show [node node-id] fddi - station station-name - phy port port-index attribute [,attribute...] all [attributes] all characteristics all counters all identifiers all status The station-name must be a simple name which uniquely identifies a particular station instance. The port-index can be either an integer or a wildcard. OpenVMS Examples: show fddi station fddi-0 phy port * all show fddi station fddi-0 phy port 0 all Tru64 UNIX Examples: show fddi station fddi-1 phy port * all show fddi station fddi-1 phy port 1 all
1 – Characteristics
o lem threshold Value: For n, 10 to the -n th power Link error monitor threshold. o phy type Type of the physical port (A, B, S, or M). This characteristic cannot be set. o pmd type Type of the PDM (transceiver) for this physical port. This characteristic cannot be set. ANSI multimode Low power ANSI multimode type 1 Thinwire ANSI single mode type 2 Shielded twisted-pair ANSI SONET Unshielded twisted-pair
2 – Counters
o creation time Time at which the port was created. o connections completed Number of times the PHY port entered the in use state, having completed the initialization process. o elasticity buffer errors Number of times the elasticity buffer function had an overflow or underflow. o lct rejects Number of times a connection was rejected due to failure of the Link Confidence Test at either end of the physical connection. o lem rejects Number of times an active connection was disconnected due to rejection by the Link Error Monitor at this end of the physical connection, or by expiration of the Noise timer. o link errors Total number of raw link error input events seen by the Link Error Monitor.
3 – Identifier
o index An integer that uniquely identifies this physical port to the parent station entity.
4 – Status
o broken reason Reason phy port is in broken state, or if in broken state, none. o estimated link error rate Default: 15 Value: 0-15 Reports the number of errors during the Link Monitor Test as a negative power of 10. If there are no errors during the Link Monitor Test, then the Estimated Link Error Rate is 10(-15th power). An Estimated Link Error Rate of 15 indicates an excellent/clear link, 14-10 is a noisy link and around 7 would indicate an acceptable (failed) link. o neighbor phy type Status may be A, B, S, M or unknown. o reject reason Reason the phy port is in a failed or watch state. This is not meaningful when phy port is in some other state. LCT both Link Confidence Test failed on both sides of the sides physical connection. LCT protocol Neighboring physical port has been detected to error have prematurely exited the link confidence test (LCT). LEM reject Link error monitor disconnected this connection due to the error rate exceeding the LEM threshold. local LCT Link Confidence Test failed on this end of the physical connection. noise reject Noise timer expired because a single noise event lasted for more than 1.31072 ms. none No reason. remote LCT Link Confidence Test failed on the other end of the physical connection. remote Neighboring physical port broke the connection for reject an unknown reason. standby Physical port and its neighboring physical port form a redundant physical connection (dual- homing feature). In a dual-homed configuration, the B to M connection is the higher priority physical connection, and the A to M connection is the standby physical connection. The standby connection will become active if the B to M connection is lost. topology Neighboring physical port's physical port type is reason an illegal match for this physical port's physical port type. trace in Physical port was initializing when a pc-trace progress occurred. When a pc-trace occurs, any physical ports that have not yet established a physical connection are shut down to prevent the topology from changing. trace Physical port was momentarily disabled because it received- received a pc-trace when its own pc-trace function disabled was disabled. The pc-trace function is enabled by default. The trace disable switch is not remotely manageable. o state Operational state of the phy port entity (nonsettable). broken The physical port has failed initialization tests and is not available for use. failed Same as waiting, except the physical port has failed to complete the last connection attempt. Refer to the physical port's status parameter reject reason for the reason for connection failure. Connection attempts will continue until successful. internal The physical port has been configured to loopback internally present all transmitted symbols to the receive interface. The network connector is inactive. This allows internally generated test frames to be looped back for test purposes. in use The physical port has established a connection and is fully operational. Communications services are now available. off-ready The physical port is waiting to be enabled or has been disabled by management request. starting The physical port has received a response from the neighboring physical port and is exchanging information and performing the link confidence test (LCT) prior to completing the connection. waiting The physical port is beginning to establish a connection and is waiting for a response from the neighboring physical port. watch Same as starting, except the physical port has failed to complete the last connection attempt. Refer to the physical port's status parameter, reject reason for the reason for connection failure. Connection attempts will continue until successful. o uid Entity's unique identifier, which is generated when the entity is created.