1 INTERRUPT Invokes an interrupt test. 2 GENERAL QUALIFIERS /NODENAME /NODENAME=node-id Identifies the node (by name or address) on which DTR is to run. The default is the local node. DTR runs on the default nonprivileged account on the remote node because access control information cannot be used as part of the node name. To run DTR on an account other than the default, you must create a new account and associate it with the DTR object. /PRINT /PRINT /NOPRINT (D) Instructs DTS to print (or log) test results. The default is /NOPRINT. /STATISTICS /STATISTICS (D) /NOSTATISTICS Instructs DTS to print statistics on data and interrupt tests. The default is /STATISTICS. /DISPLAY /DISPLAY=number /NODISPLAY (D) Instructs DTS to print the specified number of bytes (in hexadecimal) of data and interrupt messages transmitted to DTR. The default is /NODISPLAY. /SPEED /SPEED=number Indicates the line speed (bits per second) of the test line. DTS uses this qualifier for reporting statistics (DTS does not control line speeds). The default number is 1000000. 2 COMMAND-SPECIFIC QUALIFIERS /TYPE /TYPE=test-type Indicates the subtest for the interrupt test. There are four subtests: SINK Indicates a sink test. The default test type. SEQ Indicates a sequence test. PAT Indicates a pattern test. ECHO Indicates an echo test. /SIZE /SIZE=number Indicates the data message length in bytes. The lower bounds are 0 for a sink or echo test; 4 for a sequence test; and 5 for a pattern test. The upper bound is 16 bytes for all tests. The default size is 16. /[TEST-DURATION] /[TEST-DURATION] Indicates the duration of the test. There are three units of time for this parameter: /SECONDS=number /MINUTES=number /HOURS=number The number specifies the duration of the test. The default unit is /SECONDS=30. The maximum test duration is 3,600,000 seconds or 1000 hours. 2 Example -Test: INTERRUPT/NODENAME=DALLAS/PRINT/TYPE=PAT/SIZE=16 _DTS-S-NORMAL, normal successful completion Test parameters: Test duration (sec) 30 Target nodemane "DALLAS" Linespeed (baud) 1000000 Message size (bytes) 16 Summary statistics: Total messages XMIT 2734 RECV 0 Total bytes XMIT 43744 Messages per second 91.1 Bytes per seconds 1458 Line throughput (baud) 11665 - Line utilization 1.1 This command invokes the interrupt test with the pattern subtest. DTS sends interrupt messages to DTR on node DALLAS where test information is to be printed. The interrupt message size is 16 bytes, and the test is 30 seconds (by default).