NCLHELP.HLB  —  SNA Peer Server Module, QLLC  Link Station subentity, show  Characteristics
   Usage Type      outgoing |    Displays the type of connections that
                   incoming |    can run over this station. If set to
                   both          incoming, then only IBM initiated X.25
                                 connections are allowed. If set to
                                 outgoing, then the Peer Server will
                                 initiate connections. If set to both
                                 then either end can initiate
                                 connections.

   Retry Maximum   (0-255)       Displays the maximum number of times
                                 to retry when an error occurs.

   Retry Timeout   (1-600)       Displays the time in seconds to wait
                                 between retries.

   Contact         yes | no      Displays whether the secondary station
   Terminal                      awaits receipt of a QRR command or of
                                 the first data frame before establish-
                                 ment of the link connection is
                                 acknowledged.

   Capability      primary |     Displays the capability of the Station
                   secondary|    subentities of this Link entity.
                   negotiable    Negotiable stations can become either
                                 primary or secondary.

   Call User Data  2 chars       Displays the hexadecimal string that
                   (hexa-        identifies the type of X.25 to be made
                   decimal)      to create a QLLC connection.

   Remote DTE      DTEaddress    Displays the X.25 DTE address of the
   Address                       remote station. If the Peer Server
                                 initiates the connection, this is the
                                 address that will be called. For an IBM
                                 initiated connection, if the Usage Type
                                 parameter is set to Incoming, this
                                 address will be matched against the
                                 caller's address and if not matched,
                                 the call will be rejected.

   Maximum BTU     (128-4095)    Displays the size that SNA messages
   Size                          will be segmented into before being
                                 sent to the X.25 network. (The X.25
                                 network may further segment packets
                                 based on the level 2 profile
                                 information being used.)