMP Specify the base opcode, optionally followed
by a dot, and the hardware-hint bits
optionally followed by a dot and the software-
hint bits. For example:
ENCODING=^X1A.2.1
OPERATE Specify the base opcode, followed by a dot,
followed by the function code. For example:
ENCODING=^X12.3C
FLOATING_OPERATE Specify the base opcode, followed by a dot and
the function code. For example:
ENCODING=^X17.02B
PAL Specify the base opcode, optionally followed
by a dot and the function code. Omit the
function code for a generic PAL instruction
that accepts an integer-expression argument.
For example:
ENCODING=^X0.0080
ENCODING=^X19
CUSTOM Specify a comma-separated list of bit ranges
and values to place in those bit ranges. For
example:
ENCODING = < 26:31=^X14, 21:25=%OP1, -
16:20=%OP2.REG, 0:15=%OP2.DISP >
For CUSTOM format instructions, specify the ENCODING argument as
a comma-separated list of bit ranges and values to place in those
bit ranges. Enclose the list within angle brackets.
Specify a bit range as start:end where start and end are integer
constant expressions. For a 1-bit bit range, start and end are
equal. Bit positions range from 0 to 31. Place an equal sign (=)
after the bit-range specifier followed by the value you wish to
put in the bit range. You can place either a constant integer
expression or an operand into the bit range. Start and end
expressions and integer constant expressions must not reference
any external symbols or symbols not yet defined in the assembly.
$OPDEF evaluates these expressions at the time that it defines
the instruction as opposed to when the defined instruction is
referenced.
Operand names are of the form %OPn, where n is the ordinal number
of the operand as specified from left to right with the FORMAT
argument.
For the IREGISTER, FREGISTER, and INDIRECT operands, $OPDEF
places the 5-bit register number into the bit positions you
specify.
For LITERAL operands, $OPDEF places the literal value of the
operand into the bit positions you specify. Operand literal
values can be up to 32 bits long. The most significant bits
are truncated if the size of the operand literal value exceeds
the bit range you specify. Forward and external references are
allowed.
For LIT_IREG operands, $OPDEF places either a literal value or
a 5-bit register number into the bit positions you specify. If a
literal, the low bit is 1, and the literal value is placed in the
upper bits. If an integer register, the low four bits are 0, and
the high five bits contain the register number.
For DISPLACEMENT operands, $OPDEF defines two parts: a 5-bit
register number and a displacement value that can be up to 32
bits long. The most significant bits are truncated from the
displacement value if the size of the displacement value exceeds
the bit range you specify. You can reference the register number
by placing .REG after the operand name. For example: %OP2.REG.
Similarly, you can reference the displacement value by placing
.DISP after the operand name. For example: %OP2.DISP. Forward
references are allowed. Relocatable expressions are not allowed.
For BRANCH_OFFSET operands, $OPDEF stores the signed longword
offset between the next instruction and the specified address in
the bit positions you specify. The address expression specified
for a BRANCH_OFFSET operand can be a backward or forward
reference to a location within the current psect. It cannot
be an external address or an address in a different psect. The
resulting offset can be up to 32 bits in size. If the size of the
offset exceeds the bit range you specify, the most significant
bits are truncated.
$OPDEF fills any bit positions you leave unspecified with zeros.
DEFAULTS
DEFAULTS is an optional list of operand defaults of the form
<%OPn=value, ...>, where n is the number of the operand to which
the value is to apply as a default. Operand defaults may be
specified in any order. If you specify a default for one or more
operands, you need not specify a default for all operands.
The following example specifies a default of R31 for the first
instruction argument:
$OPDEF RET, FORMAT=<CUSTOM=IREGISTER,INDIRECT>, -
ENCODING=<26:31=^x1A, -
21:25=%OP1, -
16:20:%OP2, -
14;14=^x2,0:13=0>, -
DEFAULTS=<%OP1=R31>
19.15.2 – Description
You can use the $OPDEF macro to define your own opcodes.
$OPDEF defines a macro using an unqualified version of the
mnemonic name you specify. When this macro is invoked with the
instruction qualifiers you specify when you define it with $OPDEF
(if any), it expands to the instruction representation you have
defined with $OPDEF. You can specify the qualifiers in any order
as long as the combination of qualifiers you use is the same.
Other uses of the mnemonic name remain valid provided you do not
use the mnemonic name as a macro name in a .MACRO directive. For
instance, you can use the same mnemonic name in the opcode field
with different or no qualifiers. If the qualifiers (or absence
thereof) do not match those specified in your $OPDEF instruction
definition, the macro defined by $OPDEF processes as though you
had not defined an instruction by that mnemonic name. To do
so, it expands to a single statement. This expansion statement
is identical to the mnemonic-name macro invocation statement,
except it is processed in a context that prevents the mnemonic-
name macro from expanding recursively. Instead, the statement
is processed as a normal, MACRO-64 instruction statement. In
this case, you may notice references to the mnemonic-name macro
expansion in a MACAUXMSG diagnostic message if the instruction
statement contains errors.
For instance, if you define a STQ/P instruction using $OPDEF,
you can still use the STQ instruction without the /P qualifier.
If you do, and your STQ instruction statement contains an error,
the assembler generates a MACAUXMSG message indicating that the
error occurred during the expansion of macro STQ. Aside from
the fact that the STQ instruction is processed in the context of
the expansion of the STQ macro, $OPDEF's definition of the STQ/P
instruction has no effect on your use of the STQ instruction.
19.15.3 – Example
$OPDEF MNEMONIC=BANG, FORMAT=PAL, -
ENCODING=^X0.0099
19.16 – .PACKED
Packed decimal string storage macro.
Format
.PACKED decimal-string[,symbol]
19.16.1 – Parameters
decimal-string
A decimal number from 0 to 31 digits long with an optional sign.
Digits can be in the range 0 to 9.
symbol
An optional symbol that is assigned a value equivalent to the
number of decimal digits in the string. The sign is not counted
as a digit.
19.16.2 – Description
.PACKED generates packed decimal data with two digits per byte.
Packed decimal data is useful in calculations requiring exact
accuracy. It is operated on by the decimal string instructions.
A packed decimal string is a contiguous sequence of bytes in
memory. It is specified by two attributes: the address A of
the first byte and a length L, which is the number of digits in
the string and not the length of the string in bytes. The bytes
of a packed decimal string are divided into two, 4-bit fields
(nibbles). Each nibble except the low nibble (bits 3:0) of the
last (highest-addressed) byte must contain a decimal digit. The
low nibble of the highest-addressed byte must contain a sign. The
representation for the digits and sign is indicated as follows:
Digit
or
Sign Decimal Hexadecimal
0 0 0
1 1 1
2 2 2
3 3 3
4 4 4
5 5 5
6 6 6
7 7 7
8 8 8
9 9 9
+ 10,12,14, or A,C,E, or F
- 15 B or D
11 or 13
The preferred sign representation is 12 for plus (+) and 13 for
minus (-). The length L is the number of digits in the packed
decimal string (not counting the sign); L must be in the range
0 to 31. When the number of digits is odd, the digits and the
sign fit into a string of bytes whose length is defined by the
following equation: L/2(integer part only) + 1. When the number
of digits is even, it is required that an extra 0 appear in the
high nibble (bits 7:4) of the first byte of the string. Again,
the length in bytes of the string is L/2 + 1.
The address A of the string specifies the byte of the string
containing the most-significant digit in its high nibble. Digits
of decreasing significance are assigned to increasing byte
addresses and from high nibble to low nibble within a byte.
Thus, +123 has a length of 3. The packed decimal number -12
has a length of 2.
19.16.3 – Example
.PACKED -12,PACKED_SIZED ; PACKED_SIZE gets value of 2
.PACKED +500
.PACKED 0
.PACKED -0,SUM_SIZE ; SUM_SIZE gets value of 1
19.17 – $PROCEDURE DESCRIPTOR
Defines a procedure descriptor structure at the current psect and
offset.
Format
$PROCEDURE_DESCRIPTOR
19.17.1 – Description
The arguments for the $PROCEDURE_DESCRIPTOR macro are the same as
the $ROUTINE macro, with the following exceptions:
o The ENTRY argument is required.
o There are no CODE_SECTION, LINKAGE_SECTION, DATA_SECTION,
DATA_SECTION_POINTER, or STANDARD_PROLOGUE arguments.
o There is an additional END_PROLOGUE argument. This argument
must be a label that you define at the end of the routine's
prologue sequence. This argument is required for stack and
register procedure types.
19.17.2 – Notes
o Because the $ROUTINE macro invokes the $PROCEDURE_DESCRIPTOR
macro for you, you do not need to use the
$PROCEDURE_DESCRIPTOR macro if you use $ROUTINE. You may wish
to use $PROCEDURE_DESCRIPTOR when you are not using $ROUTINE.
19.17.3 – Example
$PROCEDURE_DESCRIPTOR p1, -
KIND=NULL, -
ENTRY=p1_entry
19.18 – $RESET LP LIST
Clears the list of linkage pairs maintained by the $LINKAGE_PAIR
and $CALL macros.
Format
$RESET_LP_LIST
19.18.1 – Description
The $LINKAGE_PAIR and $CALL macros maintain an assembly-time
list of linkage pairs that the $LINKAGE_PAIR macro has stored in
the linkage section. This list enables $LINKAGE_PAIR and $CALL
to use the same linkage pair for multiple routine calls to the
same routine. You can clear this list of linkage pairs with the
$RESET_LP_LIST macro.
Under normal circumstances, you do not need to clear the linkage-
pair list. Some of the times when you do are as follows:
o When you change the psect assigned to the linkage section.
o If distance from the linkage section of your current routine
falls more than 32K bytes beyond where the linkage pair has
been stored.
19.18.2 – Example
; Define the linkage section psect for routines A & B
$LINK$ = "AB_LINK,NOEXE,OCTA"
$ROUTINE A, KIND=STACK
.BASE R27, $LS
$CALL D ; Linkage pair is stored in A's linkage
; section and put on the assembly-time list
$RETURN
$END_ROUTINE A
$ROUTINE B, KIND=STACK
.BASE R27, $LS
$CALL D ; Linkage pair is found on the list,
; and used from A's linkage section
$RETURN
$END_ROUTINE B
; Define a different linkage section for routine C
$LINK$ = "C_LINK,NOEXE,OCTA"
; Linkage pairs that are on the list are in A & B's linkage
; section, which is not easily accessible by C. Therefore,
; clear the list.
$RESET_LP_LIST
$ROUTINE C, KIND=STACK
.BASE R27, $LS
$CALL D ; Linkage pair is stored in C's linkage
; section and put on the assembly-time list
$RETURN
$END_ROUTINE B
19.19 – $RETURN
Generates a standard epilogue instruction sequence.
Format
$RETURN
19.19.1 – Description
Generates a standard epilogue instruction sequence when used
within a stack or register routine defined with the $ROUTINE
macro. The epilogue sequence generated by $RETURN restores any
registers you specify with the SAVED_REGS argument to $ROUTINE
and performs stack frame management as necessary. You can use
$RETURN whether or not you specify STANDARD_PROLOGUE as TRUE or
accept the default.
You can use $RETURN any number of times within a given stack or
register routine to affect a return to the calling routine.
You must not use the $BEGIN_EPILOGUE or $END_EPILOGUE macros
for an epilogue sequence generated by $RETURN. $RETURN invokes
$BEGIN_EPILOGUE and $END_EPILOGUE for you.
19.19.2 – Example
$ROUTINE FOOZLE, KIND=REGISTER, SAVE_FP=R1
:
:
:
$RETURN
$END_ROUTINE FOOZLE
19.20 – $ROUTINE
Defines the current routine and creates a context for the
routine.
Format
$ROUTINE NAME=routine name -
ALIASES=alias names -
LOCAL=boolean value -
STANDARD_PROLOGUE=boolean value -
ENTRY=code entry point -
CODE_SECTION=code section psect name -
DATA_SECTION=data section psect name -
DATA_SECTION_POINTER=boolean value -
LINKAGE_SECTION=linkage section psect name -
KIND=routine type-
HANDLER_REINVOKABLE=boolean value -
BASE_REG_IS_FP=boolean value-
REI_RETURN=boolean value -
STACK_RETURN_VALUE=boolean value -
RSA_OFFSET=integer value -
SAVE_FP=register name -
SAVE_RA=return address register name -
SIZE=numeric value -
SAVED_REGS=list of registers -
HANDLER=exception handler address -
HANDLER_DATA=data address for exception handler -
SYNCH_EXCEPTIONS=boolean value-
PROC_VALUE=procedure value -
ENVIRONMENT=environment value -
FUNC_RETURN=function return type -
ARGLIST=argument type list -
USES_VAX_ARGLIST=boolean value -
OVERRIDE_FLAGS=procedure descriptor flags -
DEFAULT_SIGNATURE=boolean value -
COMMON_BASE=list of registers -
TARGET_INVO=boolean value -
EXCEPTION_MODE=mode -
19.20.1 – Parameters
NAME
The name of the routine. This argument is required for all
procedure kinds. There is no default. For example:
NAME=FOOZLE
ALIASES
List of alias names for the routine. This argument is optional
for all procedure types. There is no default. For example:
ALIASES=<FOO,BAR,FOOBAR,foo,bar,foobar,Foo,Bar,FooBar>
LOCAL
Boolean value indicating whether the routine is local (TRUE) or
externally visible (FALSE). This argument is optional for all
procedure kinds. The default is FALSE. For example:
LOCAL=TRUE
STANDARD_PROLOGUE
Specifies a Boolean value to indicate whether $ROUTINE should
generate a standard instruction prologue sequence at the
beginning of the routine's code section. This argument is
optional and valid only with REGISTER and STACK procedures. If
the procedure type is stack or register, the default is TRUE and
$ROUTINE generates a standard prologue sequence. The prologue
sequence generated by $ROUTINE saves the registers you specify
with the SAVED_REGS argument and performs stack-frame management
as necessary.
If you also specify BASE_REG_IS_FP=FALSE, the standard prologue
sequence generated by $ROUTINE makes a copy of the procedure
descriptor address that is in R27 upon entry into R29 (FP). While
you cannot change the value in R29 before the epilogue, you can
use R29 as a working, linkage-section register. If you specify
the STANDARD_PROLOGUE argument as FALSE, you must code your own
prologue sequence and mark the end of the prologue with the $END_
PROLOGUE macro. Whether or not you specify STANDARD_PROLOGUE as
TRUE or accept the default, you can generate a standard epilogue
sequence for stack and register procedures with the $RETURN
macro. For example:
STANDARD_PROLOGUE=FALSE
ENTRY
The name of the code-entry point. This argument is the code
entry-point label that $ROUTINE defines for you at the beginning
of the code section for the routine. If this argument is omitted,
$ROUTINE generates a label. For example:
ENTRY=FOOZLE_ENTRY
CODE_SECTION
The psect name and attributes of the code section. This argument
is optional for all procedure kinds. If omitted, the default
is the name and attributes defined by the $CODE$ lexical string
symbol. If you specify a name and attributes for the CODE_SECTION
argument, $ROUTINE redefines the $CODE$ lexical string symbol
such that the specified values become the new default. Initially,
$CODE$ is defined as follows:
$CODE$ = "$CODE$,OCTA,PIC,CON,REL,LCL,SHR,EXE,NORD,NOWRT"
Since you must delimit the psect name and attributes using
commas, be sure to enclose this argument within angle brackets
to avoid having the assembler interpret the name and attributes
as different arguments to $ROUTINE. For example:
CODE_SECTION=<MY_CODE,EXE,QUAD,NOWRT>
DATA_SECTION
The psect name and attributes of the data section. This argument
is optional for all procedure kinds. If omitted, the default
is the name and attributes defined by the $DATA$ lexical string
symbol. If you specify a name and attributes for the DATA_SECTION
argument, $ROUTINE redefines the $DATA$ lexical string symbol
such that the specified values become the new default. Initially,
$DATA$ is defined as follows:
$DATA$ = "$DATA$,OCTA,NOPIC,CON,REL,LCL,NOSHR,NOEXE,RD,WRT"
Since you must delimit the psect name and attributes using
commas, be sure to enclose this argument within angle brackets
to avoid having the assembler interpret the name and attributes
as different arguments to $ROUTINE. For example:
DATA_SECTION=<MY_DATA,NOEXE,QUAD,RD,WRT>
DATA_SECTION_POINTER
Boolean value indicating whether $ROUTINE should store a pointer
to the data section in the linkage section and define $DP as
the address of that pointer. This argument is optional for all
procedure kinds. The default is FALSE. For example:
DATA_SECTION_POINTER=TRUE
You can use the DATA_SECTION_POINTER argument as follows:
$ROUTINE TALLY_HO, DATA_SECTION_POINTER=TRUE
$DATA_SECTION
TALLY: .QUAD 0
$CODE_SECTION
.BASe R27, $LS ; Inform assembler that R27->$LS
LDQ R1, $DP ; R1->$DS
.BASE R1,$DS ;Inform assembler that R1-$DS
LDQ R0, TALLY ; R0<-TALLY
LDA R0, 1(R0) ; R0<-R0++
STQ R0, TALLY ; TALLY<-R0
RET (R26) ; Return
$END_ROUTINE TALLY_HO
In this example, the DATA_SECTION_POINTER argument is specified
in order to obtain linkage to the data section. The first LDQ
instruction loads R1 with the pointer to the data section
that $ROUTINE stores in the linkage section. The next three
instructions increment the value in the TALLY variable in the
data section. Finally, the routine returns the incremented value
to its caller in R0.
LINKAGE_SECTION
The psect name and attributes of the linkage section. This
argument is optional for all procedure kinds. If omitted, the
default is the name and attributes defined by the $LINK$ lexical
string symbol. If you specify a name and attributes for the
LINKAGE_SECTION argument, $ROUTINE redefines the $LINK$ lexical
string symbol such that the specified values become the new
default. Initially, $LINK$ is defined as follows:
$LINK$ = "$LINK$,OCTA,NOPIC,CON,REL,LCL,NOSHR,NOEXE,RD,NOWRT"
Since you must delimit the psect name and attributes using
commas, be sure to enclose this argument within angle brackets
to avoid having the assembler interpret the name and attributes
as different arguments to $ROUTINE. For example:
LINKAGE_SECTION=<MY_LINK,NOEXE,QUAD,RD,NOWRT>
KIND
Specifies the kind of routine being defined. This must be one
of the following: STACK, REGISTER, NULL, or BOUND. This is an
optional argument. The default is NULL. For example:
KIND=STACK
HANDLER_REINVOKABLE
Specifies a Boolean value to indicate whether the condition
handler can be re-invoked. This argument is optional and valid
only with STACK and REGISTER procedures. It defaults to FALSE
if no value is specified and the procedure kind is STACK or
REGISTER. Note that this argument is only valid if a value is
also specified for the HANDLER argument. For example:
HANDLER_REINVOKABLE=TRUE
BASE_REG_IS_FP
Specifies a Boolean value to indicate whether register R29
(FP) is used as the frame-pointer base register (TRUE) or not
(FALSE). If specified as FALSE, R29 must be used to hold the
address of the procedure descriptor (or the address of the
address of the procedure descriptor-see the OpenVMS Calling
Standard. You can use R29 to hold a working copy of the linkage-
section address passed in R27. In addition, your prologue and
epilogue instruction sequences can be shorter and more efficient.
However, you cannot make standard calls to other routines if
BASE_REG_IS_FP is specified as FALSE. This argument is optional
and valid only with stack and register procedure kinds. It
defaults to TRUE if the procedure type is stack or register.
For example:
BASE_REG_IS_FP=FALSE
REI_RETURN
Specifies a Boolean value to indicate whether this routine
returns using an REI instruction. This argument is optional and
valid only with STACK, REGISTER, and NULL procedure kinds. It
defaults to FALSE if the procedure kind is STACK, REGISTER, or
NULL. For example:
REI_RETURN=TRUE
STACK_RETURN_VALUE
This argument is obsolete. Do not specify this argument.
RSA_OFFSET
An integer value specifying the stack offset (in bytes) of the
register save area. This argument is optional and valid only
for STACK procedures. If you specify BASE_REG_IS_FP as TRUE,
the value you specify with RSA_OFFSET must be at least 8. RSA_
OFFSET defaults to 8 if BASE_REG_IS_FP is specified as TRUE, 0
otherwise. For example:
RSA_OFFSET=32
SAVE_FP
The register that contains a copy of the value of FP (R29) upon
entry to this routine. The prologue instruction sequence must
copy FP to the register specified by SAVE_FP and the epilogue
instruction sequence(s) must restore FP from the register
specified by SAVE_FP. This argument is required and only valid
for REGISTER procedures. There is no default. For example:
SAVE_FP=R1
SAVE_RA
The register that contains the return address. This argument
is optional and only valid for REGISTER procedures. If SAVE_RA
is not R26, the prologue instruction sequence must copy R26 to
the register specified by SAVE_RA and the epilogue instruction
sequence(s) must use the return address stored in the register
specified by SAVE_FP to affect its return to caller. SAVE_RA
defaults to R26 if the procedure kind is REGISTER. For example:
SAVE_RA=R22
SIZE
A numeric value that must be a multiple of 16 specifying the
size of the fixed-stack area in bytes. This parameter is valid
only for REGISTER and STACK procedure kinds. It defaults to the
minimum value possible given the other arguments you specify or
default. $ROUTINE computes the amount of stack storage needed for
the register save area (if any) and defines the $RSA_END symbol
to be the offset of the first byte beyond the register save area.
If you wish to allocate a fixed area of stack beyond the register
save area, you can specify an expression with the SIZE argument
that includes the term $RSA_END plus the amount of fixed-stack
storage you need for your application. For example:
SIZE=$RSA_END+32
SAVED_REGS
A list of registers saved on the stack by the prologue code of
this routine. It is valid only for STACK procedures and you must
specify at least FP (R29) with this argument. It defaults to FP
(R29) for STACK procedures. For example:
SAVED_REGS=<R5,FP,F2,F3,F4>
The OpenVMS Calling Standard specifies that registers R0, R1,
R28, R30 (SP), and R31 must never be saved and restored. If
you specify these registers with the SAVED_REGS argument, the
$ROUTINE macro issues a diagnostic warning message.
HANDLER
The address of an exception handler. It is optional and valid
only for STACK and REGISTER procedure kinds. By default, the
procedure is defined not to have an exception handler. For
example:
HANDLER=MY_HANDLER
HANDLER_DATA
The address of data for the specified handler, if any. This
argument is optional and valid only for stack and register
procedure kinds and has no default value. You cannot specify a
HANDLER_DATA argument if you do not specify the HANDLER argument.
For example:
HANDLER_DATA=MY_HANDLER_DATA
SYNCH_EXCEPTIONS
An argument to indicate whether exceptions must be synchronized
or not. This argument is optional with STACK and REGISTER
routines and is not allowed with other kinds of routines. This
argument defaults to TRUE if you specify an exception handler
with the HANDLER argument. Otherwise, it defaults to FALSE.
When this argument is TRUE and you specify or accept the default
STANDARD_PROLOGUE=TRUE, $ROUTINE generates a TRAPB instruction
as part of the standard prologue sequence. In addition, when this
argument is true, the $RETURN macro generates a TRAPB instruction
as part of the standard epilogue sequence. When this argument is
FALSE, neither $ROUTINE nor $RETURN generate TRAPB instructions.
PROC_VALUE
The procedure value of a bound procedure's parent. This argument
is required for BOUND procedures and is invalid for all other
procedure kinds. For example:
PROC_VALUE=PARENT_PROC
ENVIRONMENT
Specifies an environment value. This parameter is optional and
valid only for BOUND procedures. It has no default value. For
example:
ENVIRONMENT=0
FUNC_RETURN
Specifies the function return type. This argument is optional
and valid for all procedure kinds. If specified, it must be one
of the following: I64, D64, I32, U32, FF, FD, FG, FS, FT, FFC,
FDC, FGC, FSC, or FTC. These values correspond to those listed in
Table 3-7 of the OpenVMS Calling Standard that have an additional
"RASE$K_FR_" prefix. There is no default. For example:
FUNC_RETURN=U32
ARGLIST
Argument type list. This argument is optional and valid for
all procedure kinds. If the argument list contains one or more
elements, each of the first six elements must be one of the
following: Q, I32, U32, FF, FD, FG, FS, or FT. The seventh and
subsequent arguments (if any) must be either I32 or Q.
These values correspond to the PSIG$K_RA_* and MASE$K_MA_*
signature encodings in Table 3-6 of the OpenVMS Calling Standard.
There is no default. If you specify this argument, $ROUTINE
generates a procedure signature block. For example:
ARGLIST=<Q,I32,FF,FF,U32>.
USES_VAX_ARGLIST
Specifies a Boolean value indicating whether the routine uses a
VAX argument list. This argument is optional for all procedure
kinds and defaults to FALSE. If you specify this argument,
$ROUTINE generates a procedure signature block. For example:
USES_VAX_ARGLIST=TRUE
OVERRIDE_FLAGS
Specifies overriding flags for the PDSC$W_FLAGS field in the
procedure descriptor. This argument is optional and valid for
all procedure kinds. However, it is required for BOUND procedures
when the parameter specified with the PROC_VALUE argument is an
external or forward reference. There is no default. For example:
OVERRIDE_FLAGS=PARENT_FLAGS
DEFAULT_SIGNATURE
Specifies a Boolean value to indicate whether the standard
procedure signature is used. TRUE means to use the standard
signature. It is optional and valid for all procedure kinds.
The default is FALSE if you specify either the ARGLIST or USES_
VAX_ARGLIST arguments. Otherwise, the default is TRUE. Note that
this argument must be FALSE or blank if you specify either the
ARGLIST or USES_VAX_ARGLIST arguments. For example:
DEFAULT_SIGNATURE=TRUE
COMMON_BASE
An argument to specify one or more base registers that are used
in common with other routines. This argument is optional for
all routine kinds. By default, $ROUTINE invalidates any previous
.BASE directives that may be in effect when you invoke $ROUTINE.
In this way, you are prevented from inadvertently processing the
second or subsequent routines in a module with .BASE directives
in effect that apply only to a previous routine. However, you
may wish to share a common base register assignment between a
number of routines. To do so, you can reissue the appropriate
.BASE directive or directives after each invocation of $ROUTINE.
Alternatively, you can specify one or more common base registers
with the COMMON_BASE argument, and enter the appropriate .BASE
directive or directives only once at the beginning of the module.
Specify the value for the COMMON_BASE argument as a list of
integer registers. For example:
COMMON_BASE=<R5,R13>
In this example, $ROUTINE invalidates any previous .BASE
directives except those for registers R5 and R13. Previous .BASE
directives for registers R5 and R13 are unaffected.
TARGET_INVO
Specifies a Boolean value indicating whether or not the exception
handler for this procedure is invoked when this procedure is the
target of an invocation unwind. (TARGET_INVO=TRUE) causes the
exception handler to be invoked during an unwind. The default is
TARGET_INVO=FALSE.
EXCEPTION_MODE
An argument to specify one of the following exception modes with
STACK and REGISTER procedures:
o SIGNAL-raise all exceptions except underflow.
o SIGNAL_ALL-raise all exceptions.
o SILENT-raise no exceptions.
o FULL_IEEE-only raise exceptions as per IEEE control bits.
The default is EXCEPTION_MODE=SIGNAL.
19.20.2 – Description
$ROUTINE defines a routine, makes it the current routine, and
performs the following actions:
o Creates and associates a linkage section, code section, and
data section with the routine.
o Defines a procedure descriptor and optional signature block in
accordance with the values of macro arguments.
o Optionally stores a pointer to the data section within the
linkage section.
o Creates the following numeric and lexical symbols:
Symbol Description
$CS Address at start of the current routine's code
section.
$DS Address at start of the current routine's data
section.
$DP Optional address of a pointer to the current
routine's data section. This symbol has a value
that is an address in the current routine's
linkage section at which the $ROUTINE macro has
placed the address of the data section ($DS) as
follows:
$DP = .
.ADDRESS $DS
$DP enables you to access the data area of the
current routine from its linkage section.
$LS Address of the current routine's linkage section.
$SIZE Size of fixed area of stack frame of the current
routine. This symbol is valid only with STACK and
REGISTER routines.
$RSA_ The offset within the fixed-stack area to the
OFFSET register save area. This symbol is valid only with
STACK routines.
$RSA_END The offset within the fixed-stack area to the the
first byte beyond the end of the register save
area (if any).
$CODE$ A lexical string symbol that defines the routine's
code psect name and attributes.
$DATA$ A lexical symbol that defines the routine's data
psect name and attributes.
$LINK$ A lexical string symbol that defines the routine's
linkage psect name and attributes.
o Optionally generates a standard instruction prologue sequence
at the beginning of the code section.
If you specify /NAMES=AS_IS on the command line, all but
the last three of these symbols are defined in both complete
uppercase and complete lowercase. These symbols are intended
for your use outside of the macros themselves. For example,
the values of these numeric symbols may be useful as a
mnemonic when coding an instruction with a register as in
the following example:
lda SP,-$SIZE(SP)
The last three symbols, $CODE$, $DATA$, and $LINK$, are only
defined in uppercase. They are used by the $ROUTINE macro
for the default code, data, and linkage section psect names
and attributes. You can define these symbols before invoking
$ROUTINE to alter the default program sections as follows:
- $CODE$ = "MY_CODE,EXE,OCTA,SHR,NORD,NOWRT,GBL"
- $DATA$ = "MY_DATA,NOEXE,OCTA,NOSHR,RD,WRT,GBL"
- $LINK$ = "MY_LINK,NOEXE,OCTA,SHR,RD,NOWRT,GBL"
These statements cause $ROUTINE to use the previous psect
names and attributes by default. If you specify any of the
CODE_SECTION, DATA_SECTION, or LINKAGE_SECTION arguments in
your invocation of $ROUTINE, $ROUTINE uses the psect name and
attributes specified with the argument.
In addition, $ROUTINE redefines the corresponding $CODE$,
$DATA$, or $LINK$ lexical string symbol to the value
you specify when you specify any of the CODE_SECTION,
DATA_SECTION, or LINKAGE_SECTION arguments with $ROUTINE.
19.20.3 – Example
$ROUTINE MAIN1, KIND=NULL
$ROUTINE MAIN1, -
KIND=STACK, -
SIZE=48, -
SAVED_REGS=<R2,FP,F5>
20 – MACRO-64 Alpha Architecture Quick Reference
This topic provides figures and tables showing the data types
and addressing capabilities of the Alpha architecture. The
information is derived from the Alpha Architecture Quick
Reference Guide. Minor changes have been made to reflect the
usage of the Alpha architecture that is specific to MACRO-64.
For more information, see the Alpha Architecture Reference Manual
and the OpenVMS Calling Standard.
20.1 – Register Usage Conventions
Register Usage Conventions for OpenVMS Alpha lists the register
usage conventions for OpenVMS Alpha. MACRO-64 recognizes FP and
SP as register synonyms, but does not recognize AI, RA, or PV as
register synonyms.
Table 11 Register Usage Conventions for OpenVMS Alpha
R0 Int func ret value
R1 Scratch
R2-R15 Saved
R16- Argument
R21
R22- Scratch
R24
R25 AI Argument information
R26 RA Return address
R27 PV Procedure value
R28 Volatile scratch
R29 FP Stack frame base
R30 SP Stack pointer
R31 Zero
F0 F-P function ret value
F1 F-P complex func ret value
F2-F9 Saved
F10- Scratch
F15
F16- Argument
F22
F23- Scratch
F30
F31 Zero
20.2 – Instruction Operand Notation
Instruction Operand Notation shows the notation for instruction
operands. The notation format is as follows:
<name>.<access type><data type>
Table 12 Instruction Operand Notation
<name>:
disp Displacement field
fnc PALcode function field
Ra Integer register operand in the Ra field
Rb Integer register operand in the Rb field
#b Integer literal operand in the Rb field
Rc Integer register operand in the Rc field
Fa Floating-point register operand in the Ra field
Fb Floating-point register operand in the Rb field
Fc Floating-point register operand in the Rc field
<access type>:
a The operand is used in an address calculation to form an
effective address. The data-type code that follows indicates
the units of addressability (or scale factor) applied to
this operand when the instruction is decoded.
i The operand is an immediate literal.
m The operand is both read and written.
r The operand is read only.
w The operand is write only.
<data type>:
b Byte
f F_floating
g G_floating
l Longword
q Quadword
s IEEE single floating (S_floating)
t IEEE double floating (T_floating)
w Word
x The data type is specified by the instruction.
20.3 – Instruction Qualifier Notation
Instruction Qualifier Notation shows the notation for instruction
qualifiers.
Table 13 Instruction Qualifier Notation
/QualifierMeaning
C Chopped rounding
D Dynamic rounding
(mode determined by FPCR<DYN>)
I Inexact result enable
M Minus infinity rounding
S Software completion enable
U Floating underflow enable
V Integer overflow enable
20.4 – F-P Control Register (FPCR) Format
F-P Control Register (FPCR) Format shows the format for the F-P
control register.
Table 14 F-P Control Register (FPCR) Format
Bits Symbol Meaning
63 SUM Bitwise OR of <57:52>
62:60 RAZ Read as zero; ignored when written
/IGN
59:58 DYN IEEE rounding mode selected:
00 Chopped
01 Minus infinity
10 Normal rounding
11 Plus infinity
57 IOV Integer overflow of destination precision
56 INE Floating mathematically inexact result
55 UNF Floating underflow of destination exponent
54 OVF Floating overflow of destination exponent
53 DZE Floating divide with divisor of zero
52 INV Floating invalid operand value
51:0 RAZ Read as zero; ignored when written
/IGN
20.5 – Decodable Pseudo-Operations
Decodable Pseudo-Operations lists the decodable pseudo-operations
and their associated actual instructions.
Table 15 Decodable Pseudo-Operations
Pseudo- Actual
Operation Instruction
BR target BR R31,target
CLR Rx BIS R31,R31,Rx
FABS Fx,Fy CPYS F31,Fx,Fy
FCLR Fx CPYS F31,F31,Fx
FMOV Fx,Fy CPYS Fx,Fx,Fy
FNEG Fx,Fy CPYSN Fx,Fx,Fy
FNOP CPYS F31,F31,F31
MOV Lit,Rx LDA Rx,lit(R31)
MOV {Rx BIS R31,{Rx/Lit8},Ry
/Lit8},Ry
MF_FPCR Fx MF_FPCR Fx,Fx,Fx
MT_FPCR Fx MT_FPCR Fx,Fx,Fx
NEGF Fx,Fy SUBF F31,Fx,Fy
NEGF/S Fx,Fy SUBF/S F31,Fx,Fy
NEGG Fx,Fy SUBG F31,Fx,Fy
NEGG/S Fx,Fy SUBG/S F31,Fx,Fy
NEGL {Rx SUBL R31,{Rx/Lit},Ry
/Lit8},Ry
NEGL/V {Rx SUBL/V R31,{Rx/Lit},Ry
/Lit8},Ry
NEGQ {Rx SUBQ R31,{Rx/Lit},Ry
/Lit8},Ry
NEGQ/V {Rx SUBQ/V R31,{Rx/Lit},Ry
/Lit8},Ry
NEGS Fx,Fy SUBS F31,Fx,Fy
NEGS/SU Fx,Fy SUBS/SU F31,Fx,Fy
NEGS/SUI Fx,FY SUBS/SUI F31,Fx,Fy
NEGT Fx,Fy SUBT F31,Fx,Fy
NEGT/SU Fx,Fy SUBT/SU F31,Fx,Fy
NEGT/SUI Fx,FY SUBT/SUI F31,Fx,Fy
NOP BIS R31,R31,R31
NOT {Rx ORNOT R31,{Rx/Lit},Ry
/Lit8},Ry
SEXTL {Rx ADDL R31,{Rx/Lit},Ry
/Lit},Ry
UNOP LDQ_U R31,0(Rx)
20.6 – Common Architecture Opcodes in Numerical Order
This table lists the common architecture opcodes in numerical
order.
MACRO-64 Alpha Architecture Quick Reference
A.6 Common Architecture Opcodes in Numerical Order
Table_A-6_Common_Architecture_Opcodes_in_Numerical_Order
Opcode________________Opcode________________Opcode___
00 CALL_PAL 11.26 CMOVNE 15.01E CVTDG/C
01 OPC01 11.28 ORNOT 15.020 ADDG/C
02 OPC02 11.40 XOR 15.021 SUBG/C
03 OPC03 11.44 CMOVLT 15.022 MULG/C
04 OPC04 11.46 CMOVGE 15.023 DIVG/C
05 OPC05 11.48 EQV 15.02C CVTGF/C
06 OPC06 11.64 CMOVLE 15.02D CVTGD/C
07 OPC07 11.66 CMOVGT 15.02F CVTGQ/C
08 LDA 12.02 MSKBL 15.03C CVTQF/C
09 LDAH 12.06 EXTBL 15.03E CVTQG/C
0A OPC0A 12.0B INSBL 15.080 ADDF
0B LDQ_U 12.12 MSKWL 15.081 SUBF
0C OPC0C 12.16 EXTWL 15.082 MULF
0D OPC0D 12.1B INSWL 15.083 DIVF
0E OPC0E 12.22 MSKLL 15.09E CVTDG
0F STQ_U 12.26 EXTLL 15.0A0 ADDG
10.00 ADDL 12.2B INSLL 15.0A1 SUBG
10.02 S4ADDL 12.30 ZAP 15.0A2 MULG
10.09 SUBL 12.31 ZAPNOT 15.0A3 DIVG
10.0B S4SUBL 12.32 MSKQL 15.0A5 CMPGEQ
10.0F CMPBGE 12.34 SRL 15.0A6 CMPGLT
10.12 S8ADDL 12.36 EXTQL 15.0A7 CMPGLE
10.1B S8SUBL 12.39 SLL 15.0AC CVTGF
10.1D CMPULT 12.3B INSQL 15.0AD CVTGD
10.20 ADDQ 12.3C SRA 15.0AF CVTGQ
10.22 S4ADDQ 12.52 MSKWH 15.0BC CVTQF
10.29 SUBQ 12.57 INSWH 15.0BE CVTQG
10.2B S4SUBQ 12.5A EXTWH 15.100 ADDF/UC
10.2D CMPEQ 12.62 MSKLH 15.101 SUBF/UC
10.32 S8ADDQ 12.67 INSLH 15.102 MULF/UC
10.3B S8SUBQ 12.6A EXTLH 15.103 DIVF/UC
10.3D CMPULE 12.72 MSKQH 15.11E CVTDG
/UC
10.40 ADDL/V 12.77 INSQH 15.120 ADDG
/UC
10.49 SUBL/V 12.7A EXTQH 15.121 SUBG
/UC
10.4D CMPLT 13.00 MULL 15.122 MULG
/UC
10.60 ADDQ/V 13.20 MULQ 15.123 DIVG
/UC
10.69 SUBQ/V 13.30 UMULH 15.12C CVTGF
/UC
10.6D CMPLE 13.40 MULL/V 15.12D CVTGD
/UC
11.00 AND 13.60 MULQ/V 15.12F CVTGQ
/VC
11.08 BIC 14 OPC14 15.180 ADDF
/U
11.14 CMOVLBS 15.000 ADDF/C 15.181 SUBF
/U
11.16 CMOVLBC 15.001 SUBF/C 15.182 MULF
/U
11.20 BIS 15.002 MULF/C 15.183 DIVF
/U
11.24 CMOVEQ 15.003 DIVF/C 15.19E CVTDG
/U
15.1A0 ADDG/U 15.580 ADDF/SU 16.0A6 CMPTLT
15.1A1 SUBG/U 15.581 SUBF/SU 16.0A7 CMPTLE
15.1A2 MULG/U 15.582 MULF/SU 16.0AC CVTTS
15.1A3 DIVG/U 15.583 DIVF/SU 16.0AF CVTTQ
15.1AC CVTGF/U 15.59E CVTDG/SU 16.0BC CVTQS
15.1AD CVTGD/U 15.5A0 ADDG/SU 16.0BE CVTQT
15.1AF CVTGQ/V 15.5A1 SUBG/SU 16.0C0 ADDS
/D
15.400 ADDF/SC 15.5A2 MULG/SU 16.0C1 SUBS
/D
15.401 SUBF/SC 15.5A3 DIVG/SU 16.0C2 MULS
/D
15.402 MULF/SC 15.5AC CVTGF/SU 16.0C3 DIVS
/D
15.403 DIVF/SC 15.5AD CVTGD/SU 16.0E0 ADDT
/D
15.41E CVTDG/SC 15.5AF CVTGQ/SV 16.0E1 SUBT
/D
15.420 ADDG/SC 16.000 ADDS/C 16.0E2 MULT
/D
15.421 SUBG/SC 16.001 SUBS/C 16.0E3 DIVT
/D
15.422 MULG/SC 16.002 MULS/C 16.0EC CVTTS
/D
15.423 DIVG/SC 16.003 DIVS/C 16.0EF CVTTQ
/D
15.42C CVTGF/SC 16.020 ADDT/C 16.0FC CVTQS
/D
15.42D CVTGD/SC 16.021 SUBT/C 16.0FE CVTQT
/D
15.42F CVTGQ/SC 16.022 MULT/C 16.100 ADDS
/UC
15.480 ADDF/S 16.023 DIVT/C 16.101 SUBS
/UC
15.481 SUBF/S 16.02C CVTTS/C 16.102 MULS
/UC
15.482 MULF/S 16.02F CVTTQ/C 16.103 DIVS
/UC
15.483 DIVF/S 16.03C CVTQS/C 16.120 ADDT
/UC
15.49E CVTDG/S 16.03E CVTQT/C 16.121 SUBT
/UC
15.4A0 ADDG/S 16.040 ADDS/M 16.122 MULT
/UC
15.4A1 SUBG/S 16.041 SUBS/M 16.123 DIVT
/UC
15.4A2 MULG/S 16.042 MULS/M 16.12C CVTTS
/UC
15.4A3 DIVG/S 16.043 DIVS/M 16.12F CVTTQ
/VC
15.4A5 CMPGEQ/S 16.060 ADDT/M 16.140 ADDS
/UM
15.4A6 CMPGLT/S 16.061 SUBT/M 16.141 SUBS
/UM
15.4A7 CMPGLE/S 16.062 MULT/M 16.142 MULS
/UM
15.4AC CVTGF/S 16.063 DIVT/M 16.143 DIVS
/UM
15.4AD CVTGD/S 16.06C CVTTS/M 16.160 ADDT
/UM
15.4AF CVTGQ/S 16.06F CVTTQ/M 16.161 SUBT
/UM
15.500 ADDF/SUC 16.07C CVTQS/M 16.162 MULT
/UM
15.501 SUBF/SUC 16.07E CVTQT/M 16.163 DIVT
/UM
15.502 MULF/SUC 16.080 ADDS 16.16C CVTTS
/UM
15.503 DIVF/SUC 16.081 SUBS 16.16F CVTTQ
/VM
15.51E CVTDG/SUC 16.082 MULS 16.180 ADDS
/U
15.520 ADDG/SUC 16.083 DIVS 16.181 SUBS
/U
15.521 SUBG/SUC 16.0A0 ADDT 16.182 MULS
/U
15.522 MULG/SUC 16.0A1 SUBT 16.183 DIVS
/U
15.523 DIVG/SUC 16.0A2 MULT 16.1A0 ADDT
/U
15.52C CVTGF/SUC 16.0A3 DIVT 16.1A1 SUBT
/U
15.52D CVTGD/SUC 16.0A4 CMPTUN 16.1A2 MULT
/U
15.52F CVTGQ/SVC 16.0A5 CMPTEQ 16.1A3 DIVT
/U
16.1AC CVTTS/U 16.5AF CVTTQ/SV 16.7BC CVTQS
/SUI
16.1AF CVTTQ/V 16.5C0 ADDS/SUD 16.7BE CVTQT
/SUI
16.1C0 ADDS/UD 16.5C1 SUBS/SUD 16.7C0 ADDS
/SUID
16.1C1 SUBS/UD 16.5C2 MULS/SUD 16.7C1 SUBS
/SUID
16.1C2 MULS/UD 16.5C3 DIVS/SUD 16.7C2 MULS
/SUID
16.1C3 DIVS/UD 16.5E0 ADDT/SUD 16.7C3 DIVS
/SUID
16.1E0 ADDT/UD 16.5E1 SUBT/SUD 16.7E0 ADDT
/SUID
16.1E1 SUBT/UD 16.5E2 MULT/SUD 16.7E1 SUBT
/SUID
16.1E2 MULT/UD 16.5E3 DIVT/SUD 16.7E2 MULT
/SUID
16.1E3 DIVT/UD 16.5EC CVTTS/SUD 16.7E3 DIVT
/SUID
16.1EC CVTTS/UD 16.5EF CVTTQ/SVD 16.7EC CVTTS
/SUID
16.1EF CVTTQ/VD 16.6AC CVTST/S 16.7EF CVTTQ
/SVID
16.2AC CVTST 16.700 ADDS/SUIC 16.7FC CVTQS
/SUID
16.500 ADDS/SUC 16.701 SUBS/SUIC 16.7FE CVTQT
/SUID
16.501 SUBS/SUC 16.702 MULS/SUIC 17.010 CVTLQ
16.502 MULS/SUC 16.703 DIVS/SUIC 17.020 CPYS
16.503 DIVS/SUC 16.720 ADDT/SUIC 17.021 CPYSN
16.520 ADDT/SUC 16.721 SUBT/SUIC 17.022 CPYSE
16.521 SUBT/SUC 16.722 MULT/SUIC 17.024 MT_
FPCR
16.522 MULT/SUC 16.723 DIVT/SUIC 17.025 MF_
FPCR
16.523 DIVT/SUC 16.72C CVTTS/SUIC 17.02A FCMOVEQ
16.52C CVTTS/SUC 16.72F CVTTQ/SVIC 17.02B FCMOVNE
16.52F CVTTQ/SVC 16.73C CVTQS/SUIC 17.02C FCMOVLT
16.540 ADDS/SUM 16.73E CVTQT/SUIC 17.02D FCMOVGE
16.541 SUBS/SUM 16.740 ADDS/SUIM 17.02E FCMOVLE
16.542 MULS/SUM 16.741 SUBS/SUIM 17.02F FCMOVGT
16.543 DIVS/SUM 16.742 MULS/SUIM 17.030 CVTQL
16.560 ADDT/SUM 16.743 DIVS/SUIM 17.130 CVTQL/V
16.561 SUBT/SUM 16.760 ADDT/SUIM 17.530 CVTQL/SV
16.562 MULT/SUM 16.761 SUBT/SUIM 18.0000 TRAPB
16.563 DIVT/SUM 16.762 MULT/SUIM 18.0400 EXCB
16.56C CVTTS/SUM 16.763 DIVT/SUIM 18.4000 MB
16.56F CVTTQ/SVM 16.76C CVTTS/SUIM 18.4400 WMB
16.580 ADDS/SU 16.76F CVTTQ/SVIM 18.8000 FETCH
16.581 SUBS/SU 16.77C CVTQS/SUIM 18.A000 FETCH_M
16.582 MULS/SU 16.77E CVTQT/SUIM 18.C000 RPCC
16.583 DIVS/SU 16.780 ADDS/SUI 18.E000 RC
16.5A0 ADDT/SU 16.781 SUBS/SUI 18.F000 RS
16.5A1 SUBT/SU 16.782 MULS/SUI 19 PAL19
16.5A2 MULT/SU 16.783 DIVS/SUI 1A.0 JMP
16.5A3 DIVT/SU 16.7A0 ADDT/SUI 1A.1 JSR
16.5A4 CMPTUN/SU 16.7A1 SUBT/SUI 1A.2 RET
16.5A5 CMPTEQ/SU 16.7A2 MULT/SUI 1A.3 JSR_
COROUTINE
16.5A6 CMPTLT/SU 16.7A3 DIVT/SUI 1B PAL1B
16.5A7 CMPTLE/SU 16.7AC CVTTS/SUI 1C OPC1C
16.5AC CVTTS/SU 16.7AF CVTTQ/SVI 1D PAL1D
1E PAL1E 2A LDL_L 36 FBGE
1F PAL1F 2B LDQ_L 37 FBGT
20 LDF 2C STL 38 BLBC
21 LDG 2D STQ 39 BEQ
22 LDS 2E STL_C 3A BLT
23 LDT 2F STQ_C 3B BLE
24 STF 30 BR 3C BLBS
25 STG 31 FBEQ 3D BNE
26 STS 32 FBLT 3E BGE
27 STT 33 FBLE 3F BGT
28 LDL 34 BSR
29 LDQ 35 FBNE
20.7 – OpenVMS PALcode Instruction Summary
OpenVMS Unprivileged PALcode Instructions lists the OpenVMS
unprivileged PALcode instructions and OpenVMS Privileged PALcode
Instructions lists the OpenVMS privileged PALcode instructions.
Table 16 OpenVMS Unprivileged PALcode Instructions
Mnemonic Opcode Description
AMOVRM 00.00A1 Atomic move from register to memory
AMOVRR 00.00A0 Atomic move from register to register
BPT 00.0080 Breakpoint
BUGCHK 00.0081 Bugcheck
CHMK 00.0083 Change mode to kernel
CHME 00.0082 Change mode to executive
CHMS 00.0084 Change mode to supervisor
CHMU 00.0085 Change mode to user
GENTRAP 00.00AA Generate software trap
IMB 00.0086 I-stream memory barrier
INSQHIL 00.0087 Insert into longword queue at head
interlocked
INSQHILR 00.00A2 Insert into longword queue at head
interlocked resident
INSQHIQ 00.0089 Insert into quadword queue at head
interlocked
INSQHIQR 00.00A4 Insert into quadword queue at head
interlocked resident
INSQTIL 00.0088 Insert into longword queue at tail
interlocked
INSQTILR 00.00A3 Insert into longword queue at tail
interlocked resident
INSQTIQ 00.008A Insert into quadword queue at tail
interlocked
INSQTIQR 00.00A5 Insert into quadword queue at tail
interlocked resident
INSQUEL 00.008B Insert entry into longword queue
INSQUEL/D 00.008D Insert entry into longword queue deferred
INSQUEQ 00.008C Insert entry into quadword queue
INSQUEQ/D 00.008E Insert entry into quadword queue deferred
PROBER 00.008F Probe for read access
PROBEW 00.0090 Probe for write access
RD_PS 00.0091 Move processor status
READ_UNQ 00.009E Read unique context
REI 00.0092 Return from exception or interrupt
REMQHIL 00.0093 Remove from longword queue at head
interlocked
REMQHILR 00.00A6 Remove from longword queue at head
interlocked resident
REMQHIQ 00.0095 Remove from quadword queue at head
interlocked
REMQHIQR 00.00A8 Remove from quadword queue at head
interlocked resident
REMQTIL 00.0094 Remove from longword queue at tail
interlocked
REMQTILR 00.00A7 Remove from longword queue at tail
interlocked resident
REMQTIQ 00.0096 Remove from quadword queue at tail
interlocked
REMQTIQR 00.00A9 Remove from quadword queue at tail
interlocked resident
REMQUEL 00.0097 Remove entry from longword queue
REMQUEL/D 00.0099 Remove entry from longword queue deferred
REMQUEQ 00.0098 Remove entry from quadword queue
REMQUEQ/D 00.009A Remove entry from quadword queue deferred
RSCC 00.009D Read system cycle counter
SWASTEN 00.009B Swap AST enable for current mode
WRITE_UNQ 00.009F Write unique context
WR_PS_SW 00.009C Write processor status software field
Table 17 OpenVMS Privileged PALcode Instructions
Mnemonic Opcode Description
CFLUSH 00.0001 Cache flush
CSERVE 00.0009 Console service
DRAINA 00.0002 Drain aborts
HALT 00.0000 Halt processor
LDQP 00.0003 Load quadword physical
MFPR_ASN 00.0006 Move from processor register ASN
MFPR_ESP 00.001E Move from processor register ESP
MFPR_FEN 00.000B Move from processor register FEN
MFPR_IPL 00.000E Move from processor register IPL
MFPR_MCES 00.0010 Move from processor register MCES
MFPR_PCBB 00.0012 Move from processor register PCBB
MFPR_PRBR 00.0013 Move from processor register PRBR
MFPR_PTBR 00.0015 Move from processor register PTBR
MFPR_SCBB 00.0016 Move from processor register SCBB
MFPR_SISR 00.0019 Move from processor register SISR
MFPR_SSP 00.0020 Move from processor register SSP
MFPR_TBCHK 00.001A Move from processor register TBCHK
MFPR_USP 00.0022 Move from processor register USP
MFPR_VPTB 00.0029 Move from processor register VPTB
MFPR_WHAMI 00.003F Move from processor register WHAMI
MTPR_ASTEN 00.0026 Move to processor register ASTEN
MTPR_ASTSR 00.0027 Move to processor register ASTSR
MTPR_DATFX 00.002E Move to processor register DATFX
MTPR_ESP 00.001F Move to processor register ESP
MTPR_FEN 00.000B Move to processor register FEN
MTPR_IPIR 00.000D Move to processor register IPRI
MTPR_IPL 00.000E Move to processor register IPL
MTPR_MCES 00.0011 Move to processor register MCES
MTPR_PERFMON 00.002B Move to processor register PERFMON
MTPR_PRBR 00.0014 Move to processor register PRBR
MTPR_SCBB 00.0017 Move to processor register SCBB
MTPR_SIRR 00.0018 Move to processor register SIRR
MTPR_SSP 00.0021 Move to processor register SSP
MTPR_TBIA 00.001B Move to processor register TBIA
MTPR_TBIAP 00.001C Move to processor register TBIAP
MTPR_TBIS 00.001D Move to processor register TBIS
MTPR_TBISD 00.0024 Move to processor register TBISD
MTPR_TBISI 00.0025 Move to processor register TBISI
MTPR_USP 00.0023 Move to processor register USP
MTPR_VPTB 00.002A Move to processor register VPTB
STQP 00.0004 Store quadword physical
SWPCTX 00.0005 Swap privileged context
SWPPAL 00.000A Swap PALcode image
20.8 – PALcode Opcodes in Numerical Order
PALcode Opcodes in Numerical Order lists the PALcode opcodes in
numerical order.
Table 18 PALcode Opcodes in Numerical Order
Opcode(16Opcode(10)penVMS
00.0000 00.0000 HALT
00.0001 00.0001 CFLUSH
00.0002 00.0002 DRAINA
00.0003 00.0003 LDQP
00.0004 00.0004 STQP
00.0005 00.0005 SWPCTX
00.0006 00.0006 MFPR_ASN
00.0007 00.0007 MTPR_ASTEN
00.0008 00.0008 MTPR_ASTSR
00.0009 00.0009 CSERVE
00.000A 00.0010 SWPPAL
00.000B 00.0011 MFPR_FEN
00.000C 00.0012 MTPR_FEN
00.000D 00.0013 MTPR_IPIR
00.000E 00.0014 MFPR_IPL
00.000F 00.0015 MTPR_IPL
00.0010 00.0016 MFPR_MCES
00.0011 00.0017 MTPR_MCES
00.0012 00.0018 MFPR_PCBB
00.0013 00.0019 MFPR_PRBR
00.0014 00.0020 MTPR_PRBR
00.0015 00.0021 MFPR_PTBR
00.0016 00.0022 MFPR_SCBB
00.0017 00.0023 MTPR_SCBB
00.0018 00.0024 MTPR_SIRR
00.0019 00.0025 MFPR_SISR
00.001A 00.0026 MFPR_TBCHK
00.001B 00.0027 MTPR_TBIA
00.001C 00.0028 MTPR_TBIAP
00.001D 00.0029 MTPR_TBIS
00.001E 00.0030 MFPR_ESP
00.001F 00.0031 MTPR_ESP
00.0020 00.0032 MFPR_SSP
00.0021 00.0033 MTPR_SSP
00.0022 00.0034 MFPR_USP
00.0023 00.0035 MTPR_USP
00.0024 00.0036 MTPR_TBISD
00.0025 00.0037 MTPR_TBISI
00.0026 00.0038 MFPR_ASTEN
00.0027 00.0039 MFPR_ASTSR
00.0029 00.0040 MFPR_VPTB
00.002A 00.0041 MTPR_VPTB
00.002B 00.0042 MTPR_PERFMON
00.002E 00.0043 MTPR_DATFX
00.003F 00.0063 MFPR_WHAMI
00.0080 00.0128 BPT
00.0081 00.0129 BUGCHK
00.0082 00.0130 CHME
00.0083 00.0131 CHMK
00.0084 00.0132 CHMS
00.0085 00.0133 CHMU
00.0086 00.0134 IMB
00.0087 00.0135 INSQHIL
00.0088 00.0136 INSQTIL
00.0089 00.0137 INSQHIQ
00.008A 00.0138 INSQTIQ
00.008B 00.0139 INSQUEL
00.008C 00.0140 INSQUEQ
00.008D 00.0141 INSQUEL/D
00.008E 00.0142 INSQUEQ/D
00.008F 00.0143 PROBER
00.0090 00.0144 PROBEW
00.0091 00.0145 RD_PS
00.0092 00.0146 REI
00.0093 00.0147 REMQHIL
00.0094 00.0148 REMQTIL
00.0095 00.0149 REMQHIQ
00.0096 00.0150 REMQTIQ
00.0097 00.0151 REMQUEL
00.0098 00.0152 REMQUEQ
00.0099 00.0153 REMQUEL/D
00.009A 00.0154 REMQUEQ/D
00.009B 00.0155 SWASTEN
00.009C 00.0156 WR_PS_SW
00.009D 00.0157 RSCC
00.009E 00.0158 READ_UNQ
00.009F 00.0159 WRITE_UNQ
00.00A0 00.0160 AMOVRR
00.00A1 00.0161 AMOVRM
00.00A2 00.0162 INSQHILR
00.00A3 00.0163 INSQTILR
00.00A4 00.0164 INSQHIQR
00.00A5 00.0165 INSQTIQR
00.00A6 00.0166 REMQHILR
00.00A7 00.0167 REMQTILR
00.00A8 00.0168 REMQHIQR
00.00A9 00.0169 REMQTIQR
00.00AA 00.0170 GENTRAP
20.9 – Common Architecture Instructions
21 – Using LSE with MACRO-64
This topic explains how to use the Language-Sensitive Editor
(LSE) with the MACRO-64 language. For LSE to function correctly,
LSE must be installed prior to the MACRO-64 assembler.
21.1 – Invoking LSE
To use LSE with the MACRO-64 language, you must name your program
source file with a .M64 file extension. For example, to edit a
file named TEST.M64, enter the following command:
$ LSE TEST.M64
Using the .M64 file extension invokes the LSE editor and places
you in the MACRO-64 language environment.
If you choose to use a different file extension, you can still
use LSE in the MACRO-64 language environment. For example, to
edit a file named TEST.ASM, enter the following command:
$ LSE/LANGUAGE=MACRO64 TEST.ASM
If you use LSE with MACRO-64, and you want the same behavior on
the OpenVMS Alpha operating system as on the OpenVMS VAX operating
system, enter the following LSE command:
$ SET COMMAND LANGUAGE VMS
21.2 – Running Diagnostics
You can run diagnostics in LSE to debug programs without leaving
the LSE editor. For more information, see the Guide to Language-
Sensitive Editor for VMS Systems and the MACRO-64 release notes.
When running diagnostics in an LSE editing session, MACRO-64
displays error messages of different severity levels.
22 – Error Messages
The description of each message gives the severity, followed by
additional explanatory text and suggested action.
22.1 – ADDTRUNC
Storing an address expression into a storage allocation less than
the size of an address results in data truncation.
Informational: The assembler stored a value that is too large for
the allocated space, resulting in data truncation.
User Action: Allocate more storage.
22.2 – ALIGNFILLIGN
The optional .ALIGN fill pattern argument is ignored in psects with
the EXE and NOMIX attributes.
Warning: The optional fill pattern is ignored because it is
only valid for psects that do not possess the EXE and NOMIX
attributes.
User Action: Omit the fill pattern or specify the MIX psect
attribute.
22.3 – ALIGNFILLTRUNC
The value you specify for the .ALIGN optional fill pattern must be
an integer in the range of 0 . . . 255. Data truncation occurs with
the currently specified fill pattern in a byte storage location.
Warning: The value you specify as the fill pattern for the .ALIGN
directive must be within the range of 0 . . . 255. Data truncation
occurs whenever you specify a value that is outside of this
range.
User Action: Specify a smaller value for the fill pattern.
22.4 – ALIGNLABELIGN
The ALIGN_LABEL option has been replaced by the ALIGN_CODE option.
Error: The ALIGN_LABEL option has been replaced by the ALIGN_CODE
option.
User Action: Use the recommended new option.
22.5 – ALIGNTOBIG
Specified alignment is too large for PSECT.
Error: The alignment you specified is too large for the current
psect.
User Action: Check the psect attributes to insure that the psect
alignment is greater than or equal to the alignment you are
requesting.
22.6 – ASCIITRUNC
ASCII constant contains too many characters; value is truncated.
Error: Your ASCII constant contains more than eight characters
with the ^A or ^a radix specifier. The assembler deletes the
extra characters.
User Action: Check your source code. Use eight or less
characters.
22.7 – BADALIGN
Alignment specifier is out of range.
Error: The alignment specifier used with the .PSECT or .ALIGN
directive is out of range.
User Action: See the descriptions of the .PSECT and .ALIGN
directives.
22.8 – BADENDARG
Bad argument to .END directive.
Error: The optional argument to the .END directive is invalid.
User Action: If you specify the argument, it must reference a
procedure descriptor within the module. Specify a valid procedure
descriptor name or omit the argument.
22.9 – BADINSARG
Argument N is invalid for this instruction.
Error: The argument number shown is invalid for the instruction.
User Action: Check the argument and required format as specified
in the documentation.
22.10 – BADLIB
Error opening library file XXXXX.
Error: The assembler encountered an error when attempting to open
the indicated library file.
User Action: Check the file format and file protections.
22.11 – BADMACPARAMNAME
Illegal macro parameter name.
Error: The indicated macro parameter name is illegal.
User Action: Examine your source code and see Chapter 1 in the
Reference Manual for information about valid parameter names.
22.12 – BADMACRONAME
Illegal macro name.
Error: The indicated macro name is illegal.
User Action: Check your source code and see Chapter 2 in the
Reference Manual for information about valid macro names.
22.13 – BADOPERAND
Invalid operand type for operator.
Error: The resolved operand type is invalid for the specified
operator.
User Action: See Chapter 2 in the Reference Manual for
descriptions of operators, operands, and expressions.
22.14 – BADPARAMSTR
Illegal parameter string.
Error: The string specified as a macro parameter is invalid.
User Action: Examine your source code and see Chapter 1 in the
Reference Manual for information about valid parameter names.
22.15 – BADSYSCALL
Internal error. Bad system call.
Error: The assembler encountered an unexpected internal error
when performing a system call.
User Action: Report the problem to Digital.
22.16 – BASEFAIL
Argument N is invalid. The assembler failed to find a base register
specified with a previous .BASE directive to form a register
expression of the form offset(Rn).
Error: The assembler could not find a base register, which
you specified with a previous .BASE directive, to form a valid
register expression of the form offset(Rn).
User Action: Check the instruction in the source code and see the
description of the .BASE directive.
22.17 – BASERANGE
Argument N invalid. The assembler attempted to use base register Rn
to form a register expression of the form offset(Rn). However, the
argument offset exceeds the allowable range of -32,768 to +32,767.
Error: The assembler attempted to use a base register, which
you specified with a previous .BASE directive, to form a valid
register expression of the form offset(Rn). This attempt failed
because the specified argument offset exceeded the valid range of
the base register offset (_32,768 to +32,767). The register cited
in the message represents the register that produced an offset
closest to the range of -32,768 to +32,767.
User Action: Check the instruction in the source code and see
description of the .BASE directive.
22.18 – BEGEXPSC
.BEGIN_EXACT is invalid in a psect with the NOEXE and NOMIX
attributes.
Error: A .BEGIN_EXACT directive is not valid in a psect with the
NOEXE and NOMIX attributes.
User Action: Check your source code.
22.19 – BYTEALIGNIGN
The BYTE_ALIGN option has been replaced by the ALIGN_DATA option.
Error: The BYTE_ALIGN option has been replaced by the ALIGN_DATA
option.
User Action: Use the recommended new option.
22.20 – CONPSECTATTR
Contradictory PSECT attribute.
Error: A previously specified psect attribute conflicts with the
flagged psect attribute.
User Action: See the description of the .PSECT directive and
psect attributes.
22.21 – CONTEOF
Assembler encountered end of file after line continuation.
Error: The assembler encountered end of file after a line that
specified a continuation.
User Action: Check your source code.
22.22 – DATAALIGNTOBIG
Data requires alignment too large for PSECT.
Error: The alignment required for a specified data item is too
large for the psect.
User Action: Check the psect attributes to insure that the psect
alignment is greater than or equal to the required alignment of
the data items. See the description of the .PSECT directive and
psect attributes.
22.23 – DATANOTINNOEXE
Data declarations must be in a psect with the MIX or NOEXE
attribute.
Error: A data declaration, such as a data-storage directive, has
been specified in a psect with incorrect psect attributes.
User Action: Make sure the psect has the MIX or NOEXE attribute
set. See the description of the .PSECT directive and psect
attributes.
22.24 – DIRNOTINNOEXE
Directive must be in a psect with the MIX or NOEXE attribute.
Error: The directive you specify must appear in a psect with the
MIX or NOEXE attribute set.
User Action: Make sure you specify a psect with the MIX or NOEXE
attribute set. See the description of the .PSECT directive and
psect attributes.
22.25 – DISPTOOLGE
Branch offset is too large for this instruction.
Error: The offset you specified is too large for this
instruction.
User Action: Check the range of the specified target to insure it
falls between -1048576 . . . +1048575, inclusive.
22.26 – DUPLEXTERN
External item has multiple definitions.
Error: The item you declared as externally defined with the
.EXTERNAL attribute has another conflicting definition within
this assembly unit.
User Action: Check the definitions for the specified item.
22.27 – DUPLGLOBAL
Duplicate global name.
Warning: The assember detected a duplicate global name.
User Action: Check all references in your source code to this
name.
22.28 – DUPMACPARAMNAME
Duplicate macro parameter name.
Error: The assembler detected a duplicate macro parameter name.
User Action: Check your source code.
22.29 – ENDEXPSC
.END_EXACT is invalid in a psect with the NOEXE and NOMIX
attributes.
Error: A .END_EXACT directive is not valid in a psect with the
NOEXE and NOMIX attributes.
User Action: Check your source code.
22.30 – EOLEXP
Assembler expected an end of line.
Error: The assembler expected no more input from the current
line.
User Action: Check your source code.
22.31 – ESCAPE
Illegal escape sequence in string literal; assembler expected \, ",
x, or X.
Error: The escape sequence you specified in the string literal is
illegal.
User Action: Check your source code.
22.32 – EXP32BITTRUNC
Assembler expected an integer in the range 0 . . . (2^32)-1 for
an unsigned expression OR -(2^31) . . . +(2^31)-1 for a signed
expression. Data truncation to 32 bits.
Warning: The assembler found an integer that was not within the
expected range.
User Action: Check your source code. The literal must be within
the range of 0 . . . (2^32)-1 for an unsigned expression OR
-(2^31) . . . +(2^31)-1 for a signed expression. Data truncation
to 32 bits occurs.
22.33 – EXP32BITTYPE
Assembler expected an integer in the range 0 . . . (2^32)-1 for
unsigned expression OR -(2^31) . . . +(2^31)-1 for signed expression.
Error: The assembler expected an unsigned integer value within
the range of 0 . . . (2^32)-1 or a signed integer value within in
the range of -(2^31) . . . +(2^31)-1.
User Action: Check your source code.
22.34 – EXPBINEXPTERM
Assembler found XXXXX when expecting a binary operator or expression
terminator.
Error: The assembler expected a binary operator, such as the plus
sign (+) for binary addition, or an item to end the expression,
such as the right-angle bracket (>).
User Action: Check the flagged item in the source statement.
22.35 – EXPFPREG
Argument N is invalid. Assembler expected a floating point register.
Error: The instruction argument cited is invalid. The assembler
expected a floating-point register.
User Action: Check your source code and the instruction
documentation.
22.36 – EXPGENREG
Argument N is invalid. Assembler expected a general register.
Error: The instruction argument cited is invalid. The assembler
expected a general register.
User Action: Check your source code and the instruction
documentation.
22.37 – EXPIDPROC
Argument N is invalid. Assembler expected an identifier representing
a procedure value.
Error: The argument cited is invalid. The assembler expected a
user identifier that represents a procedure value.
User Action: Check your source code and the instruction
documentation.
22.38 – EXPINTPAL
Assembler expected an integer expression or PAL opcode.
Error: Integer expession or PAL opcode missing.
User Action: Replace the flagged item with an integer or PAL
opcode.
22.39 – EXPLAB
Argument N is invalid. Assembler expected a label defined in the
same psect.
Error: The cited argument is invalid. The assembler expected a
label definition to occur in the same psect as its reference.
User Action: Check your source code and the instruction
documentation.
22.40 – EXPLITVAL
Argument N is invalid. Assembler expected an integer literal value
in the inclusive range 0 . . . 255.
Error: The instruction argument cited is invalid. The assembler
expected an integer literal within the range of 0 . . . 255.
User Action: Check your source code and the instruction
documentation.
22.41 – EXPMACRONAME
Assembler expected a valid macro name.
Error: The assembler expected a valid macro name in this context.
User Action: Check your source code to insure that the item
flagged is a user identifier, opcode, or nonmacro directive.
22.42 – EXPPALOPLIT
Argument N is invalid. Assembler expected an integer literal value
in the inclusive range 0 . . . 67108863.
Error: The instruction argument cited is invalid. The assembler
expected an integer literal.
User Action: Check your source code and the instruction
documentation.
22.43 – EXPREGOFF
Argument N is invalid. Assembler expected a general register
expression of the form offset(Rn).
Error: The cited argument is invalid. The assembler expected a
general register expression of the form integer_offset(Rn) for
this argument.
User Action: Check the source code and the instruction
documentation.
22.44 – EXPRESEXP
Argument N is invalid. Assembler expected an expression with no
forward references resolvable to psect +/- offset.
Error: The argument cited is invalid. The assembler expected an
expression with no forward references.
User Action: Check your source code and the instruction
documentation.
22.45 – EXPSTACKOVER
Internal SEM expression stack overflow.
Fatal: An internal error has occurred.
User Action: Gather as much information as possible about the
circumstances under which the error occurred and report the
problem to Digital.
22.46 – EXPTOOCMPLX
Expression is too complex to evaluate.
Error: The expression is too complex for the assembler to
evaluate.
User Action: Try grouping the expression components using angle
brackets (< >). The most complex expression form handled by
the assembler resolves to the form: <psect/symbol +/- offset>
OPERATOR <psect/symbol +/- offset>, where OPERATOR is one of: +,
-, *, /, @, \, &, or !. See Chapter 2 in the Reference Manual for
further descriptions of the assembler evaluation of expressions.
22.47 – EXPZEROFF
Argument N is invalid. Assembler expected a general register
expression of the form 0(Rn) or (Rn).
Error: The cited argument is invalid. The assembler expected a
general register expression of the form 0(Rn).
User Action: Check your source code and see Chapter 2 in
the Reference Manual for information about general register
expressions.
22.48 – FOUNDEXP
Assembler found XXXXX when expecting one of the following: XXXXX.
Error: The assembler found an unexpected item in a location where
it expected something else.
User Action: Check the unexpected item found in the source
statement. Examine those items cited as expected as alternatives
for the unexpected item.
22.49 – FREGDEF
You cannot define a floating-point register in terms of an integer
register.
Warning: You are attempting to define a floating-point register
symbol in terms of an integer register.
User Action: Specify either a floating-point register or an
expression within the range of 0 to 31 with the .DEFINE_FREG
directive. See the description of the .DEFINE_FREG directive.
22.50 – GENERROR
Generated ERROR:
Error: This statement was generated using the .ERROR directive.
User Action: Examine your source code.
22.51 – GENPRINT
Generated PRINT:
Informational: This statement was generated using the .PRINT
directive.
User Action: Examine your source code.
22.52 – GENWARN
Generated WARNING:
Warning: This statement was generated using the .WARNING
directive.
User Action: Examine your source code.
22.53 – HEXSTR
Illegal hexadecimal escape sequence in string literal.
Error: The specified hexadecimal escape sequence is invalid.
User Action: Check your source code and the documentation.
22.54 – IDENTTRUNC
The string length of the module IDENT is greater than 31 characters.
It is truncated to 31 characters.
Warning: The string argument you specified with the .IDENT
directive is too long.
User Action: Specify a shorter string argument. See the
description of the .IDENT directive.
22.55 – IDFOUND
Assembler found identifier in the opcode field when expecting one
of the following: opcode, directive, macro invocation, or symbol
definition.
Error: The identifier cited was unexpected. The assembler
expected either an opcode, a directive, a macro invocation, or
a symbol definition.
User Action: Check your source code.
22.56 – IDTOOLONG
Identifier is longer than 31 characters.
Error: The identifier exceeds the 31 character maximum size.
User Action: Check your source code and either rename or truncate
the identifier.
22.57 – ILLASCII
Illegal ASCII constant.
Error: The assembler found an illegal ASCII constant with the 6A
or ^a radix specifier.
User Action: Check your source code.
22.58 – ILLBIN
Illegal binary constant.
Error: The assembler found an illegal binary constant with the ^B
or ^b radix specifier.
User Action: Check your source code.
22.59 – ILLDEC
Illegal decimal constant.
Error: The assembler found an illegal binary constant with the ^D
or ^d radix specifier.
User Action: Check your source code.
22.60 – ILLEXPON
Illegal exponent in floating-point constant.
Error: The specified exponent of the floating-point constant is
illegal.
User Action: Check your source code and see Chapter 5 in the
Reference Manual for information about floating-point constants.
22.61 – ILLFLOAT
Illegal floating-point constant.
Error: The specified floating-point constant is illegal.
User Action: Check your source code and see Chapter 5 in the
Reference Manual for information about floating-point constants.
22.62 – ILLHEX
Illegal hexadecimal constant.
Error: The assembler found an illegal binary constant with the ^X
or ^x radix specifier.
User Action: Check your source code.
22.63 – ILLIFOP
Illegal .IF operator.
Error: An illegal operator was encountered as an .IF operator.
User Action: Check your source code and see the description of
the .IF directive.
22.64 – ILLINCL
Illegal .INCLUDE file specification.
Error: The assembler encountered an illegal .INCLUDE directive.
User Action: Check your source code and see the description of
the .INCLUDE directive.
22.65 – ILLOCT
Illegal octal constant.
Error: The assembler found an illegal binary constant with the ^O
or ^o radix specifier.
User Action: Check your source code.
22.66 – ILLOPERANDMIX
Illegal operand mixing for operator.
Error: The resolved operand types are invalid when used together
with the specified operator.
User Action: See Chapter 2 in the Reference Manual for
descriptions of operators, operands, and expressions.
22.67 – ILLPROCRET
Illegal procedure return; linkage register (argument 1) must be R31
when software hint (argument 3) is 1.
Error: Illegal procedure return.
User Action: Check the instruction arguments. When argument 3,
software hint, is 1, the first argument specifying the linkage
register must be R31.
22.68 – ILLRADIX
Illegal radix specifier in numeric constant; specify A, B, C, D, O,
or X.
Error: The assembler found an illegal radix specifier.
User Action: Check your source code and use one of A, B, C, D, O,
or X.
22.69 – INCLDEPTH
.INCLUDE nest depth exceeds N - check for circular .INCLUDE.
Error: The assembler attempted to exceed the maximum level of
include file depth.
User Action: Check your source code for circular file inclusion.
22.70 – INCLOPEN
.INCLUDE file open error.
Error: The assembler could not open the included file.
User Action: Check the file attributes and so forth of the
specified .INCLUDE file.
22.71 – INSNOTINPSC
Instructions must be in a MIX, NOEXE; MIX, EXE; or NOMIX, EXE PSECT.
Error: You specified an instruction in a psect with incorrect
psect attributes.
User Action: Make sure the psect has MIX or EXE and NOMIX
attributes set.
22.72 – INTERNAL
Internal assembler error. Please report the problem to Digital.
Fatal: An internal error has occurred.
User Action: Gather as much information as possible about the
circumstances under which the error occurred and report the
problem to Digital.
22.73 – INTERR
Internal processing error in the SYN facility. Please report the
problem to Digital.
Fatal: An internal error has occurred.
User Action: Gather as much information as possible about the
circumstances under which the error occurred and report the
problem to Digital.
22.74 – INVALIGNFILL
You specified an invalid optional fill pattern with the .ALIGN
directive.
Error: You specified an invalid optional fill pattern.
User Action: Check your source code, in particular the second
argument to the .ALIGN directive, the alignment fill specifier,
to insure that it resolves to an integer. See the description of
the .ALIGN directive.
22.75 – INVBASEEXP
Invalid expression for .BASE directive.
Error: The expression is not valid for .BASE directive.
User Action: The expression you specified for a base register
with the .BASE directive should contain no forward references and
resolve to one of the following at this point in assembly: psect
+/- offset, external symbol reference +/- offset, integer, label
+/- offset, where the label is defined in a psect with the EXE
and NOMIX attributes. See Chapter 5 in the Reference Manual for
more information about the assembler evaluation of expressions.
22.76 – INVBASEREG
Invalid base register. Base register must be one of R0 through R30.
Error: You specified an invalid base register.
User Action: Specify a base register as a general register from
the range of R0 . . . R30. R31 cannot be specified as a base
register and is implicitly defined as .BASE R31, 0.
22.77 – INVBRTGT
Invalid branch target. Branch target label must be defined in same
psect as the branch instruction which references the label.
Error: The specified label you reference as the target of a
branch instruction must be defined in the same psect in which
it is referenced.
User Action: See Chapter 4 in the Reference Manual for more
information about labels.
22.78 – INVCA
You specified an invalid code address with the procedure descriptor.
The code address must be a nontemporary label defined in a psect
with the EXE or MIX attribute after its use with .PROCEDURE_
DESCRIPTOR.
Error: The code address you specified as the second argument to
the .PROCEDURE_DESCRIPTOR directive is invalid.
User Action: The code address must be a non-temporary label
defined in a psect with the EXE or NOMIX attribute. Check your
source code.
22.79 – INVEXP
Assembler found XXXXX when expecting a valid expression.
Error: The assembler expected one of the following: integer,
floating-point constant, identifier, register, period (.), left-
angle bracket (<), or unary operator.
User Action: Check the unexpected item found in the source
statement.
22.80 – INVEXPRFORDIR
Invalid expression type for directive.
Error: The assembler resolved value for the expression in the
cited directive is invalid.
User Action: See Chapters 1 and 5 in the Reference Manual for
more information about the directive arguments and types.
22.81 – INVEXPRFORSYM
Invalid expression type for symbol.
Error: The assembler resolved value for the expression that is
assigned to a local or global symbol is invalid.
User Action: Expressions assigned to a symbol must contain no
forward references and must resolve to an integer or psect
/label +/- offset. See Chapter 2 in the Reference Manual for
more information about how the assembler determines symbol and
expression values.
22.82 – INVFPCONST
Invalid floating-point value. Check value range for floating-point
data type.
Error: The assembler detected an invalid floating-point value.
User Action: Check the specified range for the directive type.
22.83 – INVINSQUAL
You specified an invalid instruction qualifier list for the opcode.
Error: The instruction qualifier you specified with the opcode is
invalid.
User Action: See Appendix A in the Reference Manual for a
complete list of opcodes and valid instruction qualifiers.
22.84 – INVLCA
Assembler found an invalid or undefined code address for the
procedure descriptor.
Error: An invalid or undefined code address corresponds to the
specified procedure descriptor.
User Action: Check your source code for the specified code
address.
22.85 – INVLISTOPT
You specified an invalid option with the .LIST or .SHOW directive.
Error: You specified an invalid option with the .LIST or .SHOW
directive.
User Action: See the descriptions of the .LIST and .SHOW
directives for valid .LIST and .SHOW options.
22.86 – INVLPD
Invalid procedure descriptor.
Error: You specified an invalid procedure descriptor. There was
no definition of a procedure descriptor by the specified name.
User Action: Check your source code.
22.87 – INVNLISTOPT
You specified an invalid option with the .NLIST or .NOSHOW
directive.
Error: You specified an invalid option with the .NLIST or .NO_
SHOW directive.
User Action: See the descriptions of the .NLIST and .NO_SHOW
directives for valid .NLIST and .NO_SHOW options.
22.88 – INVOFF
You attempted to specify data intialization with a current psect
offset that is outside the range of 0 to 2147483647.
Error: The current psect offset is invalid for specifying a data
initialization.
User Action: Check your source code and the value of the current
psect offset.
22.89 – INVREGNUMEXP
Invalid register-number expression. Specify an integer expression
between 0 and 31 or a previously defined or predefined register.
Error: You specified an illegal expression for a register symbol
definition.
User Action: Specify a value between 0 and 31. You can also
define a register in terms of a previously-defined or predefined
register.
22.90 – INVREPCOUNT
The integer value of the .REPEAT expression is not within the
inclusive range of 0 . . . 65535. A 0 value is assumed.
Warning: The value of the .REPEAT expression must be within the
range of 0 . . . 65,535, inclusive. Therefore, a 0 expression
value is assumed.
User Action: Specify a repetition count between 0 and 65,535,
inclusive.
22.91 – INVSAVEOPT
You specified an invalid option with the .SAVE_PSECT directive.
Error: You specified an invalid option with the .SAVE_PSECT
directive.
User Action: See the description of the .SAVE_PSECT directive for
valid .SAVE_PSECT options.
22.92 – INVTEMPLAB
Invalid use of temporary label.
Error: A temporary label reference is not allowed in this
context.
User Action: See Chapter 2 in the Reference Manual for
information about using temporary labels.
22.93 – INVTERM
Assembler found N when expecting a valid expression term.
Error: The assembler found an unexpected item where it expected
one of the following expressions: floating-point number, integer,
register, decimal point (.), identifier, or left-angle bracket
(<).
User Action: Check the item flagged by the assembler.
22.94 – IREGDEF
You cannot define an integer register in terms of a floating-point
register.
Warning: You are attempting to define an integer register symbol
in terms of a floating-point register. IREGDEF
User Action: Specify either an integer register or an expression
within the range of 0 to 31 with the .DEFINE_IREG directive.
22.95 – LABELNOTDEF
Undefined label.
Error: The label you specified is undefined.
User Action: See Chapters 2 and 4 for descriptions of the valid
labels.
22.96 – LABELREDECL
Illegal redefinition of label.
Error: You have illegally defined this label in multiple places
in this assembly unit.
User Action: Check all references to this label in your source
code.
22.97 – LABNOTINPSECT
Label must be declared in a PSECT.
Error: You are attempting to declare a temporary, local, or
global label without first establishing a psect.
User Action: Make sure you enter the appropriate .PSECT directive
before declaring the label in your source stream.
22.98 – LEXOPEDITSPEC
Unrecognized edit specifier.
Error: The assembler does not recognize the edit specifier for
the %EDIT lexical operator.
User Action: Check your source code and see the description of
the %EDIT lexical operator.
22.99 – LEXOPENDM
Illegal modification of .ENDM directive keyword by lexical
operation.
Error: While your macro definition contains a .ENDM directive
that ends the macro definition, the .ENDM directive is modified
by a lexical operator so that it can no longer be recognized as a
.ENDM directive keyword after lexical processing.
User Action: Change the statement to avoid modifying the .ENDM
directive keyword with lexical operator processing. See Chapter
3 in the Reference Manual for information about using lexical
operators.
22.100 – LEXOPENDR
Illegal modification of .ENDR directive keyword by lexical
operation.
Error: While your repeat range contains a .ENDR directive that
ends the repeat block, the .ENDR directive is modified by a
lexical operator so that it can no longer be recognized as a
.ENDR directive keyword after lexical processing.
User Action: Change the statement to avoid modifying the .ENDR
directive keyword with lexical operator processing. See Chapter
3 in the Reference Manual for information about using lexical
operators.
22.101 – LEXOPSYNTAX
Illegal lexical operator syntax (missing left or right parenthesis,
missing comma, or other lexical operator syntax error).
Error: The indicated lexical operator has a syntax error.
User Action: Check the source code to insure correct syntax.
22.102 – LEXSYM
XXXXX is already a lexical string symbol name; it cannot also be a
numeric symbol name.
Error: You cannot define a lexical string symbol and a numeric
symbol by the same name.
User Action: Check your source code and remove either the lexical
string or the numeric symbol definition.
22.103 – LIBMOD_BADFORMAT
Library module XXXXX contains illegal syntax (missing .MACRO or
label preceding .MACRO, missing or not matching .ENDM, or other
macro syntax error).
Error: The assembler encountered illegal syntax.
User Action: Check the syntax of the macro.
22.104 – LIBMOD_EMPTY
Library module XXXXX is empty.
Warning: The assembler encountered an empty library module.
User Action: Replace the library module.
22.105 – LIBMOD_EXTRA
Library module XXXXX contains extraneous text after .ENDM; the
assembler ignores the extra text.
Warning: The assembler encountered extraneous text after an .ENDM
directive in a library module. The assembler ignores this text.
User Action: Correct the library module.
22.106 – LIBMOD_NOT_FOUND
Library module XXXXX not found.
Error: The assembler could not find the indicated library module.
User Action: Check the spelling of the macro library and module
names.
22.107 – LOCCTRNOTDATA
Location counter cannot be set in a psect with the EXE and NOMIX
attributes.
Error: You cannot modify the location counter in a psect with the
EXE and NOMIX attributes.
User Action: If you need to modify the location counter, specify
the MIX psect attribute. See Chapter 5 iin the Reference Manual
for a description of the MIX psect attribute.
22.108 – MACCASEMATCH
Library macro name is spelled using different alphabetic case than
in .MCALL directive or macro invocation.
Error: There is an alphabetic case difference between that
specified in the macro library and what you specified for the
macro name.
User Action: Check the case of the macro name in your source code
and the case of the macro in the specified macro library.
22.109 – MACEXPNEST
Macro expansion exceeds maximum nesting depth (macro recursion not
detected).
Error: The macro is not recursive but exceeds the maximum
allowable expansion depth.
User Action: Check your source code for possible restructuring.
22.110 – MACPARAMGENDEF
You can specify a generated label default value or a default string
value, but not both.
Error: You specified both a default string value and a generated
label default value when you can only specify one.
User Action: Examine your source code.
22.111 – MACPARAMSYNTAX
Illegal macro parameter syntax. Assembler found XXXXX when expecting
one of XXXXX.
Error: Macro parameter syntax is invalid.
User Action: Try replacing the unexpected argument with one of
those items cited as expected.
22.112 – MACRECURSE
Recursive macro exceeds maximum macro expansion nesting depth.
Error: The macro is recursive and exceeds the maximum expansion
nesting depth.
User Action: Check your source code for a missing basis step in
the recursive macro.
22.113 – MACZERO
Assembler cannot evaluate expression. A 0 expression value is
assumed.
Informational: The assembler cannot evaluate this expression due
to errors it encountered. Therefore, a 0 value is assumed.
User Action: Check the expression for forward or external
references.
22.114 – MAXIF
Maximum nesting of .IF directives exceeded.
Error: The maximum depth nesting of .IF directives has been
exceeded.
User Action: Check your source code for possible restructuring.
22.115 – MAXLEXOP
More than N lexical operators encountered; check for a recursive
lexical string symbol.
Error: Your source line contains an excessive number of lexical
operators. A recursive lexical string symbol definition occurs
when you initially define a lexical string symbol in terms
of itself using the lexical substitution operator. While the
assembler normally interprets lexical substitution operators
during lexical string symbol definition, it cannot in this case
because the lexical string symbol is not yet defined. When the
assembler later expands such a lexical string symbol with the
imbedded self reference, infinite recursion results.
User Action: Check your source code for recursive lexical string
symbol definitions and redefine them to avoid recursion.
22.116 – MISSENDC
Missing .ENDC directive(s).
Warning: The assembler could not find a terminating .ENDC
conditional directive.
User Action: Check your source code.
22.117 – MISSINGENDM
Missing .ENDM directive.
Error: The assembler could not find a terminating .ENDM directive
to match a .MACRO directive.
User Action: Check your source code.
22.118 – MISSINGENDR
Missing .ENDR directive.
Error: The assembler could not find an .ENDR directive to
terminate an .IRP or a.REPEAT block.
User Action: Check your source code.
22.119 – MISSQUOTE
Missing closing double-quote character in string literal.
Error: The closing double-quote is missing from the string
literal.
User Action: Check your source code and insert a closing double-
quote for a string literal.
22.120 – MODCODLOCCTR
Restoring the location counter in the current context causes an
illegal modification of the location counter for a psect with the
EXE and NOMIX attributes.
Error: You cannot modify the location counter in a psect with the
EXE and NOMIX attributes.
User Action: If you need to modify the location counter, specify
the MIX psect attribute. See Chapter 5 in the Reference Manual
for a description of the MIX psect attribute.
22.121 – NOBEGEX
Assembler encountered an unmatched .END_EXACT directive.
Error: The assembler encountered an .END_EXACT directive before a
.BEGIN_EXACT directive.
User Action: Check your source code.
22.122 – NOCA
You did not specify a code address as argument 2 with
.PROCEDURE_DESCRIPTOR.
Error: You did not specify a code address as the second argument
to the .PROCEDURE_DESCRIPTOR directive.
User Action: The code address must be a nontemporary label
defined in a psect with the EXE or NOMIX attribute. Check your
source code.
22.123 – NOQUAL
Instruction qualifiers are invalid with this opcode.
Error: You cannot specify instruction qualifiers with this
opcode.
User Action: See Appendix A in the Reference Manual for a
complete list of opcodes and valid instruction qualifiers.
22.124 – NOTAQUAL
An item you specified in the qualifier list is invalid with this
opcode.
Error: The instruction qualifier you specified with the opcode is
invalid.
User Action: See Appendix A in the Reference Manual for a
complete list of opcodes and valid instruction qualifiers.
22.125 – NOTENOUGHARGS
Not enough arguments for instruction.
Error: The instruction needs one or more additional arguments.
User Action: Check the argument numbers and required formats as
specified in Chapter 5 in the Reference Manual.
22.126 – NOTINMACRO
This statement must occur only within a macro.
Error: The statement you specified is only allowed within a
macro.
User Action: See Chapter 2 in the Reference Manual for a
description of the statement specified.
22.127 – NOTINSEM
Missing functionality in SEM.
Error: This functionality is missing in the assembler.
User Action: Please report the problem to Digital.
22.128 – NUMSYM
XXXXX is already a numeric symbol name; it cannot also be a lexical
string symbol name.
Error: You cannot define a numeric symbol and a lexical string
symbol by the same name.
User Action: Check your source code and remove either the numeric
or the lexical string symbol definition.
22.129 – OPTIGN
The assembler is ignoring one or more VAX MACRO options.
Informational: The assembler detected and ignored a VAX MACRO
option.
User Action: Remove the VAX MACRO options from your MACRO-64
Assembler for OpenVMS Alpha Systems program.
22.130 – OVERLAP
Assembler detected overlapping initializers at offset NN. This
initial value overlaps but is not an exact replacement for a
previous initial value.
Error: You are trying to assign or initialize multiple values to
the same location. This is not allowed.
User Action: Check your source code.
22.131 – PSECTALIGNCON
PSECT alignment conflicts with earlier declaration.
Error: A previously specified psect alignment attribute conflicts
with the flagged psect attribute.
User Action: Check all declarations of the psect. See the
description of the .PSECT directive and psect attributes.
22.132 – PSECTATTRCON
PSECT attribute conflicts with earlier declaration.
Error: A previously specified psect attribute conflicts with the
flagged psect attribute.
User Action: Check all declarations of the psect. See the
description of the .PSECT directive and psect attributes.
22.133 – REGREDEF
You attempted to redefine a previously defined register symbol with
a different value.
Warning: You are attempting to change the definition of a
register symbol that either you have previously defined or that
MACRO-64 has predefined.
User Action: Check for conflicts with the register-symbol
identifier you have specified. If you wish to redefine a register
symbol, you must first cancel its previous definition with the
.UNDEFINE_REG directive.
22.134 – REDUNDELSE
You cannot specify more than one .ELSE directive within a single .IF
block.
Error: The assembler encountered more than one .ELSE directive
within a single .IF block.
User Action: Check your source code.
22.135 – RESTOREWOSAVE
PSECT .RESTORE without .SAVE.
Error: You entered a .RESTORE_PSECT directive without a previous
corresponding .SAVE_PSECT directive.
User Action: Check the uses of .SAVE_PSECT and .RESTORE_PSECT in
your source code.
22.136 – SAVESTACKOVER
Internal SEM PSECT .SAVE stack overflow.
Fatal: An internal error has occurred.
User Action: Gather as much information as possible about the
circumstances under which the error occurred and report the
problem to Digital.
22.137 – SRCREAD
Error reading source file.
Error: The assembler encountered an error in reading your source
file.
User Action: Check file specifications, protections, and so
forth.
22.138 – SYMBOLREDECL
Illegal redefinition of symbol.
Error: The symbol is already defined as a label or explicitly
declared as externally defined with the .EXTERNAL directive.
User Action: Check all uses of this symbol.
22.139 – TOOMANYARGS
Too many arguments for instruction.
Error: The instruction contains one or more arguments than
necessary.
User Action: Check the argument numbers and required formats as
specified in Chapter 5 in the Reference Manual.
22.140 – TOOMANYMACARG
You specified more arguments than are defined for this macro.
Error: You specified more arguments on the macro call than were
specified for its definition.
User Action: Check the macro definition and point of call in your
source code.
22.141 – TOOMANYMACPARAMS
Too many macro parameters.
Error: You specified too many macro parameters.
User Action: Check your source code.
22.142 – TRUNCDATA
Data truncation warning.
Warning: You specified a data value that is out of range for the
specified directive, which results in data truncation.
User Action: Specify a smaller value.
22.143 – UNDCA
You specified an undefined code address with the procedure
descriptor.
Error: The code address you specified as the second argument to
the .PROCEDURE_DESCRIPTOR directive is undefined.
User Action: The code address must be a nontemporary label
defined in a psect with the EXE or NOMIX attribute. Check your
source code.
22.144 – UNDEFSYM
Undefined symbol or label. Assembler assumes an .EXTERNAL
definition.
Warning: The referenced label or symbol does not have an explicit
definition and an external definition is assumed.
User Action: Use the .EXTERNAL directive to declare the symbol.
22.145 – UNEXPELSE
Unexpected .ELSE directive.
Error: The assembler encountered an unexpected .ELSE directive.
User Action: Check the use of the .ELSE directive in your source
code to insure proper positioning with a .IF and .ENDC directive.
22.146 – UNEXPENDC
Unexpected .ENDC directive.
Error: The assembler could not find a terminating .ENDC for a
macro conditional directive, such as .IF.
User Action: Check your source code.
22.147 – UNEXPENDM
Unexpected .ENDM directive.
Error: The assembler encountered an unexpected .ENDM directive.
User Action: Check your source code for matching .MACRO/.ENDM
pairs.
22.148 – UNEXPENDR
Unexpected .ENDR directive.
Error: The assembler encountered an unexpected .ENDR directive.
User Action: Check your source code for matching .REPEAT/.ENDR
and .IRP/.ENDR directive pairs.
22.149 – UNEXPIFF
Unexpected .IF_FALSE (.IFF) directive.
Error: The assembler encountered an unexpected .IF_FALSE
directive.
User Action: Check your source code to insure that this directive
occurs within an .IF block.
22.150 – UNEXPIFT
Unexpected .IF_TRUE (.IFT) directive.
Error: The assembler encountered an unexpected .IF_TRUE
directive.
User Action: Check your source code to insure that this directive
occurs within an .IF block.
22.151 – UNEXPIFTF
Unexpected .IF_TRUE_FALSE (.IFTF) directive.
Error: The assembler encountered an unexpected .IF_TRUE_FALSE
directive.
User Action: Check your source code to insure that this directive
occurs within an .IF block.
22.152 – UNEXPMEXIT
Unexpected .MEXIT directive.
Error: The assembler encountered an unexpected .MEXIT directive.
User Action: Check your source code.
22.153 – UNKDIR
Assembler found unknown directive XXXXX.
Error: An internal error has occured.
User Action: Gather as much information as possible about the
circumstances under which the error occurred and report the
problem to Digital.
22.154 – UNKENDISOPTION
You specified an unknown .ENABLE/.DISABLE option.
Error: The option you specified for .ENABLE/.DISABLE is
incorrect.
User Action: Check the option specified with the .ENABLE/.DISABLE
directive.
22.155 – UNKNOWNATTR
Unknown PSECT attribute.
Error: The assembler does not recognize the specified psect
attribute.
User Action: See the description of the .PSECT directive and
psect attributes.
22.156 – UNTERMEX
Assembler detected N unterminated .BEGIN_EXACT directive(s) in psect
XXXXX.
Error: Unmatched .BEGIN_EXACT directive(s) occur for the
indicated psect.
User Action: Check your source code.
22.157 – VAXDIR
The assembler is ignoring one or more VAX MACRO directives or
options. Assembler continues processing with the next line.
Informational: The assembler detected and ignored a VAX MACRO
directive or option.
User Action: Remove the VAX MACRO directives from your MACRO-64
Assembler for OpenVMS Alpha Systems program.
22.158 – VMACELSE
You cannot specify .ELSE in the same .IF block with either .IF_FALSE
(.IFF), .IF_TRUE (.IFT), or .IF_TRUE_FALSE (.IFTF).
Error: The assembler encountered an .ELSE directive within the
same .IF block as an .IF_FALSE, .IF_TRUE, or .IF_FALSE directive.
User Action: Check your source code and remove either the .ELSE
directive or the .IF_x directive.
22.159 – WRONGMACID
Macro name in .ENDM does not match corresponding .MACRO.
Error: The macro name you specified as the optional argument to
the .ENDM directive does not match the name you specified with
the corresponding .MACRO directive.
User Action: Check your souce code for matching .MACRO/.ENDM
directive pairs.
22.160 – WRONGPL
The code address you specify with the .PROCEDURE_DESCRIPTOR
directive must occur BEFORE its definition as a local or global
label.
Error: The code address you specify as the second argument to the
.PROCEDURE_DESCRIPTOR directive must occur before its definition
as a nontemporary label defined in a psect with the EXE or NOMIX
attribute.
User Action: Check your source code.
23 – Example Location
When you install MACRO-64 from the Freeware CD, a number of
MACRO-64 examples are placed in the SYS$EXAMPLES directory.
To find these examples, enter the following command at the
DCL prompt:
$ DIRECTORY SYS$EXAMPLES:MACRO64$*.M64