An Event Dispatcher Outbound Stream entity represents an outgoing connection to a sink on a local or remote node. An Outbound Stream entity manages the connection to the sink, and it filters, processes, and transmits events to the sink.
1 – character
CATCH ALL FILTER Default: Pass Value: Pass or Block Action to take if neither the specific filter nor the global filter contains an entry that matches an event. PASS - Report the event. BLOCK - Discard the event. CONNECT RETRY TIMER Default: 120 Value: 0-65535 Number of seconds to wait after a disconnect or connection reject before reattempting a connection. Connection attempts continue until a connection is made or until the connect timer enabled attribute is set to false or the Outbound Stream is disabled. If the Outbound Stream is already connected to the sink when the timer expires, no connection is attempted at that time. The timer resets and connection attempts continue whenever the timer expires. ENABLE CONNECT TIMER Default: True Value: True or False Specifies whether the connect timer is operational see connect retry timer. DISCONNECT TIMER Default: 0 Value: 0-4294967295 Number of seconds to wait before disconnecting an idle connection. Zero indicates that there is no disconnect timer and connections are never automatically disconnected. SINK END USER Default: Number=82 Value: end-user-specification Sink session control end user specification for this stream. SINK NODE Default: Local Node Value: Full-name Full DNS node name of the sink for this stream. Modifying this characteristic affects only subsequent connect requests; existing connections are unaffected. This fullname is used in combination with the sink end user characteristic to establish the sink connection. SINK OBJECT Default: No Sink Object Value: Full-name Full DNS object name of the sink for this stream. Modifying this characteristic affects only subsequent connect requests; existing connections are unaffected. This fullname should match the object name characteristic of the target sink.
2 – counters
CONFIDENCE CHANGES Number of times the confidence variable has changed while connections were in the open state. CONNECT REQUESTS Number of times a connection to a remote node was requested by this stream, either by an explicit command or by the connection timer. CONNECTIONS ACCEPTED Number of times an outbound connection request was accepted by the sink partner. DISABLED Number of disable events for this stream. ENABLED Number of enable events for this stream. EVENTS LOST Number of events lost because of Outbound Stream buffer overrun. FILTER CHANGES Number of times the filter has changed. SHUTDOWNS Number of times a shutdown command or operation was issued.
3 – status
BUFFER SIZE Maximum number of octets allowed for event processing of this stream. This value is defined in the create command for the stream. STATE Status of the Outbound Stream. OFF - The stream is disabled. ON - The stream is enabled. ONCONNECTED - The stream is enabled and has an established connection. ONCONNECTING - The stream is enabled and is in the process of establishing a connection. ONDISCONNECTING - The stream is enabled, but is in the process of disconnecting from a connection. ONSHUTDOWNREQUESTED - The stream is enabled and has an established connection, but is in the process of shutting down; the stream will disconnect after it transmits all events that were outstanding when the shutdown command was issued.